Epicutaneo-caval catheters in neonates: New insights and new suggestions from the recent literature.

Giovanni Barone1, Mauro Pittiruti2.   

Abstract

Epicutaneo-caval catheters have been widely used in neonatal intensive care units since Shaw has described them in 1973. These central venous access devices are usually placed at bedside and they have the purpose of delivering parenteral nutrition and/or drugs that are not compatible with the peripheral route. Even though in the last decade there was a fast advancement in the world of vascular access devices, such changes have only marginally affected the field of neonatal venous access. The aim of this editorial is to give 10 recommendations that correspond to 10 novelties in the field of epicutaneo-caval catheter: some are already evidence-based and should be introduced in our daily practice now, while others are particularly interesting and deserve further clinical studies.

Entities:  

Keywords:  Neonatal intensive care unit; central venous catheter; centrally inserted central catheter; epicutaneo-caval catheter; femorally inserted central catheter; newborn; peripherally inserted central catheters

Year:  2019        PMID: 31804149     DOI: 10.1177/1129729819891546

Source DB:  PubMed          Journal:  J Vasc Access        ISSN: 1129-7298            Impact factor:   2.283


  4 in total

1.  Effect of implementing an Epicutaneo-Caval Catheter team in Neonatal Intensive Care Unit.

Authors:  Mohammad A A Bayoumi; Matheus F P Van Rens; Prem Chandra; Airene L V Francia; Sunitha D'Souza; Majee George; Saad Shahbal; Einas E Elmalik; Irian J E Cabanillas
Journal:  J Vasc Access       Date:  2020-06-30       Impact factor: 2.283

2.  Peripherally inserted central catheters versus non-tunnelled ultrasound-guided central venous catheters in newborns: a retrospective observational study.

Authors:  Mohammad A A Bayoumi; Roland van Rens; Prem Chandra; Deena Shaltout; Ashraf Gad; Einas E Elmalik; Samer Hammoudeh
Journal:  BMJ Open       Date:  2022-04-06       Impact factor: 2.692

3.  Retrospective Study of the Application Value Analysis of Ultrasound-Guided Technology in Peripheral Deep Venous Catheterization of Neonates.

Authors:  Tingting Yin; Yuan Huo; Yang Zhao; Weiyang Li; Hongxia Gao
Journal:  Dis Markers       Date:  2022-07-23       Impact factor: 3.464

4.  A Survey of the Practice Status Quo of Ultrasound-Guided ECC Tip Location for Neonatal Patients in 31 Provinces of China.

Authors:  Xuexiu Liu; Xiaojun Tao; Ye Xu; Xianhong Zhang; Liping Wu
Journal:  Front Pediatr       Date:  2022-07-14       Impact factor: 3.569