Abstract

PURPOSES: This research aimed to investigate effects and risk factors on non-contact tonometer (NCT) readings in healthy myopic subjects by employing cross-sectional study design.
METHODS: Totally, sixty otherwise healthy myopic volunteers (mean 28.4 years old) with 90% female were recruited in ophthalmic clinic. The routine ophthalmic tests, refractive evaluation, examination central corneal thickness (CCT), depth of anterior chamber, axial length, corneal curvature, white-to-white and NCT were assessed at baseline. The linear-mixed model was utilized to evaluate correlation between the readings and ocular biometric parameters.
RESULTS: For population in this study, mean spherical equivalents were - 4.85 ± 1.79 diopters in right eyes and - 4.63 ± 1.95 diopters in left eyes. Meanwhile, 28.3% of the eyes had a refractive error exceeding - 6.0 diopters. The mean NCT reading was 15.02 ± 3.02 mmHg in left eyes and 15.33 ± 2.96 mmHg in right eyes. Among the factors analyzed, CCT was the most significant parameter associated with NCT readings. After adjusting for the other factors, per one standard deviation increase of central corneal thickness (36.11 μm) was associated a 1.14 (95% confidence interval 0.53-1.77) mmHg elevated NCT reading. The average central corneal curvature, age and spherical equivalence were also significantly and independently associated with NCT readings.
CONCLUSIONS: Central corneal thickness, age, corneal curvature and degree of myopia were independently associated with NCT measured intraocular pressure. Central corneal thickness is one of the most influential factors.

Entities:  

Keywords:  Central corneal thickness; Intraocular pressure; Myopia; Non-contact tonometer (NCT)

Mesh:

Year:  2019        PMID: 31792850     DOI: 10.1007/s10792-019-01203-8

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  29 in total

1.  Influence of age, central corneal thickness, and quality score on dynamic contour tonometry.

Authors:  M L S Jordão; A Pedroso de Carvalho Lupinacci; E L Ferreira; I J F Enomoto; V P Costa
Journal:  Eye (Lond)       Date:  2008-09-12       Impact factor: 3.775

2.  The Prevalence of Open-Angle Glaucoma by Age in Myopia: The Korea National Health and Nutrition Examination Survey.

Authors:  Seong Hee Shim; Kyung Rim Sung; Joon Mo Kim; Hyun Tae Kim; Jinho Jeong; Chan Yun Kim; Mi Yeon Lee; Ki Ho Park
Journal:  Curr Eye Res       Date:  2016-06-01       Impact factor: 2.424

3.  Novel microsurgical management of uveitis-glaucoma-hyphema syndrome.

Authors:  Vytautas Jasinskas; Renata Vaiciuliene; Aiste Varoniukaite; Martynas Speckauskas
Journal:  Int Ophthalmol       Date:  2018-06-26       Impact factor: 2.031

4.  Relationship of Intraocular Pressure with Central Aortic Systolic Pressure.

Authors:  Andrew S H Tsai; Tin Aung; Wanfen Yip; Tien Yin Wong; Carol Yim-Lui Cheung
Journal:  Curr Eye Res       Date:  2015-05-05       Impact factor: 2.424

5.  Peripapillary schisis in open-angle glaucoma.

Authors:  N Dhingra; R Manoharan; S Gill; M Nagar
Journal:  Eye (Lond)       Date:  2016-11-11       Impact factor: 3.775

6.  Corneal astigmatism in applanation tonometry.

Authors:  H H Mark; T L Mark
Journal:  Eye (Lond)       Date:  2003-07       Impact factor: 3.775

7.  Postural and diurnal fluctuations in intraocular pressure across the spectrum of glaucoma.

Authors:  Natasha Gautam; Savleen Kaur; Sushmita Kaushik; Srishti Raj; Surinder Singh Pandav
Journal:  Br J Ophthalmol       Date:  2015-08-12       Impact factor: 4.638

8.  The Relationship between Visual Field Global Indices and Retinal Nerve Fiber Layer Thickness in Healthy Myopes.

Authors:  Yuan-Zhi Yuan; Chen-Li Feng; Bao-Yue Li; Min-Qian Shen; Xiu-Ping Chen; Chen-Hao Zhang; Chun-Qiong Dong; Fei Yuan
Journal:  J Ophthalmol       Date:  2014-11-10       Impact factor: 1.909

9.  Comparison of intraocular pressure as measured by three different non-contact tonometers and goldmann applanation tonometer for non-glaucomatous subjects.

Authors:  Seung Pil Bang; Chong Eun Lee; Yu Cheol Kim
Journal:  BMC Ophthalmol       Date:  2017-11-02       Impact factor: 2.209

Review 10.  Intraocular pressure and glaucoma: Is physical exercise beneficial or a risk?

Authors:  Charles William McMonnies
Journal:  J Optom       Date:  2016-01-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.