Literature DB >> 31791513

The impact of UV treatment on microbial control and DBPs formation in full-scale drinking water systems in northern China.

Xiuwei Ao1, Zhongyun Chen1, Simiao Li1, Chen Li1, Zedong Lu1, Wenjun Sun2.   

Abstract

To manage potential microbial risks and meet increasingly strict drinking water health standards, UV treatment has attracted increasing attention for use in drinking water systems in China. However, the effects of UV treatment on microbial control and disinfection by-products (DBPs) formation in real municipal drinking water systems are poorly understood. Here, we collected water samples from three real drinking water systems in Beijing and Tianjin to investigate the impacts of UV treatment on microbial control and DBP formation. We employed heterotrophic plate count (HPC), flow cytometry (FCM), quantitative PCR analysis, and high-throughput sequencing to measure microorganisms in the samples. Different trends were observed between HPC and total cell count (measured by FCM), indicating that a single indicator could not reflect the real degree of biological re-growth in drinking water distribution systems (DWDSs). A significant increase in the 16S rRNA gene concentration was observed when the UV system was stopped. Besides, the bacterial community composition was similar at the phylum level but differed markedly at the genera level among the three DWDSs. Some chlorine-resistant bacteria, including potential pathogens (e.g., Acinetobacter) showed a high relative abundance when the UV system was turned off. It can be concluded that UV treatment can mitigate microbial re-growth to some extent. Finally, UV treatment had a limited influence on the formation of DBPs, including trihalomethanes, haloacetic acids, and nitrogenated DBPs. The findings of this study may help to understand the performance of UV treatment in real drinking water systems.
Copyright © 2019. Published by Elsevier B.V.

Entities:  

Keywords:  Bacterial community; Disinfection by-products (DBPs); Multi-barrier disinfection; Municipal drinking water systems; UV treatment

Mesh:

Substances:

Year:  2019        PMID: 31791513     DOI: 10.1016/j.jes.2019.08.003

Source DB:  PubMed          Journal:  J Environ Sci (China)        ISSN: 1001-0742            Impact factor:   5.565


  2 in total

Review 1.  Microbial diversity in full-scale water supply systems through sequencing technology: a review.

Authors:  Wei Zhou; Weiying Li; Jiping Chen; Yu Zhou; Zhongqing Wei; Longcong Gong
Journal:  RSC Adv       Date:  2021-07-22       Impact factor: 4.036

2.  Photooxidation of atrazine and its influence on disinfection byproducts formation during post-chlorination: effect of solution pH and mechanism.

Authors:  Yucan Liu; Kai Zhu; Huayu Zhu; Min Zhao; Lihua Huang; Bin Dong; Qianjin Liu
Journal:  Sci Rep       Date:  2020-11-23       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.