| Literature DB >> 31789079 |
Mario D'Oria1, Aleem K Mirza1, Emanuel R Tenorio1, Jussi M Kärkkäinen1, Randall R DeMartino1, Gustavo S Oderich1.
Abstract
Purpose: To demonstrate the feasibility of a physician-modified endograft (PMEG) with inner branches for 2 mesenteric arteries as an alternative to fenestrations or directional branches. Technique: A symptomatic 60-year-old man presented with supraceliac para-anastomotic pseudoaneurysm involving an antegrade aorta to celiac artery and superior mesenteric artery bypass. Since an off-the-shelf multibranched endograft was inappropriate, a Zenith Alpha thoracic stent-graft was modified with 2 inner branches fashioned of 8-mm Viabahn endoprostheses with preloaded guidewires. The procedure was technically successful, and the patient had no postoperative complications.Entities:
Keywords: branched stent-graft; fenestrated stent-graft; inner branches; para-anastomotic aneurysm; physician-modified stent-graft; renovisceral vessels; surgeon-modified stent-graft; target artery; thoracic endovascular aortic repair; thoracoabdominal aortic aneurysm
Year: 2019 PMID: 31789079 DOI: 10.1177/1526602819890108
Source DB: PubMed Journal: J Endovasc Ther ISSN: 1526-6028 Impact factor: 3.487