Literature DB >> 31805080

Limits in reliability of leg-spring and joint stiffness measures during single-leg hopping within a sled-based system.

David Diggin1, Ross Anderson2, Andrew J Harrison2.   

Abstract

Research examining the reliability of stiffness measures during hopping has shown strong consistency in leg-spring stiffness (kleg), but high variability in joint stiffness (kjoint) measures. Sled-based systems (SBS) reduce movement degrees-of-freedom and are used to examine stretch-shortening cycle (SSC) function under controlled conditions. The aim of this study was to examine the reliability of kleg and kjoint during single-leg hopping within an SBSKinematic and kinetic data were collected on four occasions (Day_1, Day_2, Day_3 and Day_3Offset). Participants completed two trials of single-leg hopping at different frequencies (1.5, 2.2 and 3.0 Hz) while attached to an inclined-SBS. Stiffness was determined using models of leg-spring (kleg) and torsional (kjoint) stiffness. Statistical analysis identified absolute and relative measures of reliability. Results showed moderate reliability for kleg at 1.5 Hz between inter-day testing bouts, and weak consistency at 2.2 and 3.0 Hz. Examination of intra-day comparisons showed weak agreement for repeated measures of kleg at 1.5 and 2.2 Hz, but moderate agreement at 3.0 Hz. Limits in kleg reliability were accompanied by weak-to-moderate agreement in kjoint measures across inter- and intra-day testing bouts. Results showed limits in the reliability of stiffness measures relative to previous reports on overground hopping. Lack of consistency in kleg and kjoint may be due to the novelty of hopping within the current inclined-SBS. Constraints imposed on the hopping task resulting from SBS design (e.g. additional chair mass, restricting upper body movement) may have also influenced limits in kleg and kjoint reliability. Researchers should consider these findings when employing inclined-SBS of a similar design to examine SSC function.

Entities:  

Year:  2019        PMID: 31805080      PMCID: PMC6894759          DOI: 10.1371/journal.pone.0225664

Source DB:  PubMed          Journal:  PLoS One        ISSN: 1932-6203            Impact factor:   3.240


Introduction

Stretch-shortening cycle (SSC) tasks are characterised by eccentric lengthening immediately followed by concentric shortening [1]. These actions are typical of human movement (e.g. walking, running, jumping and throwing) and serve to enhance concentric force output and movement efficiency [1,2]. Knowledge of mechanisms controlling SSC function are therefore relevant to general health and athletic performance. SSC function has subsequently been examined during walking [3], running [4,5], jumping [4], under fatigued conditions [6-10] and before and after training [11,12]. It is understood that the efficiency of SSC task performance is regulated by a combination of elastic and neural mechanisms [1]. Of importance to elastic mechanisms of SSC performance is the property stiffness (k). Stiffness represents the resistance of a body to deformation and reflects the elastic nature of the body [13,14]. In humans, greater stiffness is found to enhance the operational effectiveness of the SSC [15-17], yet higher levels of stiffness also contribute to musculoskeletal injury [18]. When examining stiffness characteristics during SSC tasks, researchers often model the elastic nature of the entire leg as a linear-spring (i.e. kleg) [9,19-22]. Torsional stiffness models are also used to clarify the contribution of the stiffness of each joint (kjoint) to kleg [7]. The reliability of kleg and kjoint measures has been examined during SSC tasks [22,23]. During double- and single-leg hopping, Joseph et al. [23] and Diggin et al. [22] showed good agreement (ICC > 0.80) for repeated measures of kleg when hopping frequency is controlled. In contrast, measurement consistency declined (ICC = 0.20–0.86) during running and hopping at self-selected frequencies [23]. Furthermore, kjoint measures have consistently demonstrated questionable reliability during natural hopping and running tasks. Joseph et al. [23] showed poor reliability for all kjoint variables measured (ICC = 0.51–0.92; CV > 20%). Diggin and colleagues [22] showed strong consistency for repeated measures of kankle, but weak-to-moderate agreement for kknee and khip (ICC = 0.57–0.93) during single-leg hopping. It must be noted that in efficient SSC tasks (e.g. hopping), participants must coordinate the body’s musculoskeletal structures (e.g. segments, muscles, joints) in an integrated fashion to achieve the movement goal. These requirements produce inherent variability in movement patterns which can impact movement consistency and measurement reliability [24]. It is possible that limits in kleg and kjoint reliability previously reported, were caused by extraneous movements (esp. upper body) that impacted landing consistency. Researchers have used sled-based systems (SBS) to offset issues associated with extraneous upper body movements [8,19,25,26]. While construction varies between laboratories, these systems often include rails positioned at angles below vertical orientation (e.g. 0°–30° to horizontal) [12,27]. A force plate mounted at the end of the system provides kinetic information of participants’ performance [6,25,28]. Participants perform SSC tasks (e.g. drop / rebound jumps, hopping) while attached to a chair / platform (sled) that slides up and down the inclined rails. SBS regulate levels of mechanical load experienced during SSC tasks by (i) altering rail angle [27]; (ii) employing a winch system to control initial eccentric loading [19,29]; and (iii) reducing movement degrees-of-freedom [10,30]. For lower body SBS, performance of SSC tasks while attached to the chair limits upper body movement and allows researchers to control impact velocities and eccentric loading [8,19]. Furthermore, the restricted path of the sledge chair might reduce task constraints and facilitate consistent landing patterns which can impact measurement reliability. The reliability of kinematic and kinetic variables measured during SSC task performance within an SBS has been examined. Debenham and colleagues [10] reported strong agreement (ICC = 0.87) for ankle joint range-of-motion recorded during single-leg hopping tasks within an SBS. During drop (DJ) and rebound jump (RBJ) tasks, Flanagan and Harrison [19] reported strong consistency (Cronbach’s α > 0.95) for temporal and kinetic variables tested (e.g. flight time, Fz max, reactive strength index). Similarly, during a simulated hopping task within an SBS, Furlong and Harrison [29] reported strong consistency (Cronbach’s α > 0.90) for temporal (CT, flight time) and kinetic (e.g. Fz max, peak rate of force development) variables. Flanagan and Harrison [19] reported strong reliability (Cronbach’s α > 0.95) for repeated measures of kleg during jumping tasks (Cronbach’s α > 0.95) within an SBS. Given the purpose of the SBS is to reduce extraneous upper body movement to encourage landing and measurement consistency, it is possible that stiffness measures (esp. kjoint) achieved during hopping within an SBS might demonstrate strong reliability. To date, the consistency of kleg and kjoint measures recorded during hopping within an SBS has not been examined. The aim of this study was to examine the reliability of stiffness measures during hopping within an inclined-SBS. It was hypothesized that restricting extraneous upper body movement would facilitate strong consistency for kleg and kjoint variables during hopping tasks.

Materials and methods

Participant characteristics

Thirty-two students (16 males and 16 females; mean ± SD age 21.3 ± 2.9 years; stature 1.70 ± 0.08 m; mass 69.9 ± 10.0 kg) volunteered to participate. Volunteers were recruited via e-mail circulated to the campus community. All participants were physically active as members of a university sports club, attending bi-weekly practices and represented the university at varsity level. Participants were injury free for at least six months prior to testing as determined via health screening questionnaire. Procedures were approved by the research ethics committee of the Faculty of Education and Health Science at the University of Limerick, and all participants provided written informed consent. To limit the effects of fatigue on stiffness measurement, participants were instructed to abstain from vigorous physical activity 24 hours before testing bouts.

Experimental procedures

Participants completed a familiarization session one week prior to initial testing to acquaint them with procedures (Day_0) [31]. Following this, participants underwent testing on four occasions. The first (Day_1), second (Day_2) and third (Day_3) testing bouts took place at the same time of day, spaced three to seven days apart [23,32]. On the final test day, participants completed procedures twice; at their typically scheduled time (Day_3) and six hours prior to or following their scheduled time (Day_3Offset) [22]. For each test, participants wore dark, tight-fitting clothing. Retro-reflective markers (14 mm) were placed at six anatomical locations on participants’ right side (acromion process, greater trochanter, lateral epicondyle of the femur, lateral malleolus, calcaneus and fifth metatarsal). Marker placement was conducted by the same tester throughout for consistency. During all test bouts (Day_0 –Day_3), participants completed two 10 second trials of single-leg hopping at each of 1.5, 2.2 and 3.0 Hz in time with a digital metronome (TempoPerfect Metronome, NCH Software, Greenwood Village, CO, USA) while secured within an SBS (Fig 1). The design of the SBS was described previously [12,19]. As previous research suggests little effect of leg dominance on kleg or kjoint [23], participants were instructed to land as close as possible to the force plate center (AMTI OR6-5; AMTI, Watertown, MA, USA) in time with the metronome, using their right leg and natural hopping technique. Trials were accepted for analysis if participants hopped within ± 5% of the target frequency [33,34]. The order of hopping trials was randomly assigned, and participants received 60 seconds recovery between each trial to limit fatigue effects. An analogue triggering device was used to initiate 3D kinematic and kinetic data acquisition simultaneously. Kinematic data were recorded using three MAC Eagle cameras (MotionAnalysis Corporation, Santa Rosa CA, USA) operating at 200 Hz. Kinetic data were recorded at 1 kHz over the 10 second duration.
Fig 1

Image showing the experimental set-up for hopping trials within the sled-based system.

Data processing

Analysis of data revealed an inconsistent delay in the initiation of kinematic and kinetic recordings. Whittlesey and Robertson [35] noted that kinematic and kinetic input signals must be temporally aligned to facilitate valid inverse dynamics analysis. Work in our laboratory has shown that maximum rate of change in fifth metatarsal marker acceleration profiles (i.e. peak jerk), coincide with ground contact to within 3.83 (± 1.06) ms of force plate criterion measures during overground hopping. Fifth metatarsal vertical coordinate data were subsequently differentiated to jerk [36]. The time of peak jerk was determined, and kinematic data were subsequently aligned with the time at which the vertical force increased above 5 N. Marker trajectories were digitized using Cortex motion analysis software (version 2.1; MotionAnalysis Corporation, Santa Rosa, CA, USA). 3D kinematic and kinetic data were subsequently exported and analyzed using customized MS Excel macros. Recorded kinematic and kinetic data were concurrently filtered using a fourth-order Butterworth Low-Pass digital filter with an optimal cut-off of 11 Hz determined via residual analysis [36]. 3D coordinate data were subsequently interpolated to 1 kHz using a cubic spline. Filtered kinematic and kinetic data were used to calculate resultant joint moments occurring about ankle (Mankle), knee (Mknee) and hip (Mhip) joints throughout the ground contact phase of each trial using inverse dynamics [7,23,37]. Segment inertia and mass characteristics were determined using the standards of Dempster [38]. Having calculated resultant moments, average torsional stiffness of the ankle (kankle), knee (kknee) and hip (khip) were calculated as a ratio of changes in joint moment (ΔMjoint) and angle (Δϴjoint) for respective lower limb joints [7,23]. In addition, kleg was recorded throughout the ground contact phase of all hopping trials using the spring-mass model [21]. Thus kleg was calculated as the ratio of Fz max and maximum leg compression (ΔLegL) occurring during ground contact as measured from video records [39], where leg length represented the distance between the greater trochanter and the center-of-force [40]. In all analyzed trials, the temporal occurrence of discrete events of Fz max and ΔLegL coincided to within 10% of the hop period.

Statistical analysis

The mean of 5 consecutive hops occurring within the middle of each 10-second trial was calculated for dependent variables and compared within and between experimental bouts. Differences between the means recorded for each experimental bout were established for each hopping frequency (HopFreq) using repeated measures ANOVA (parametric variables) or Friedman’s test (non-parametric variables). Reliability analysis employed both ‘absolute’ and ‘relative’ measures. A two-way random effects intra-class correlation coefficient (ICC) model examined the relative agreement between parametric and log-transformed dependent variables, while measurement consistency was established from effect size (ES) and ICC 95% confidence interval results [31,41,42]. Variables were considered strong when ICC ≥ 0.90 [43], the lower-bound level of the ICC 95% confidence interval (ICCLower) > 0.80 [31] and Cohen’s ES < 0.50 (moderate effect) [44]. Moderate reliability occurred if ICC ranged from 0.80 to 0.89, ICCLower ≥ 0.70 and ES < 0.50, while ‘weak’ reliability occurred if the previous criteria were not met. Within-participant variation in dependent variables were also examined using typical error (TE) [41], however these statistics were not included in reliability indexing. All statistical analysis was conducted using SPSS (version 23.0, IBM Corporation, Armonk, NY, USA).

Results

Results for control variables of contact time (CT; F (1.3, 3.9) = 2.14; p > 0.05), flight time (FT; F (1.7, 5.0) = 2.84; p > 0.05) and HopFreq (F (1.8, 5.3) = 0.56; p > 0.05; Table 1) revealed no significant difference between means for these variables across inter-day testing bouts. Reliability analysis showed strong agreement for variables of CT and FT (ICC = 0.95–0.97; ICCLower = 0.81–0.92; ES = 0.01–0.09) at 1.5 and 3.0 Hz with moderate reliability evident at 2.2 Hz (ICC = 0.94; ICCLower = 0.79–0.92; ES = 0.10). Across intra-day testing bouts, analysis revealed no significant difference in CT (F (2, 18) = 0.10; p > 0.05), FT (F (2, 18) = 0.29; p > 0.05) and HopFreq (F (1.6, 43.6) = 1.24; p > 0.05) when measured six-hours apart. The high ICC’s (0.92–0.98), moderate-to-high ICCLower coefficients (0.82–0.96) and low ES (0.04–0.13), suggest ‘strong’ intra-day agreement for variables of FT and CT. Despite moderate-to-strong reliability indices for FT and CT variables, HopFreq exhibited weak consistency throughout.
Table 1

Descriptive and reliability statistics (mean ± s) for control variables of CT, FT, and HopFreq recorded between inter- and intra-day testing bouts during hopping within a SBS.

Inter-day Comparisons
Mean (± s)ICCICC 95% CITEESIndex
VariablesDay_1Day_2Day_3LowerUpper
1.5 Hz
 CT (s)0.529 (0.063)0.539 (0.052)0.524 (0.060)0.9660.9180.9900.0160.058Strong
 FT (s)0.136 (0.064)0.127 (0.054)0.142 (0.060)0.9650.9180.9900.0150.070Strong
 HopFreq (Hz)1.50 (0.02)1.50 (0.01)1.50 (0.02)0.6810.4680.8300.020.12Weak
2.2 Hz
 CT (s)0.370 (0.029)0.377 (0.025)0.367 (0.020)0.9420.8080.9930.0110.090Strong
 FT (s)0.083 (0.027)0.077 (0.026)0.087 (0.021)0.9380.7940.9930.0110.096Moderate
 HopFreq (Hz)2.21 (0.03)2.21 (0.02)2.21 (0.02)0.7320.5430.8600.020.03Weak
3.0 Hz
 CT (s)0.274 (0.013)0.274 (0.013)0.274 (0.013)0.9490.8720.9870.0060.006Strong
 FT (s)0.059 (0.014)0.059 (0.013)0.060 (0.012)0.9480.8680.9870.0060.032Strong
 HopFreq (Hz)3.01 (0.04)3.00 (0.03)3.00 (0.03)0.7210.5410.8470.030.07Weak
Intra-day Comparisons
Mean (± s)ICCICC 95% CITEESIndex
VariablesDay_3Day_3OffsetLowerUpper
1.5 Hz
 CT (s)0.524 (0.060)0.516 (0.073)0.9700.9350.9880.0140.080Strong
 FT (s)0.142 (0.060)0.151 (0.074)0.9690.9350.9880.0110.086Strong
 HopFreq (Hz)1.50 (0.02)1.51 (0.02)0.7730.6060.8800.020.28Weak
2.2 Hz
 CT (s)0.367 (0.021)0.360 (0.029)0.9810.9590.9930.0070.083Strong
 FT (s)0.087 (0.021)0.093 (0.029)0.9820.9610.9940.0070.077Strong
 HopFreq (Hz)2.21 (0.02)2.20 (0.03)0.7400.5440.8650.020.08Weak
3.0 Hz
 CT (s)0.274 (0.013)0.275 (0.013)0.9210.8270.9700.0060.131Strong
 FT (s)0.06 (0.012)0.059 (0.011)0.9160.8180.9690.0070.044Strong
 HopFreq (Hz)3.00 (0.03)2.99 (0.04)0.7360.5420.8610.030.31Weak

Abbreviations: CT = contact time; FT = flight time; HopFreq = hopping frequency; ICC = intraclass correlation coefficient; 95% CI = 95% confidence interval; TE = typical error; ES = effect size; Index = reliability index resulting from absolute and relative reliability statistics. Note. Central statistics represent the mean (± s) of five consecutive hops recorded for two trials across Day_1, Day_2, Day_3, and Day_3Offset experimental bouts.

Abbreviations: CT = contact time; FT = flight time; HopFreq = hopping frequency; ICC = intraclass correlation coefficient; 95% CI = 95% confidence interval; TE = typical error; ES = effect size; Index = reliability index resulting from absolute and relative reliability statistics. Note. Central statistics represent the mean (± s) of five consecutive hops recorded for two trials across Day_1, Day_2, Day_3, and Day_3Offset experimental bouts. Friedman’s test revealed no significant change in kleg (χ2 (5) = 0.68–10.23; p > 0.05) across Day_1, Day_2 and Day_3 testing bouts at any HopFreq. Despite exhibiting little change between days, reliability indices showed kleg exhibited weak-to-moderate consistency (ICC = 0.71–0.89; ICCLower = 0.29–0.73; ES = 0.08–0.26) between inter-day bouts across all HopFreq (Table 2). Examination of kinematic and kinetic variables (Table 3) shows limits in kleg measurement agreement originated from limits in Fz max and ΔLegL measurement consistency. Limits in kleg measurement agreement, were accompanied by weak consistency in kknee and khip between Day_1, Day_2 and Day_3 across all HopFreq (ICC = 0.62–0.84; ICCLower = 0.02–0.61; ES = 0.10–0.70). Only kankle exhibited moderate-to-strong consistency at slower HopFreq (ICC = 0.91–0.94; ICCLower = 0.76–0.83; ES = 0.17–0.18). Examination of kinematic and kinetic variables (Table 3) shows that despite limits to kknee and khip at 1.5 Hz, participants exhibited weak-to-strong consistency for joint kinetic and kinematic variables. At 2.2 and 3.0 Hz, limits in kknee and khip resulted from weak-to-moderate agreement for joint kinetics and kinematics. Data show that strong consistency in kankle measures at 1.5 Hz was accompanied by strong consistency in Mankle max and Δϴankle. Limits in kankle measurement agreement at 2.2 and 3.0 Hz were accompanied by varied consistency in ankle kinematic and kinetic measures. Joint kinetics and kinematics showed no change (p > 0.05) between inter-day test bouts at any hopping frequency.
Table 2

Descriptive and reliability statistics (mean ± s) for variables of kleg and kjoint recorded between inter- and intra-day testing bouts during hopping within a SBS.

Inter-day Comparisons
Mean (± s)ICCICC 95% CITEESIndex
VariablesDay_1Day_2Day_3LowerUpper
1.5 Hz
 kleg (kN.m-1)4.85 (0.82)4.70 (1.04)5.00 (1.80)0.8870.7310.9680.570.08Moderate
 kankle (Nm.deg-1)2.27 (0.69)2.22 (0.69)2.45 (0.64)0.9360.8330.9850.320.18Strong
 kknee (Nm.deg-1)1.14 (1.28)1.65 (2.29)0.94 (0.72)0.7890.4850.9407.440.10Weak
 khip (Nm.deg-1)14.70 (14.18)11.61 (5.16)10.49 (5.17)0.8380.6110.95418.480.34Weak
2.2 Hz
 kleg (kN.m-1)7.69 (1.25)8.19 (1.63)8.22 (1.29)0.7700.4300.9400.90.26Weak
 kankle (Nm.deg-1)4.06 (1.57)3.41 (0.93)3.75 (1.08)0.9090.7620.9792.200.17Moderate
 kknee (Nm.deg-1)24.9 (31.56)15.21 (12.57)7.17 (6.22)0.7420.0150.9828.210.70Weak
 khip (Nm.deg-1)109.77 (154.56)100.68 (133.98)121.02 (171.15)0.6230.3760.79417.370.05Weak
3.0 Hz
 kleg (kN.m-1)11.5 (3.30)11.01 (2.30)12.79 (7.20)0.7130.2880.9255.110.20Weak
 kankle (Nm.deg-1)5.12 (1.81)4.53 (1.64)5.04 (1.96)0.8840.6950.9731.690.03Weak
 kknee (Nm.deg-1)28.47 (27.18)41.72 (74.19)61.05 (82.54)0.7470.5840.86113.930.35Weak
 khip (Nm.deg-1)47.84 (73.03)20.57 (23.85)34.73 (59.67)0.6250.3820.79517.300.17Weak
Intra-day Comparisons
Mean (± s)ICCICC 95% CITEESIndex
VariablesDay_3Day_3OffsetLowerUpper
1.5 Hz
 kleg (kN.m-1)5.00 (1.80)5.00 (1.33)0.8580.6990.9441.050.11Weak
 kankle (Nm.deg-1)2.45 (0.64)2.61 (0.86)0.8330.6350.9370.760.13Weak
 kknee (Nm.deg-1)0.94 (0.72)8.99 (8.98)0.3860.0000.8598.980.02Weak
 khip (Nm.deg-1)10.49 (5.17)17.93 (11.75)0.8640.6940.95110.850.18Weak
2.2 Hz
 kleg (kN.m-1)8.22 (1.29)11.76 (14.30)0.5940.0910.8541.680.35Weak
 kankle (Nm.deg-1)3.75 (1.08)5.39 (6.29)0.8470.6420.9481.130.25Weak
 kknee (Nm.deg-1)7.17 (6.22)12.70 (12.48)0.6830.0000.94111.600.15Weak
 khip (Nm.deg-1)121.02 (171.15)24.71 (19.08)0.8880.4170.99716.180.10Weak
3.0 Hz
 kleg (kN.m-1)12.79 (7.20)12.56 (5.25)0.8650.7050.9493.900.17Moderate
 kankle (Nm.deg-1)5.04 (1.96)6.70 (4.14)0.9150.8140.9682.260.14Strong
 kknee (Nm.deg-1)61.05 (82.54)6.76 (5.11)0.2870.0000.7477.950.50Weak
 khip (Nm.deg-1)34.73 (59.67)12.43 (11.61)0.8850.7200.96310.100.06Moderate

Abbreviations: kleg = leg-spring stiffness; kankle, kknee, khip = stiffness variables for ankle, knee, and hip joints, respectively; ICC = intraclass correlation coefficient; 95% CI = 95% confidence interval; TE = typical error; ES = effect size; Index = reliability index resulting from absolute and relative reliability statistics. Note. Central statistics represent the mean (± s) of 5 consecutive hops recorded for 2 trials across Day_1, Day_2, Day_3, and Day_3Offset experimental bouts.

Table 3

Descriptive (mean ± s) and reliability statistics for kinetic and kinematic variables recorded between inter-day testing bouts during hopping within a SBS.

Inter-day Comparisons
Mean (± s)ICCICC 95 % CITEESIndex
VariablesDay 1Day 2Day_3LowerUpper
1.5 Hz
 Fz max (N)435 (109)423 (93)446 (107)0.9760.9430.993230Strong
 Mankle max (Nm)53.27 (14.83)52.83 (14.38)54.72 (14.13)0.9360.8460.9816.110.07Strong
 Mknee max (Nm)5.05 (10.89)8.50 (7.76)6.04 (9.57)0.6650.1670.9058.590.07Weak
 Mhip max (Nm)75.35 (39.48)84.88 (37.26)94.19 (51.26)0.9530.8880.98614.690.29Strong
 Δ ϴankle (°)24.62 (5.67)25.06 (5.66)24.78 (5.47)0.9640.9080.9912.200.02Strong
 Δ ϴknee (°)15.09 (6.92)13.95 (6.46)15.05 (5.93)0.9370.8500.9821.900.00Strong
 Δ ϴhip (°)5.95 (3.20)5.47 (2.95)6.42 (3.05)0.9600.9000.9891.000.10Strong
 ΔLegL (m)0.05 (0.05)0.07 (0.04)0.08 (0.05)0.8890.7310.9680.010.41Moderate
2.2 Hz
 Fz max (N)439 (82)425 (77)456 (66)0.9130.7830.977210Moderate
 Mankle max (Nm)53.77 (10.33)50.53 (10.94)54.11 (10.58)0.8470.5890.9656.010.02Weak
 Mknee max (Nm)7.77 (5.04)8.68 (7.37)9.70 (8.68)0.7250.2990.9294.050.18Weak
 Mhip max (Nm)75.40 (29.76)67.25 (30.11)89.95 (90.95)0.8420.5850.96346.030.19Weak
 Δ ϴankle (°)14.63 (3.03)15.01 (3.03)15.08 (2.41)0.9430.8570.9851.400.11Strong
 Δ ϴknee (°)2.66 (1.25)3.02 (1.32)3.18 (1.30)0.6820.1940.9171.000.27Weak
 Δ ϴhip (°)1.93 (1.11)1.51 (0.88)1.84 (0.99)0.8270.5670.9550.700.06Weak
 ΔLegL (m)0.04 (0.03)0.04 (0.03)0.04 (0.03)0.7210.3310.9260.010.15Weak
3.0 Hz
 Fz max (N)446 (54)445 (63)458 (47)0.9670.9170.991160Strong
 Mankle max (Nm)53.39 (9.61)54.40 (11.15)60.71 (19.71)0.9220.8070.9804.700.36Strong
 Mknee max (Nm)12.88 (11.33)8.91 (11.13)8.47 (12.46)0.8730.6880.9667.570.25Weak
 Mhip max (Nm)49.92 (34.54)51.79 (26.49)71.57 (47.38)0.8830.7120.96915.890.40Moderate
 Δ ϴankle (°)10.93 (2.61)12.49 (3.38)11.87 (3.80)0.9010.7550.9742.000.19Moderate
 Δ ϴknee (°)2.85 (1.04)3.04 (1.82)2.42 (2.11)0.5190.0000.8761.300.18Weak
 Δ ϴhip (°)4.27 (1.81)4.27 (2.03)4.03 (1.58)0.7280.3080.9301.700.09Weak
 ΔLegL (m)0.02 (0.02)0.03 (0.02)0.03 (0.02)0.7850.4510.9450.010.34Weak

Abbreviations: ICC = intraclass correlation coefficient; 95% CI = 95% confidence interval; TE = typical error; ES = effect size; Index = reliability index resulting from absolute and relative reliability statistics; Fz max = maximum ground reaction force; Mankle max, Mknee max, and Mhip max = maximum resultant moments recorded for ankle, knee, and hip joints, respectively; Δϴankle, Δϴknee, and Δϴhip = relative angular displacement at ankle, knee, and hip joints, respectively; ΔLegL = change in leg length. Note. Central statistics represent the mean (± s) of 5 consecutive hops recorded for 2 trials across Day_1, Day_2, and Day_3 experimental bouts.

Abbreviations: kleg = leg-spring stiffness; kankle, kknee, khip = stiffness variables for ankle, knee, and hip joints, respectively; ICC = intraclass correlation coefficient; 95% CI = 95% confidence interval; TE = typical error; ES = effect size; Index = reliability index resulting from absolute and relative reliability statistics. Note. Central statistics represent the mean (± s) of 5 consecutive hops recorded for 2 trials across Day_1, Day_2, Day_3, and Day_3Offset experimental bouts. Abbreviations: ICC = intraclass correlation coefficient; 95% CI = 95% confidence interval; TE = typical error; ES = effect size; Index = reliability index resulting from absolute and relative reliability statistics; Fz max = maximum ground reaction force; Mankle max, Mknee max, and Mhip max = maximum resultant moments recorded for ankle, knee, and hip joints, respectively; Δϴankle, Δϴknee, and Δϴhip = relative angular displacement at ankle, knee, and hip joints, respectively; ΔLegL = change in leg length. Note. Central statistics represent the mean (± s) of 5 consecutive hops recorded for 2 trials across Day_1, Day_2, and Day_3 experimental bouts. Examination of intra-day testing comparisons (Table 2) showed no change in kleg between Day_3 and Day_3Offset (χ2 (3) = 0.60–3.19; p > 0.05). Despite this, kleg measures exhibited weak consistency at 1.5 and 2.2 Hz HopFreq (ICC = 0.59–0.86; ICCLower = 0.09–0.70; ES = 0.11–0.35) and moderate consistency at 3.0 Hz (ICC = 0.87; ICCLower = 0.71; ES = 0.17). Limits in kleg reliability originated from strong and weak consistency in Fz max and ΔLegL respectively at all HopFreq. Repeated measure ANOVA results showed no change in kjoint variables between Day_3 and Day_3Offset (F (1.1, 22.6) = 0.17–1.07; p > 0.05). Despite this, kknee and khip exhibited weak-to-moderate consistency between Day_3 and Day_3Offset (ICC = 0.29–0.89; ICCLower = 0.00–0.72; ES = 0.02–0.50). In contrast, kankle exhibited strong consistency at 3.0 Hz but weak consistency at other hopping frequencies. Examination of kinematic and kinetic data (Table 4) showed limits in kjoint reliability originated from largely weak-to-moderate consistency in joint kinematic and kinetic inputs between Day_3 and Day_3Offset. Limits in consistency in kinematic and kinetic inputs occurred despite no change in these data between Day_3 and Day_3Offset testing bouts (χ2 (3) = 0.98–3.86; p > 0.05).
Table 4

Descriptive (mean ± s) and reliability statistics for kinetic and kinematic variables recorded between intra-day testing bouts during hopping within a SBS.

Intra-day Comparisons
Mean (± s)ICCICC 95% CITEESIndex
VariablesDay_3Day_3OffsetLowerUpper
1.5 Hz
 Fz max (N)446 (107)467 (125)0.9700.9360.988190Strong
 Mankle max (Nm)54.72 (14.13)57.56 (18.48)0.9020.7900.9629.190.09Moderate
 Mknee max (Nm)6.04 (9.57)8.37 (14.59)0.6510.1100.89610.830.20Weak
 Mhip max (Nm)94.19 (51.26)84.64 (53.07)0.8520.6790.94419.040.05Weak
 Δ ϴankle (°)24.78 (5.47)23.1 (5.0)0.9070.8030.9642.800.11Strong
 Δ ϴknee (°)15.05 (5.93)3.1 (6.8)0.8950.7740.9594.200.02Moderate
 Δ ϴhip (°)6.42 (3.05)5.2 (3.5)0.9530.8990.9810.900.06Strong
 ΔLegL (m)0.08 (0.05)0.09 (0.02)0.8570.6960.9440.010.13Weak
2.2 Hz
 Fz max (N)456 (66)483 (83)0.9910.9800.997140Strong
 Mankle max (Nm)54.11 (10.58)71.58 (51.69)0.7160.3720.89735.270.28Weak
 Mknee max (Nm)9.70 (8.68)10.93 (9.36)0.7520.4140.9197.360.10Weak
 Mhip max (Nm)89.95 (90.95)86.71 (71.85)0.8940.7570.96438.910.04Moderate
 Δ ϴankle (°)15.08 (2.41)14.7 (5.0)0.8480.6530.9461.900.15Weak
 Δ ϴknee (°)3.18 (1.30)-2.3 (2.5)0.8850.7440.9591.400.23Moderate
 Δ ϴhip (°)1.84 (0.99)-1.9 (1.9)0.8330.6210.9400.800.23Weak
 ΔLegL (m)0.04 (0.03)0.06 (0.01)0.6430.1710.8780.010.23Weak
3.0 Hz
 Fz max (N)458 (47)461 (54)0.9820.9590.993130Strong
 Mankle max (Nm)60.71 (19.71)62.57 (16.98)0.6130.1870.8516.290.37Weak
 Mknee max (Nm)8.47 (12.46)10.59 (15.30)0.8040.5190.9379.300.22Weak
 Mhip max (Nm)71.57 (47.38)65.13 (49.60)0.8440.6510.94420.200.02Weak
 Δ ϴankle (°)11.87 (3.80)9.50 (8.10)0.9750.9460.9915.300.19Strong
 Δ ϴknee (°)2.42 (2.11)-3.60 (2.50)0.5340.0000.8281.100.25Weak
 Δ ϴhip (°)4.03 (1.58)-5.10 (2.50)0.7990.5630.9242.000.34Weak
 ΔLegL (m)0.03 (0.02)0.04 (0.01)0.7490.4350.9130.010.01Weak

Abbreviations: ICC = intraclass correlation coefficient; 95% CI = 95% confidence interval; TE = typical error; ES = effect size; Index = reliability index resulting from absolute and relative reliability statistics; Fz max = maximum ground reaction force; Mankle max, Mknee max, and Mhip max = maximum resultant moments recorded for ankle, knee, and hip joints, respectively; Δϴankle, Δϴknee, and Δϴhip = relative angular displacement at ankle, knee, and hip joints, respectively; ΔLegL = change in leg length. Note. Central statistics represent the mean (± s) of 5 consecutive hops recorded for 2 trials across Day_3 and Day_3Offset experimental bouts.

Abbreviations: ICC = intraclass correlation coefficient; 95% CI = 95% confidence interval; TE = typical error; ES = effect size; Index = reliability index resulting from absolute and relative reliability statistics; Fz max = maximum ground reaction force; Mankle max, Mknee max, and Mhip max = maximum resultant moments recorded for ankle, knee, and hip joints, respectively; Δϴankle, Δϴknee, and Δϴhip = relative angular displacement at ankle, knee, and hip joints, respectively; ΔLegL = change in leg length. Note. Central statistics represent the mean (± s) of 5 consecutive hops recorded for 2 trials across Day_3 and Day_3Offset experimental bouts.

Discussion

SBS are used to examine SSC function under controlled conditions. Sled design regulates eccentric loading and limits extraneous movement to improve landing and measurement consistency. During overground hopping and running, kleg has demonstrated good reliability [22,23]. In contrast, kjoint measures have demonstrated limited consistency. The reliability of kleg and kjoint while hopping within an SBS had not been examined. This study provides a comprehensive analysis of the inter- and intra-day reliability of kleg and kjoint achieved during hopping within an SBS. Similar to the findings of Hobara and colleagues [21] kleg and kjoint increased with increases in HopFreq in the present study. Values of 13.9–28.9 kN.m-1 have been reported for kleg during natural hopping conditions on different surfaces and at different frequencies [22,23,30,45,46]. In addition, values of 6.9–12.0 Nm.deg-1 have been reported for kankle during natural hopping [45]. In the present study, stiffness values are lower than reported during natural hopping [22,23]. This can be explained by the orientation of the frame of the SBS (i.e. 30° to the horizontal) which reduces (half) the effect of gravitational acceleration [12,19]. Therefore, lower ground reaction forces (i.e. Fz max) are expected in the present study relative to published reports on overground hopping. This is supported by the work of Harrison et al. [25] and Flanagan and Harrison [19] who reported lower values for kleg during DJ and RBJ tasks (3.4–8.5 kN.m-1) performed within the current SBS, relative to natural conditions. The stiffness data recorded during the present study are in line with previous data reported for SSC tasks performed within an inclined-SBS. Hobara et al. [21] showed increases in kleg with increases in HopFreq. Thus, regulation of HopFreq between testing bouts was important to reliability analysis. In the current study HopFreq displayed weak-to-moderate consistency across all trials despite CT and FT variables showing strong agreement at all HopFreq between Day_3 and Day_3Offset. Inter-day comparisons showed strong consistency for CT throughout. In contrast, FT exhibited strong agreement at 1.5 and 3.0 Hz but moderate consistency at 2.2 Hz. Hopkins and colleagues [41] suggested low ICC’s occur in situations where between participant variation is low for a given variable. In the present study, HopFreq was regulated to within 5% of the target frequency. Thus, low levels of variability may have produced spurious reliability indices in HopFreq and in FT measures during hopping at 2.2 Hz. The low TE (0.01–0.02) and ES (≤ 0.31) for CT, FT and HopFreq support this. Thus, HopFreq was controlled adequately throughout. Despite regulation of HopFreq in the present study, kleg exhibited moderate reliability at 1.5 Hz and weak reliability at 2.2 and 3.0 Hz (ICC = 0.59–0.89) between inter-day test bouts. These reliability indexes were accompanied by strong consistency for kankle at 1.5 Hz only. Remaining kjoint variables demonstrated weak-to-moderate agreement between Day_1, Day_2 and Day_3 testing bouts. Between Day_3 and Day_3Offset, kleg exhibited moderate reliability at 3.0 Hz but weak consistency at the other frequencies. The moderate index for kleg at 3.0 Hz was accompanied by strong consistency for kankle. Variables of kknee and khip however, exhibited weak-to-moderate consistency throughout. Examination of kinematic and kinetic inputs (Tables 3 and 4) showed that limits in kleg reliability occurred due to limits in ΔLegL reliability, while Fz max exhibited moderate-to-strong consistency. The present data also showed that limits in kjoint measurement agreement resulted from inconsistencies in Mjoint max and Δϴjoint at the highest hopping frequencies (2.2 and 3.0 Hz). While the present study did not include a control condition, previous work in our lab examined the reliability of kleg and kjoint measures in overground hopping [22]. This study employed the same methodology and used physically active participants consistent with the current work. Our work showed strong agreement (ICC = 0.95–0.98) for kleg and kankle measures at different hopping frequencies [22]. In contrast, kknee and khip exhibited weak-to-moderate agreement. Given our previous findings, that many stiffness variables showed weak-to-moderate agreement in the present study is surprising. Particularly since the primary function of the current inclined-SBS is to limit extraneous upper body movement to enhance landing and measurement consistency during SSC tasks [8,19]. It is understood that in biological measurement, observed scores are composed of a true score and additional error [42]. Weir [42] suggests that errors in measurement data result from instrumentation errors associated with equipment used, in addition to participant / tester error, modelling error and biological variability. In the context of the current work, instrumentation errors arise from equipment (force plate and video) use and protocol adherence between testing bouts. It is important to note that participants were instructed refrain from physical activity prior to data collection. Furthermore, force plate and video equipment were calibrated as per the manufacturer’s guidelines prior to each data collection period. In addition, equipment set-up and protocols used were consistent with published works showing strong reliability for kleg and kankle during overground hopping [22]. Consequently, deteriorations in measurement consistency relative to published reports are not due to differences in testing protocols between studies. Of additional concern to the reliability of kleg and kjoint scores is error derived from the use of mathematical models. Whittlesey and Hammill [47] noted that models are sensitive to the number of model components. Thus, small errors present early in the modelling process will propagate by the end of the simulation. This suggests that modelling errors will increase as calculations progress from distal to proximal joints. As kjoint is the ratio of changes in Mjoint and ϴjoint, it is clear that errors in Mjoint (and kknee and khip) measures will increase as inverse dynamics analysis progresses from distal to proximal joints. It is important to consider that while these errors will influence kjoint consistency, they are unlikely to influence kleg in the present work. In addition, as modelling procedures employed in the current work are consistent with previous works [22], it is unlikely that differences in measurement consistency between the current and previous works result from modelling errors. Considering biological variability, our previous work on overground hopping noted the existence of kleg as an attractor state [22] where participants are drawn to the manipulation of leg compression (seen by variable kjoint or ΔLegL) to maintain a consistent kleg under variable landing conditions [9,45]. These works also showed that stiffness variables were accompanied by mostly strong consistency for Fz max and ΔLegL variables. In the present study, it must be considered that while the reliability of Fz max was strong, the reliability of ΔLegL was weak-to-moderate across all testing bouts. As a result, the kleg exhibited weak-to-moderate consistency throughout. It is therefore difficult to establish a consistent outcome variable (i.e. attractor state) that participants are trying to regulate. Furthermore, considering limits in the reliability of kinematic and kinetic variables measured, and the limited pattern to the nature of this reliability, we feel that our data does not support the notion that limits in reliability are due to kinematic variability to achieve consistent outcomes. It is important to consider the novelty of the hopping task and its impact on the present data. Our previous work showed that familiarizing participants with testing procedures prior to data collection enhanced measurement reliability relative to earlier reports [23]. In the present study however, participants completed a familiarization session prior to data collection. Thus, acquainting participants with procedures did not benefit the consistency of hopping dynamics within the current SBS. One reason for this is likely the design of the current SBS. The design of the current SBS requires participants to adopt a flexed torso position while secured to it. This novel hopping position would alter the functional length of lower limb musculature compared to upright hopping, which will have impacted participants’ ability to achieve consistent hopping dynamics. In addition, the mass of the chair of the current SBS was 19.6 kg. The added mass may have made it difficult for participants to achieve consistency in their hopping patterns. This is partly supported by the work of Kramer et al. [48]. The authors demonstrated that participants achieved almost natural reactive jumps following this four-week period (i.e. 12 sessions). While the instructions regarding landing dynamics differed from the current study, the design of the lightweight sled (5 kg) allowed participants to adopt natural movement patterns [27,48]. Although the authors did not report reliability indices for variables measured, the changes seen (38% increase) following four weeks of training (i.e. familiarizing) suggest the performance of SSC tasks within an SBS to be a novel task requiring extensive participant familiarization. The practicalities of including multiple familiarization sessions prior to data collection must also be considered. Considering the lack of reliability evident in kinematics, kinetics and stiffness variables measured, it is appropriate to accept the null hypothesis. Limiting extraneous upper body movement by using an SBS during single-leg hopping did not improve the reliability of kleg and kjoint measures relative to previous reports on overground hopping. In fact, use of the current SBS reduced consistency of stiffness measures relative to previous reports on natural conditions.

Conclusions

To summarize, the present data showed weak-to-moderate reliability for all stiffness measures during hopping using the current SBS. This was due largely to inconsistencies in leg compression (ΔLegL). Thus, reducing extraneous upper body movement using the current SBS did not encourage consistent stiffness regulation. In fact, hopping within the current inclined-SBS had adverse effects on measurement consistency relative to published reports on overground hopping. Limits in the consistency of stiffness measures may be due to constraints imposed by restricting upper body movement, which introduced novelty to the single-leg hopping task. A single familiarization session was therefore inadequate to achieve consistent landing mechanics. The influence of sled design on the current findings must also be considered, with chair mass and orientation likely making it difficult for participants to achieve consistent hopping patterns. Researchers should consider these findings and endeavour to construct a light-weight system with a chair orientation that replicates the functional length of the muscle-tendon units driving the SSC task being analysed.
  37 in total

1.  Measures of reliability in sports medicine and science.

Authors:  W G Hopkins
Journal:  Sports Med       Date:  2000-07       Impact factor: 11.136

2.  Force-velocity relationship and stretch-shortening cycle function in sprint and endurance athletes.

Authors:  Andrew J Harrison; Sean P Keane; John Coglan
Journal:  J Strength Cond Res       Date:  2004-08       Impact factor: 3.775

3.  The interday reliability of leg and ankle musculotendinous stiffness measures.

Authors:  Ken A McLachlan; Aron J Murphy; Mark L Watsford; Sven Rees
Journal:  J Appl Biomech       Date:  2006-11       Impact factor: 1.833

4.  Muscle dynamics differences between legs in healthy adults.

Authors:  Eamonn P Flanagan; Andrew J Harrison
Journal:  J Strength Cond Res       Date:  2007-02       Impact factor: 3.775

5.  Leg stiffness adjustment for a range of hopping frequencies in humans.

Authors:  Hiroaki Hobara; Koh Inoue; Tetsuro Muraoka; Kohei Omuro; Masanori Sakamoto; Kazuyuki Kanosue
Journal:  J Biomech       Date:  2009-10-30       Impact factor: 2.712

6.  Neuromuscular characteristics and muscle power as determinants of 5-km running performance.

Authors:  L M Paavolainen; A T Nummela; H K Rusko
Journal:  Med Sci Sports Exerc       Date:  1999-01       Impact factor: 5.411

7.  Fatigue, vertical leg stiffness, and stiffness control strategies in males and females.

Authors:  Darin A Padua; Brent L Arnold; David H Perrin; Bruce M Gansneder; Christopher R Carcia; Kevin P Granata
Journal:  J Athl Train       Date:  2006 Jul-Sep       Impact factor: 2.860

8.  EMG activity of the leg extensor muscles with special reference to mechanical efficiency in concentric and eccentric exercise.

Authors:  P V Komi; M Kaneko; O Aura
Journal:  Int J Sports Med       Date:  1987-03       Impact factor: 3.118

9.  Leg stiffness primarily depends on ankle stiffness during human hopping.

Authors:  C T Farley; D C Morgenroth
Journal:  J Biomech       Date:  1999-03       Impact factor: 2.712

10.  Lower extremity joint stiffness in runners with low back pain.

Authors:  Joseph Hamill; Michael Moses; Joseph Seay
Journal:  Res Sports Med       Date:  2009       Impact factor: 4.674

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.