| Literature DB >> 31802838 |
Luísa Malheiro1, João Coelho1, Miguel Mesquita Neves1,2, Miguel Gomes1,2, Luís Oliveira1,2.
Abstract
PURPOSE: To report outcomes of phakic intraocular lens (IOL) implantation after deep anterior lamellar keratoplasty (DALK) to correct high ametropia.Entities:
Keywords: deep anterior lamellar keratoplasty; endothelial cell density; phakic intraocular lens; refractive outcomes; visual outcomes
Year: 2019 PMID: 31802838 PMCID: PMC6802541 DOI: 10.2147/OPTH.S202054
Source DB: PubMed Journal: Clin Ophthalmol ISSN: 1177-5467
Preoperative Parameters Of The Study Population
| Patient | Age At The Time Of IOL Implantation (Years) | Time Between DALK And IOL Implantation (Months) | Preoperative Subjective Refraction (D) | Preoperative ECD (Cells/mm | Preoperative ACD (mm) |
|---|---|---|---|---|---|
| 1 | 26 | 314 | −5.0–4.5×170° | 2674 | 3.59 |
| 2 | 27 | 25.9 | −13.0–2.0×150° | 2404 | 3.75 |
| 3 | 37 | 34.6 | +2.5–6.5×10° | 1515 | 3.20 |
| 4 | 34 | 42.0 | −6.0×30° | 2320 | 3.25 |
| 5 | 36 | 63.3 | −7.5–10.0×145° | 2915 | 3.70 |
| 6 | 42 | 39.3 | −8.0–10.0×90° | 1835 | 4.11 |
| 7 | 24 | 30.6 | −4.0–5.0×55° | 1800 | 3.83 |
| 8 | 18 | 30.2 | −7.0–7.0×145° | 2703 | 3.88 |
| 9 | 35 | 29.6 | −1.0–8.5×50° | 2250 | 3.31 |
| 10 | 23 | 35.9 | −5.5–11.0×10° | 2994 | 3.70 |
| 11 | 26 | 29.4 | +3.0–11.0×105° | 2088 | 3.74 |
Figure 1Postoperative slit-lamp photograph 1 year after toric Artisan phakic intraocular lens implantation in eye with previous DALK.
Mean Preoperative And 1, 3 And 5 Years Postoperative Results Of Toric Phakic IOL Implantation After DALK: Comparative Analysis
| Outcomes | UDVA | CDVA | Refractive Cylinder | ECD (Cells/mm | ||||
|---|---|---|---|---|---|---|---|---|
| Mean±SD | p-Value | Mean±SD | p-Value | Mean±SD | p-Value | Mean±SD | p-Value | |
| Preoperative vs 1 year postoperative (n=11) | 1.27±0.90 vs 0.16±0.15 | 0.16±0.14 vs 0.07±0.09 | −7.41±3.61 vs −1.00±0.95 | 2318±457 vs 2108±547 | ||||
| Preoperative vs 3 year postoperative (n=11) | 1.27±0.90 vs 0.22±0.17 | 0.16±0.14 vs 0.08±0.10 | −7.41±3.61 vs −1.63±0.90 | 2318±457 vs 1961±574 | ||||
| Preoperative vs 5 year postoperative (n=5) | 1.30±0.0 vs 0.12±0.11 | 0.14±0.09 vs 0.02±0.04 | −6.75±2.04 vs −0.85±0.49 | 2105±438 vs 1768±548 | 0.137 | |||
| 1 year postoperative vs 3 years postoperative (n=11) | 0.16±0.15 vs 0.22±0.17 | 0.364 | 0.07±0.09 vs 0.08±0.10 | 0.341 | −1.00±0.95 vs −1.63±0.90 | 2108±547 vs 1961±574 | 0.523 | |
| 1 year postoperative vs 5 years postoperative (n=5) | 0.16±0.21 vs 0.12±0.11 | 0.757 | 0.02±0.04 vs 0.03±0.07 | 0.945 | −0.37±0.40 vs −0.85±0.49 | 0.102 | 2018±180 vs 1768±548 | 0.090 |
| 3 years postoperative vs 5 years postoperative (n=5) | 0.14±0.09 vs 0.12±0.11 | 0.317 | 0.04±0.05 vs 0.03±0.07 | 0.317 | −0.83±0.44 vs −0.85±0.49 | 0.921 | 1840±591 vs 1768±548 | 0.255 |
Note: Significant values are shown in bold.
Figure 2Cumulative uncorrected distance visual acuity 1 year after surgery (n=11).
Figure 3Change in corrected distance visual acuity 1 year after surgery (n=11).
Figure 4Preoperative and 1 year postoperative refractive cylinder (n=11) in diopters.
Figure 5Spherical equivalent refractive accuracy 1 year after surgery (n=11).
Figure 6Stability of spherical equivalent during follow-up.
Visual And Refractive Outcomes At 3 Years Follow-Up
| Patient | Pre-UDVA (logMAR) | Pre-BDVA (logMAR) | Preoperative Refraction (D) | Type Of Toric Phakic IOL Implanted | 3 Years Post-UDVA (logMAR) | 3 Years Post-BDVA (logMAR) | 3 Years Postoperative Refraction (D) |
|---|---|---|---|---|---|---|---|
| 1 | 1.30 | 0.20 | −5.0–4.5×170° | Artiflex | 0.30 | 0.10 | −0.75–2.50×100° |
| 2 | 1.30 | 0.00 | −13.0–2.0×150° | Artisan | 0.00 | 0.00 | −0.50×170° |
| 3 | 1.30 | 0.00 | +2.5–6.5×10° | Artisan | 0.00 | 0.00 | −0.50×20° |
| 4 | 1.30 | 0.10 | −6.0×30° | Artisan | 0.20 | 0.10 | −1.00–2.00×110° |
| 5 | 1.30 | 0.20 | −7.5–10.0×145° | Artisan | 0.20 | 0.10 | −2.00–2.00×55° |
| 6 | 1.30 | 0.50 | −8.0–10.0×90° | Artisan | 0.50 | 0.30 | −1.00–1.00×70° |
| 7 | 1.30 | 0.20 | −4.0–5.0×55° | Artiflex | 0.20 | 0.00 | −1.50×35° |
| 8 | 1.30 | 0.20 | −7.0–7.0×145° | Artiflex | 0.20 | 0.10 | −1.25×110° |
| 9 | 1.30 | 0.20 | −1.0–8.5×50° | Artisan | 0.20 | 0.00 | −1.00–0.50×40° |
| 10 | 1.30 | 0.00 | −5.5–11.0×10° | Artisan | 0.50 | 0.00 | −3.00–0.75×0° |
| 11 | 1.00 | 0.20 | +3.0–11.0×105° | Artisan | 0.20 | 0.10 | +1.00–2.50×100° |
Differences In Corneal Thickness, Anterior Chamber Depth And Topographic Astigmatism During Follow-Up
| Preoperative | 1 Year (n=11) | 3 Years (n=11) | 5 Years (n=5) | p-Value 3 YearsFollow-Up (n=11) | p-Value 5 YearsFollow-Up (n=5) | |
|---|---|---|---|---|---|---|
| Corneal thickness (um) | 518±56.1 | 515±48.2 | 507±52.8 | 536±22.3 | 0.661 | 0.847 |
| ACD (mm) | 3.62±0.33 | 3.53±0.35 | 3.48±0.26 | 3.48±0.41 | 0.154 | 0.528 |
| Topographic astigmatism (D) | 6.82±2.70 | 5.88±3.49 | 5.49±3.95 | 5.24±2.10 | 0.387 | 0.089 |
Summary Of Authors And Their Study’ Results For ECD Loss After Keratoplasty And After Phakic IOLs Implantation In Eyes With And Without Keratoplasty
| Author, Year | Technique | Sample Size(n= Eyes) | Country | ECD Loss |
|---|---|---|---|---|
| Tiveron et al, | Artisan and Artiflex IOLs after DALK | 24 | Spain | 1 year: 6.10% |
| Tahzib et al, | Artisan IOL after PK | 34 | The Netherlands | 1 year: 21.2% (n=34) |
| Cheng, | PK vs DALK | 56 | The Netherlands | 1 year: 27.7% PK vs 12.9% DALK |
| Pop, | Artisan IOL without keratoplasty | 765 | Canada | 1 year: 0.87% |
| Hashemi, | Artisan IOL without keratoplasty | 53 | Iran | 1 year: 3.04% |
| Silva, | Artisan IOL without keratoplasty | 26 | USA | 5 years: 14.0% |
| Guerin et al, | Artiflex IOL without keratoplasty | 28 | Ireland | 1 year: 6.17% |
| Jonker, | Artiflex IOL without keratoplasty | 188 | The Netherlands | 5 years: 10.2% |
| Our Center, 2018 | DALK | 47 | Portugal | 1 year: 5.3% |
| Current study, 2019 | Toric phakic IOLs after DALK | 11 | Portugal | 1 year: 8.7% (n=11) |