Literature DB >> 31797839

Comparison of Accuracy and Reliability of Working Length Determination Using Cone Beam Computed Tomography and Electronic Apex Locator: A Systematic Review.

Janki Amin1, Jordan Lines1, Maxim P Milosevic1, Andrew Park1, Amar Sholapurkar2.   

Abstract

AIM: To compare the accuracy and reliability of cone beam computed tomography (CBCT) and electronic apex locator (EAL) in determining the working length (WL).
BACKGROUND: A comprehensive literature search was conducted across several databases and gray literature. A total of 1,358 potentially relevant journal articles were identified with publication dates ranging from 1996 to 2017. After screening and applying the inclusion and exclusion criteria, five studies were identified as eligible for review. Data extraction was completed in two blinded pairs, cross-referenced and subsequently merged. Discrepancies were resolved through collaborator mediation. Meta-analysis was not undertaken due to heterogeneity between included studies. REVIEW
RESULTS: In all five studies, no statistically significant difference was found between CBCT and EAL measurements of WL. The reliability of CBCT compared with EAL was not determined.
CONCLUSION: Due to significant heterogeneity between the included studies, the accuracy of CBCT compared to EAL couldn't be determined. Based on limited evidence, CBCT appeared to be as accurate as EAL. There was weak evidence suggesting that CBCT was reliable. Also the superiority of one method over the other could not be determined. These results should be interpreted judiciously. Further research is required to conclusively evaluate the accuracy and reliability of CBCT compared with EAL. CLINICAL SIGNIFICANCE: Preexisting CBCT scans may be appropriate for WL determination but acquiring a new CBCT for endodontic treatment is inadvisable due to cost and the as low as reasonably achievable (ALARA) principle.

Entities:  

Keywords:  Cone beam computed tomography; Endodontics; Odontometry Root canal therapy.

Year:  2019        PMID: 31797839

Source DB:  PubMed          Journal:  J Contemp Dent Pract        ISSN: 1526-3711


  2 in total

Review 1.  Use of preoperative cone-beam computed tomography to aid in establishment of endodontic working length: A systematic review and meta-analysis.

Authors:  Andrew Paterson; Vittorio Franco; Shanon Patel; Federico Foschi
Journal:  Imaging Sci Dent       Date:  2020-09-16

Review 2.  Two decades of research on CBCT imaging in DMFR - an appraisal of scientific evidence.

Authors:  Hugo Gaêta-Araujo; André Ferreira Leite; Karla de Faria Vasconcelos; Reinhilde Jacobs
Journal:  Dentomaxillofac Radiol       Date:  2021-02-15       Impact factor: 2.419

  2 in total