Literature DB >> 31782541

Ultrasound Microflow Imaging Technology for Diagnosis of Adhesive Capsulitis of the Shoulder.

Dong Hyun Kim1, Yoon-Hee Choi2, Sohee Oh3, Hyo Jin Kim1, Jee Won Chai1.   

Abstract

OBJECTIVES: To assess the diagnostic accuracy of Superb Microvascular Imaging (SMI; Canon Medical Systems, Otawara, Japan) at the subcoracoid triangle for adhesive capsulitis of the shoulder, to compare the diagnostic value of SMI with that of conventional ultrasound (US) and power Doppler ultrasound (PDUS) findings, and to investigate the correlation between vascular flow on SMI with clinical features.
METHODS: Our study included 39 patients with a diagnosis of adhesive capsulitis and 35 healthy patients as a control group. The echogenicity in the rotator interval and coracohumeral ligament thickness were assessed with conventional US. Vascular flow in the subcoracoid fat triangle was evaluated with SMI and PDUS (SMI and PDUS areas). A receiver operating characteristic curve analysis was performed to evaluate diagnostic accuracy. The correlation between US findings and the range of motion, pain intensity, and duration of symptoms was also evaluated.
RESULTS: The SMI area was higher in the adhesive capsulitis group than in the control group (2.95 versus 0 mm2 ; P < .01). The visualization of vascular flow at the subcoracoid fat triangle was superior with SMI compared with PDUS (P < .01). In the receiver operating characteristic analysis, the SMI area showed higher diagnostic performance, with an area under the curve of 0.90 compared with other US findings. The area of SMI vascular flow was also negatively correlated with external rotation and forward flexion (P < .05) in the adhesive capsulitis group.
CONCLUSIONS: Measurement of vascular flow at the subcoracoid fat triangle using SMI facilitated the diagnosis of adhesive capsulitis. Superb Microvascular Imaging was superior to PDUS in diagnostic performance. Vascular flow was negatively correlated with the range of motion of external rotation and forward flexion.
© 2019 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  Doppler; adhesive capsulitis; diagnosis; shoulder joint; ultrasound

Year:  2019        PMID: 31782541     DOI: 10.1002/jum.15181

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

1.  Evaluation of hypervascularity in synovitis of the shoulder using ultrasound: comparison of preoperative ultrasound findings and intraoperative arthroscopic findings.

Authors:  Akira Inoue; Tadanao Funakoshi; Ryuji Koga; Hiroshi Kusano; Toru Takahashi; Azusa Miyamoto; Toshiki Murayama; Yuta Kainuma; Saki Koda; Keito Kawanabe; Yuzuru Yamamoto
Journal:  JSES Int       Date:  2022-01-25

2.  Diagnostic accuracy of ultrasound superb microvascular imaging for parotid tumors: A protocol for systematic review and meta-analysis.

Authors:  Jili Zhang; Jialing Wu; Xiukun Hou
Journal:  Medicine (Baltimore)       Date:  2021-01-29       Impact factor: 1.817

3.  High-frequency ultrasound in the 21st century.

Authors:  Robert Krzysztof Mlosek; Bartosz Migda; Michał Migda
Journal:  J Ultrason       Date:  2020-12-18

Review 4.  [Adhesive Capsulitis of the Shoulder].

Authors:  Soo-Jung Choi
Journal:  Taehan Yongsang Uihakhoe Chi       Date:  2021-11-30
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.