Literature DB >> 3180948

Identification of inflammatory cells in bovine milk by flow cytometry.

D Redelman1, S Butler, J Robison, D Garner.   

Abstract

Cells recovered from normal or mastitic bovine milk were examined by flow cytometry. All milk samples contained particulate material that was heterogeneous in size and that produced a right-angle light-scatter signal equal to or greater than that produced by human or bovine neutrophils. Although this material labeled with Hoechst 33342, it produced fluorescence intensities below that of intact bovine cells, suggesting that it consisted of cell fragments. Mastitic milk additionally contained other populations of cells that were poorly resolved from the normal particulate material by size (electronic volume sensor) and right-angle light scatter. In order to improve this resolution, the milk cells were incubated with carboxydimethylfluorescein diacetate (CMFDA) to label intact cells. When milk samples labeled with CMFDA were examined by dual-parameter analysis using green fluorescence and right-angle light scatter, five or more populations of cells could be identified in mastitic milk. These populations included intact and degenerate neutrophils, lymphocytes, including both small and activated cells, monocytes, and large activated macrophages containing many vacuoles and phagocytosed particles. Using this procedure, all the animals in the University of Nevada-Reno Holstein dairy herd were tested once a month for 6 months. In addition, individual animals with mastitis were examined one or more times each day during the course of the inflammatory process. In the routine screening, the flow cytometric examination detected mastitis before overt symptoms developed. In cows identified to have mastitis, the flow cytometric examination provided prognostic information regarding the success of treatments.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3180948     DOI: 10.1002/cyto.990090510

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  2 in total

1.  Properties of human blood monocytes. I. CD91 expression and log orthogonal light scatter provide a robust method to identify monocytes that is more accurate than CD14 expression.

Authors:  Dorothy Hudig; Kenneth W Hunter; W John Diamond; Doug Redelman
Journal:  Cytometry B Clin Cytom       Date:  2013-10-08       Impact factor: 3.058

2.  Is there a special mechanism behind the changes in somatic cell and polymorphonuclear leukocyte counts, and composition of milk after a single prolonged milking interval in cows?

Authors:  Branislav Lakic; Ewa Wredle; Kerstin Svennersten-Sjaunja; Karin Ostensson
Journal:  Acta Vet Scand       Date:  2009-01-15       Impact factor: 1.695

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.