Effect of mucosa thicknesses on stress distribution of implant-supported overdentures under unilateral loading: Photoelastic analysis.

Ozgun Yusuf Ozyilmaz1, Filiz Aykent2, Gulsum Sayin Ozel3.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the effect of different heights of attachment and mucosa thicknesses on the stress distribution of two implant-retained mandibular overdenture designs under loading using the photoelastic stress analysis method.
MATERIALS AND METHODS: Six photoelastic models of an edentulous mandibula were fabricated with two solitary implants that were placed in the canine regions. The attachment systems studied were ball and locator stud attachments. Both the ball and locator groups included three models that had different residual ridge heights so as to provide different mucosa thicknesses (1 mm-1 mm, 1 mm-2 mm, 1 mm-4 mm). A static vertical force of 135 N was applied unilaterally (each on the right then the left side) to the central fossa of the first molars. Models were positioned in the field of a circular polariscope to observe the distribution of isochromatic fringes around the implants and the interimplant areas under loading. The photoelastic stress fringes were monitored and recorded photographically.
RESULTS: The ball attachment groups showed higher stress values than did the locator groups under loading. Both attachment systems produced the lowest stress values in stimulated 1 mm-1 mm mucosa thickness models. The models with 1 mm-2 mm mucosa thicknesses showed higher stress values than did other models for both attachment systems. The highest stress value observed around both attachment systems was the moderate level in all test models.
CONCLUSION: In different height mucosa thicknesses, locator attachment models distributed the load to the other side of the implant and its surrounding tissue, whereas the ball attachment did not. Regardless of mucosal thickness and attachment type, the implant on the loading side was subjected to the highest stress concentration.

Entities:  

Keywords:  Solitary implants; abutment height; mucosa thickness; photoelastic analysis; stress distribution

Mesh:

Substances:

Year:  2019        PMID: 31779504     DOI: 10.1177/2280800019882645

Source DB:  PubMed          Journal:  J Appl Biomater Funct Mater        ISSN: 2280-8000            Impact factor:   2.604


  1 in total

Review 1.  Bioengineering Tools Applied to Dentistry: Validation Methods for In Vitro and In Silico Analysis.

Authors:  Jefferson David Melo de Matos; Daher Antonio Queiroz; Leonardo Jiro Nomura Nakano; Valdir Cabral Andrade; Nathália de Carvalho Ramos Ribeiro; Alexandre Luiz Souto Borges; Marco Antonio Bottino; Guilherme da Rocha Scalzer Lopes
Journal:  Dent J (Basel)       Date:  2022-08-04
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.