Literature DB >> 31800406

Evaluation of autologous retransfusion from a closed suction drainage system for patient blood management in elective total hip and knee replacement: A two cohort study.

Sebastian Mayer-Rollnik1, Christoph Harms, Luca Bernasconi, Angelika Hammerer, Eric Reiss, Thierry Girard, Daniel Bolliger.   

Abstract

BACKGROUND: Postoperative autologous retransfusion of drainage blood might reduce the transfusion of red blood cell concentrates after major orthopaedic surgery.
OBJECTIVES: Our primary objective was to evaluate the effectiveness of a blood collection and retransfusion system. Secondary objectives included safety issues and the quality of the drainage blood collected.
DESIGN: Combined retrospective and prospective cohort study.
SETTING: Swiss regional hospital, from 1 January to 31 December 2015 (retrospective cohort) and 1 January to 31 August 2018 (prospective cohort). PATIENTS: The retrospective and prospective cohort included 216 and 46 patients, respectively, who underwent elective hip or knee replacement.
INTERVENTIONS: Use of a postoperative blood collection and retransfusion system. MAIN OUTCOME MEASURES: The primary outcome was the postoperative haemoglobin in patients with and without autotransfusion. Secondary outcomes were percentage of patients with transfusion of allogeneic blood products and with adverse events with and without autotransfusion. Tertiary outcomes were laboratory levels of specific inflammation and coagulation parameters in collected drain blood directly after surgery and 6 h postoperatively.
RESULTS: Autologous retransfusion was performed in 50 patients (23%) in the retrospective analysis. Postoperative haemoglobin level was increased by 5 g dl (P = 0.017) in retransfused patients compared with those without retransfusion. However, there was no difference in the number of transfused allogeneic red blood cell concentrates. Mild adverse transfusion reactions were reported in 13 retransfused patients (26%). Laboratory analyses for the second prospective part detected massively elevated concentrations of myeloperoxidase and IL-6 in the drainage blood, but C-reactive protein and procalcitonin concentrations were within normal ranges at both time points. D-dimers levels were above the upper normal level in 37 and 24% at the two time points, respectively, and tended to decrease over time (P = 0.060).
CONCLUSION: Our study questions the effectiveness of postoperative autotransfusion as part of a patient blood management programme. In addition, the obvious signs of inflammatory reactions and coagulation activation raise safety concerns. TRIAL REGISTRATION: The cohort study was not registered in a trial registry.

Entities:  

Mesh:

Year:  2020        PMID: 31800406     DOI: 10.1097/EJA.0000000000001125

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  3 in total

1.  Incidence and risk factors for blood transfusion in simultaneous bilateral total hip arthroplasty.

Authors:  Xing Wang; Qiang Huang; Fuxing Pei
Journal:  Jt Dis Relat Surg       Date:  2021-11-19

2.  Impact of intraoperative allogenic and autologous transfusion on immune function and prognosis in patients with hepatocellular carcinoma.

Authors:  Youwei Gong; Yonglian Tang; Yinghong Xue; Ling Chen
Journal:  Medicine (Baltimore)       Date:  2020-10-09       Impact factor: 1.817

3.  A prospective randomized study, use of closed suction drainage after revision hip arthroplasty may lead to excessive blood loss.

Authors:  Paweł Bartosz; Dariusz Grzelecki; Sławomir Chaberek; Marcin Para; Wojciech Marczyński; Jerzy Białecki
Journal:  Sci Rep       Date:  2022-01-18       Impact factor: 4.379

  3 in total