Kinematic Performance of Gradually Variable Radius Posterior-Stabilized Primary TKA During Various Activities: An In Vivo Study Using Fluoroscopy.

Milad Khasian1, Adrija Sharma1, Thomas K Fehring2, William L Griffin2, J Bohannon Mason2, Richard D Komistek1.   

Abstract

BACKGROUND: Posterior-stabilized total knee arthroplasty (TKA) with gradually variable radii (G-curve) femoral condylar geometry is now available. It is believed that a G-curve design would lead to more mid-flexion stability leading to reduced incidence of paradoxical anterior slide. The objective of this study was to assess the in vivo kinematics for subjects implanted with this type of TKA under various conditions of daily living.
METHODS: Tibiofemoral kinematics of 35 patients having posterior-stabilized TKA with G-curve design were analyzed using fluoroscopy while performing three activities: weight-bearing deep knee bend, gait, and walking down a ramp. The subjects were assessed for range of motion, condylar translation, axial rotation, cam-spine engagement, and condylar lift-off.
RESULTS: The average weight-bearing flexion during deep knee bend was 111.4°. On average, the subjects exhibited 5.4 mm of posterior rollback of the lateral condyle and 2.0 mm of the medial condyle from full extension to maximum knee flexion. The femur consistently rotated externally with flexion, and the average axial rotation was 5.2°. Overall movement of the condyles during gait and ramp-down activity was small. No incidence of condylar lift-off was observed.
CONCLUSION: Subjects in this study experienced consistent magnitudes of posterior femoral rollback and external rotation of the femur with weight-bearing flexion. The variation is similar to that previously reported for normal knee where the lateral condyle moves consistently posterior compared to the medial condyle. Subjects experienced low overall mid-flexion paradoxical anterior sliding and no incidence of condylar lift-off leading to mid-flexion stability.
Copyright © 2019 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  gradually variable radius; kinematics; mobile fluoroscopy; posterior stabilized; total knee arthroplasty

Year:  2019        PMID: 31784361     DOI: 10.1016/j.arth.2019.10.053

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  2 in total

1.  Alterations of kinematics in knees after single versus multiple radius femoral prostheses total knee arthroplasty: a retrospective study.

Authors:  Mengyuan Li; Guangtao Fu; Wenhan Huang; Bofu Lin; Ruiying Zhang; Yu Zhang; Yuanchen Ma; Qiujian Zheng
Journal:  BMC Musculoskelet Disord       Date:  2020-07-04       Impact factor: 2.362

2.  A Short-Term Multicenter Analysis of Radiolucent Lines in a Single Uncemented Rotating Platform Implant for Total Knee Arthroplasty.

Authors:  Jason Desmarais; David Dalury; Thomas L Bernasek; David A Fisher; Ryan M Nunley; Marie-Claire Fickenscher; Robert S Gorab
Journal:  Arthroplast Today       Date:  2022-04-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.