Literature DB >> 31785036

Cuffed pediatric endotracheal tubes-Outer cuff diameters compared to age-related airway dimensions.

Martina Fischer1, Beate Grass2, Michael Kemper1, Markus Weiss1, Mital H Dave1.   

Abstract

BACKGROUND: Reliable sealing of the pediatric airway requires appropriately sized tracheal tube cuffs. The aim of this study was to compare residual cuff diameters of pediatric tracheal tubes with pediatric airway dimensions.
METHODS: Cuff diameters of five different brands of locally marketed pediatric cuffed tracheal tubes with internal diameters of 3.0-7.0 mm were measured at a cuff pressure of 20 cm H2 O and compared with cuff diameters indicated by their manufacturers. The latter values were compared to tracheal dimensions using the Motoyama and Khine formulas for cuffed tracheal tube size selection.
RESULTS: There is considerable heterogeneity in cuff diameters among pediatric tracheal tube brands, except for two brands from different manufacturers (Halyard and Parker Medical) which were identically designed. Cuffs made from polyurethane revealed fewer differences (91%-118%) between measured and manufacturer-indicated values for outer cuff diameters than did those made from polyvinylchloride (91%-146%). Particularly in smaller sized tracheal tubes, cuffs did not reach 100% of the tracheal lateral diameter, while others were oversized in larger tracheal tubes, independent of the two formulas used for cuffed tracheal tube size selection. Cuff diameters indicated by the manufacturer corresponded to 86%-188% of the median and 68%-157% of the maximum mid-tracheal lateral diameter of the corresponding upper age range.
CONCLUSION: Our findings show that many of the cuff diameters of currently marketed tracheal tube brands lack an age-related anatomical rationale. A proposal for age-related anatomically based cuff diameters is provided for both recommendations for cuffed tracheal tube size selection in children.
© 2019 John Wiley & Sons Ltd.

Entities:  

Keywords:  airway; airwayq equipment; pediatric

Mesh:

Year:  2020        PMID: 31785036     DOI: 10.1111/pan.13776

Source DB:  PubMed          Journal:  Paediatr Anaesth        ISSN: 1155-5645            Impact factor:   2.556


  1 in total

1.  Prediction of endotracheal tube size using a printed three-dimensional airway model in pediatric patients with congenital heart disease: a prospective, single-center, single-group study.

Authors:  Seyeon Park; Jisoo Ahn; Sung Uk Yoon; Ki Seok Choo; Hye-Jin Kim; Minwoo Chung; Hee Young Kim
Journal:  Korean J Anesthesiol       Date:  2021-05-31
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.