Risk Factors Associated with Failure of Direct Cyclopexy in the Treatment of Small to Moderate Tramatic Cyclodialysis Clefts.

Ruijuan Zhao1, Bingsheng Lou1, Yao Yang1, Fang Duan1, Lixia Lin1, Miner Yuan1, Zhenfang Wang1, Liwen He1, Chongde Long1, Xiaofeng Lin1.   

Abstract

BACKGROUND: To evaluate the risk factors associated with failure to correct hypotony using direct cyclopexy in patients with traumatic cyclodialysis cleft.
METHODS: In a series of 116 patients with traumatic cyclodialysis who underwent direct cyclopexy at Zhongshan Ophthalmic Center from January 2008 to August 2018, the clinical correlation between the risk factors and failure of the operation were retrospectively studied, after adjusting for other potential confounders.
RESULTS: The curative ratio after one procedure was 82.76%, whereas 20 (17.24%) eyes experienced treatment failure after the first surgery. The degree of anterior chamber angle closure was significantly wider in patients with a failed first surgery than in patients for whom one procedure was a success (p = .046). The risk of failure to achieve closure increased as the angle-closure exceeded 5 clock hour (odds ratio, 10.39; 95% confidence interval, 1.75-61.72; p = .010). An analysis of the recurrent position indicated that an angle closure exceeding 5 clock hour may impede accurate cleft location and is thus associated with an increased risk of failure to correct hypotony.
CONCLUSION: Exceeding the threshold of 5 clock hour in anterior chamber angle closure may impede accurate cleft location and, thus, present a higher risk of failure to correct hypotony using direct cyclopexy. These patients may need injection of a viscoelastic agent into the anterior chamber by paracentesis to deepen the anterior chamber and to delineate the clefts using gonioscopy pre- or intraoperatively.

Entities:  

Keywords:  Traumatic cyclodialysis; angle closure; direct cyclopexy; hypotony

Mesh:

Year:  2019        PMID: 31797695     DOI: 10.1080/02713683.2019.1698052

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  2 in total

1.  Retina-sparing suprachoroidal intraocular foreign body resulting in cyclodialysis cleft.

Authors:  Colin P Kane; Thomas V Johnson; Mira M Sachdeva
Journal:  Am J Ophthalmol Case Rep       Date:  2022-05-03

2.  Invited Response on: Letter to the Editor: ''Standardized Three-Dimensional Lateral Distraction Test: Its Reliability to Assess Medial Canthal Tendon Laxity''.

Authors:  Xiaoyi Hou; Alexander C Rokohl; Yongwei Guo; Ludwig M Heindl
Journal:  Aesthetic Plast Surg       Date:  2021-10-04       Impact factor: 2.708

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.