Literature DB >> 31799979

Liver microphysiological systems development guidelines for safety risk assessment in the pharmaceutical industry.

Andreas R Baudy1, Monicah A Otieno2, Philip Hewitt3, Jinping Gan4, Adrian Roth5, Douglas Keller6, Radhakrishna Sura7, Terry R Van Vleet7, William R Proctor8.   

Abstract

The liver is critical to consider during drug development because of its central role in the handling of xenobiotics, a process which often leads to localized and/or downstream tissue injury. Our ability to predict human clinical safety outcomes with animal testing is limited due to species differences in drug metabolism and disposition, while traditional human in vitro liver models often lack the necessary in vivo physiological fidelity. To address this, increasing numbers of liver microphysiological systems (MPS) are being developed, however the inconsistency in their optimization and characterization often leads to models that do not possess critical levels of baseline performance that is required for many pharmaceutical industry applications. Herein we provide a guidance on best approaches to benchmark liver MPS based on 3 stages of characterization that includes key performance metrics and a 20 compound safety test set. Additionally, we give an overview of frequently used liver injury safety assays, describe the ideal MPS model, and provide a perspective on currently best suited MPS contexts of use. This pharmaceutical industry guidance has been written to help MPS developers and end users identify what could be the most valuable models for safety risk assessment.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31799979     DOI: 10.1039/c9lc00768g

Source DB:  PubMed          Journal:  Lab Chip        ISSN: 1473-0189            Impact factor:   6.799


  21 in total

1.  Prediction of hepatic drug clearance with a human microfluidic four-cell liver acinus microphysiology system.

Authors:  Courtney Sakolish; Yu-Syuan Luo; Alan Valdiviezo; Lawrence A Vernetti; Ivan Rusyn; Weihsueh A Chiu
Journal:  Toxicology       Date:  2021-09-17       Impact factor: 4.221

Review 2.  Organs-on-chips: into the next decade.

Authors:  Lucie A Low; Christine Mummery; Brian R Berridge; Christopher P Austin; Danilo A Tagle
Journal:  Nat Rev Drug Discov       Date:  2020-09-10       Impact factor: 84.694

3.  Variability in Human In Vitro Enzyme Kinetics.

Authors:  Christopher R Gibson; Ying-Hong Wang; Ninad Varkhede; Bennett Ma
Journal:  Methods Mol Biol       Date:  2021

4.  Analysis of reproducibility and robustness of a human microfluidic four-cell liver acinus microphysiology system (LAMPS).

Authors:  Courtney Sakolish; Celeste E Reese; Yu-Syuan Luo; Alan Valdiviezo; Mark E Schurdak; Albert Gough; D Lansing Taylor; Weihsueh A Chiu; Lawrence A Vernetti; Ivan Rusyn
Journal:  Toxicology       Date:  2020-12-08       Impact factor: 4.221

5.  Editorial overview of the special issue on application of tissue chips in toxicology.

Authors:  Ivan Rusyn; Adrian Roth
Journal:  Toxicology       Date:  2021-01-20       Impact factor: 4.221

Review 6.  Systems Modeling to Quantify Safety Risks in Early Drug Development: Using Bifurcation Analysis and Agent-Based Modeling as Examples.

Authors:  Carmen Pin; Teresa Collins; Megan Gibbs; Holly Kimko
Journal:  AAPS J       Date:  2021-05-20       Impact factor: 4.009

Review 7.  Quantifying the progression of non-alcoholic fatty liver disease in human biomimetic liver microphysiology systems with fluorescent protein biosensors.

Authors:  Manush Saydmohammed; Anupma Jha; Vineet Mahajan; Dillon Gavlock; Tong Ying Shun; Richard DeBiasio; Daniel Lefever; Xiang Li; Celeste Reese; Erin E Kershaw; Vijay Yechoor; Jaideep Behari; Alejandro Soto-Gutierrez; Larry Vernetti; Andrew Stern; Albert Gough; Mark T Miedel; D Lansing Taylor
Journal:  Exp Biol Med (Maywood)       Date:  2021-05-06

Review 8.  The Combination of Cell Cultured Technology and In Silico Model to Inform the Drug Development.

Authors:  Zhengying Zhou; Jinwei Zhu; Muhan Jiang; Lan Sang; Kun Hao; Hua He
Journal:  Pharmaceutics       Date:  2021-05-12       Impact factor: 6.321

9.  Characterizing the reproducibility in using a liver microphysiological system for assaying drug toxicity, metabolism, and accumulation.

Authors:  Andrés Rubiano; Amruta Indapurkar; Ryosuke Yokosawa; Alina Miedzik; Barry Rosenzweig; Ayesha Arefin; Chloe M Moulin; Keri Dame; Neil Hartman; Donna A Volpe; Murali K Matta; David J Hughes; David G Strauss; Tomasz Kostrzewski; Alexandre J S Ribeiro
Journal:  Clin Transl Sci       Date:  2021-04-03       Impact factor: 4.689

10.  A versatile microfluidic tool for the 3D culture of HepaRG cells seeded at various stages of differentiation.

Authors:  Manon Boul; Nassima Benzoubir; Antonietta Messina; Rasta Ghasemi; Ismail Ben Mosbah; Jean-Charles Duclos-Vallée; Anne Dubart-Kupperschmitt; Bruno Le Pioufle
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.