Literature DB >> 31802574

Impact of Different Scan Bodies and Scan Strategies on the Accuracy of Digital Implant Impressions Assessed with an Intraoral Scanner: An In Vitro Study.

Constantin Motel1, Elena Kirchner1, Werner Adler2, Manfred Wichmann1, Ragai Edward Matta1.   

Abstract

PURPOSE: Sufficient data are not currently available on how the various geometries of scan bodies and different scan strategies affect the quality of digital impressions of implants. The purpose of this study was to present new data on these two topics and give clinicians a basis for decision making.
MATERIALS AND METHODS: A titanium master model containing three Nobelreplace Select™ implants (Nobelbiocare Services AG, Zurich, Switzerland) was digitized using an ATOS industrial noncontact scanner. Digitization was repeated three times with different types of scan bodies integrated into the implants: ELOS A/S, nt-trading GmbH, and TEAMZIEREIS GmbH. These three scans served as virtual master models. The titanium master model was then scanned with the TRIOS3© digital intraoral scanner (ELOS A/S, Copenhagen, Denmark), which was used for two different scanning strategies. Strategy A was a one-step procedure that included both the titanium master model and the integrated scan bodies. Strategy B comprised two steps. First, a digital overlay was performed with a scan of the titanium master model without integrated scan bodies. A second scan was performed with the titanium master model and integrated scan bodies. By repeating both strategies 10 times for each type of scan body, 60 scans were generated and the corresponding standard tessellation language data sets overlaid with the corresponding virtual master model. Deviations in the resulting superimpositions were calculated and evaluated separately in the individual axes (x, y, z) and in three-dimensional space (Euclidean distance). Statistical evaluation was performed using the R-project software. Level of significance was determined at p ≤ 0.05.
RESULTS: With regard to the geometry of the scan bodies, strategy A significantly influenced the accuracy of the digital implant impression in regards to Euclidean distance (p = 0.003). No significant difference was found for strategy B in this context. Comparing the two scan strategies revealed that strategy A achieved significantly higher accuracy overall (p = 0.031).
CONCLUSION: The quality of digital intraoral impressions seems to be influenced by both the geometry of the scan body and the scan strategy. For clinical practice, the one-step scan strategy seems beneficial. Furthermore, the scan bodies of ELOS A/S showed a potential clinical advantage.
© 2019 The Authors American College of Prosthodontists.

Entities:  

Keywords:  Digital impressions; intraoral scan; precision; scan abutments; scanning procedure

Year:  2019        PMID: 31802574     DOI: 10.1111/jopr.13131

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  9 in total

1.  Effect of full arch two scanning techniques on the accuracy of overdenture conventional and CAD/CAM Co-Cr bars.

Authors:  Ali Alenezi; Mohammed Yehya; Mohamed Alkhodary
Journal:  Saudi Dent J       Date:  2022-08-28

2.  Trueness of ten intraoral scanners in determining the positions of simulated implant scan bodies.

Authors:  Ryan Jin Young Kim; Goran I Benic; Ji-Man Park
Journal:  Sci Rep       Date:  2021-01-28       Impact factor: 4.379

Review 3.  The direct digital workflow in fixed implant prosthodontics: a narrative review.

Authors:  George Michelinakis; Dimitrios Apostolakis; Phophi Kamposiora; George Papavasiliou; Mutlu Özcan
Journal:  BMC Oral Health       Date:  2021-01-21       Impact factor: 2.757

Review 4.  The Modern and Digital Transformation of Oral Health Care: A Mini Review.

Authors:  Muhammad Syafiq Alauddin; Ahmad Syukran Baharuddin; Mohd Ifwat Mohd Ghazali
Journal:  Healthcare (Basel)       Date:  2021-01-25

Review 5.  Digital Impressions in Implant Dentistry: A Literature Review.

Authors:  Simone Marques; Paulo Ribeiro; Carlos Falcão; Bernardo Ferreira Lemos; Blanca Ríos-Carrasco; José Vicente Ríos-Santos; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2021-01-24       Impact factor: 3.390

6.  Trueness of digital implant impressions based on implant angulation and scan body materials.

Authors:  Jae-Hyun Lee; Jae-Hwi Bae; Su Young Lee
Journal:  Sci Rep       Date:  2021-11-08       Impact factor: 4.379

7.  Efficiency of occlusal and interproximal adjustments in CAD-CAM manufactured single implant crowns - cast-free vs 3D printed cast-based.

Authors:  Tobias Graf; Jan-Frederik Güth; Christian Diegritz; Anja Liebermann; Josef Schweiger; Oliver Schubert
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

8.  The Effect of Scanning Strategy on Intraoral Scanner's Accuracy.

Authors:  Nikolaos A Gavounelis; Chrysoula-Maria C Gogola; Demetrios J Halazonetis
Journal:  Dent J (Basel)       Date:  2022-07-04

9.  Bias Evaluation of the Accuracy of Two Extraoral Scanners and an Intraoral Scanner Based on ADA Standards.

Authors:  Naiyu Cui; Jiayin Wang; Xingyu Hou; Shixun Sun; Qixuan Huang; Ho-Kyung Lim; HongXin Cai; Qi Jia; Eui-Seok Lee; Heng Bo Jiang
Journal:  Scanning       Date:  2021-06-10       Impact factor: 1.932

  9 in total