| Literature DB >> 31771572 |
Billy Ngasala1,2, Samweli Bushukatale3.
Abstract
BACKGROUND: The World Health Organization (WHO) recommends use of parasitological diagnosis of malaria for all age groups in all malaria transmission settings. Many private health facilities rely on malaria microscopy for malaria diagnosis. However, quality of malaria microscopy is affected by number of factors including availability of skilled laboratory microscopists and lack of quality assurance systems in many malaria endemic countries. This study was carried out to assess quality of malaria microscopy in selected private health facilities in Tanzania.Entities:
Keywords: Malaria; Microscopy; Performance; Private health facilities
Mesh:
Year: 2019 PMID: 31771572 PMCID: PMC6880513 DOI: 10.1186/s12936-019-2998-1
Source DB: PubMed Journal: Malar J ISSN: 1475-2875 Impact factor: 2.979
Characteristics of surveyed private health facilities and microscopists
| Characteristic | Health facility (N = 31) | |
|---|---|---|
| (N = 31) | Percentage | |
| Type of health facility | ||
| Autonomous laboratories | 9 | 29.0 |
| Dispensaries | 11 | 35.5 |
| Health centres | 9 | 29.0 |
| Hospitals | 2 | 6.5 |
| Number of health facilities per region | ||
| Mara | 7 | 22.5 |
| Ruvuma | 6 | 19.3 |
| Kilimanjaro | 8 | 25.8 |
| Mbeya | 6 | 19.3 |
| Songwe | 5 | 16.1 |
Overall performance of private health facilities microscopists in detection of malaria parasites compared to the experienced microscopists
| PHF readers | Experienced reader | |
|---|---|---|
| Positive | Negative | |
| Positive | 113 | 9 |
| Negative | 21 | 89 |
| Sensitivity % (95% CI) | 84.3% (77–90%) | |
| Specificity % (95% CI) | 90.8% (83.3–95.7%) | |
PHF private health facility, CI confidence interval
Evaluation of the performance of microscopists in detection of malaria parasites according to the type of health facility
| Type of health facility | Number of microscopists | Sensitivity % | Specificity % | Agreement | Kappa value | |
|---|---|---|---|---|---|---|
| % 95% CI | % 95% CI | % | ĸ | 95% CI | ||
| Autonomous laboratory | 9 | 86.7 (73.2–94.9) | 88.2 (72.5–96.7) | 87.3 | 0.74 | (0.60–0.89) |
| Dispensary | 11 | 81.5 (68.6–90.7) | 87.9 (71.8–96.6) | 83.9 | 0.67 | (0.51–0.83) |
| Health centre | 9 | 86.2 (68.3–96.1) | 95.8 (78.9–99.9) | 90.6 | 0.81 | (0.66–0.97) |
| Hospital | 2 | 83.3 (35.9–99.6) | 100 (59–100) | 92.3 | 0.84 | (0.60–1.00) |
CI confidence interval
Classification of parasite quantification at different levels of private health laboratories compared to parasite density panel slides readings at MUHAS
| Microscopists’ results | Low-medium density panel slides | High density panel slides | ||
|---|---|---|---|---|
| Slides (n) | % | Slides (n) | % | |
| All facilities | (N = 54) | (N = 80) | ||
| Low-medium | 30 | 55.5a | 37 | 46.3 |
| High | 9 | 16.7 | 37 | 46.3b |
| Negative | 15 | 27.8 | 6 | 7.5 |
| Autonomous laboratory | (N = 23) | (N = 31) | ||
| Low-medium | 15 | 65.2a | 13) | 41.9 |
| High | 3 | 13.0 | 13 | 41.9b |
| Negative | 5 | 21.7 | 5 | 16.1 |
| Dispensary | (N = 19) | (N = 26) | ||
| Low-medium | 10 | 52.6a | 15 | 57.7 |
| High | 3 | 15.8 | 11 | 42.3b |
| Negative | 6 | 31.6 | 0 | 0 |
| Health centre | (N = 10) | (N = 19) | ||
| Low-medium | 5 | 50a | 9 | 47.4 |
| High | 2 | 20 | 9 | 47.4b |
| Negative | 3 | 30 | 1 | 5.2 |
| Hospital | (N = 2) | (N = 4) | ||
| Low-medium | 0 | 0a | 0 | |
| High | 1 | 50 | 4 | 100b |
| Negative | 1 | 50 | 0 | |
aCorrectly classified as low to medium parasite density slide
bCorrectly classified as High parasite density slide
Factors associated with correct performance in quantification of malaria parasites by microscopists in selected private health laboratories in Tanzania
| Variable name | Univariate | Multivariate | ||||
|---|---|---|---|---|---|---|
| OR | 95% CI | aOR | 95% CI | |||
| Qualification | ||||||
| Certificate | 1 | 1 | ||||
| Diploma | 0.338 | 0.075–1.525 | 0.158 | 1.239 | 0.196–7.835 | 0.82 |
| Adv. diploma | 0.754 | 0.166–3.3430 | 0.716 | 1.668 | 0.242–11.488 | 0.602 |
| Experience (years) | ||||||
| 0–2 | 1 | 1 | ||||
| 2–5 | 0.5 | 0.104–2. 403 | 0.387 | 0.472 | 0.073–3.056 | 0.431 |
| > 5 | 1.103 | 0.277–4.39 | 0.889 | 1.089 | 0.151–7.862 | 0.932 |
| Onjob training (yes) | 4.47 | 1.772–11.275 | 0.002 | 8.04 | 2.197–29.425 | 0.002* |
| Type of lab | ||||||
| Dispensary | 1 | 1 | ||||
| Autonomous lab | 0.811 | 0.281–2.234 | 0.697 | 0.344 | 0.793–1.496 | 0.155 |
| Health centre/hospital | 1.1 | 0.375–3.226 | 0.862 | 1.339 | 0.372–4.829 | 0.655 |
OR crude odds ratio, aOR adjusted odds ratio, CI confidence interval
* Significant at P-value < 0.05