Literature DB >> 31770649

Effect of aeration mode on aerosol characteristics from the same wastewater treatment plant.

Yunping Han1, Tang Yang2, Xu Yan3, Lin Li4, Junxin Liu5.   

Abstract

Aeration and mechanical agitation are the main drivers of aerosol generation in wastewater treatment plants (WWTPs). However, the effect of aeration mode on aerosol characteristics remains poorly understood. In this study, horizontal rotor aeration and fine bubble aeration in the same WWTP were selected to identify the effect on the emission, size distribution, microbial and chemical composition. For bacteria, fungi, Enterobacteriaceae, Staphylococcus aureus, and Pseudomonas aeruginosa in aerosols, the horizontal rotor aeration had higher contributions to the emissions than the fine bubble aeration. Horizontal rotor aeration generated a more coarse fraction (size > 7 μm) and a comparable respirable fraction (RF; size < 3.3 μm) compared with those of fine bubble aeration. More types of potential pathogens were generated by horizontal rotor aeration. The most easily aerosolized genera generated by horizontal rotor aeration and fine bubble aeration, were Trichosporon and Mycobacterium, with the aerosolization factors of 633.70 and 192.56, respectively. For Cl-, SO42-, NO3-, Zn, Ba, Cd, Sc, V, Rb, Ca, K, Ca, K, Mg, Na and Si in the aerosols, the contributions of fine bubble aeration were higher than those of horizontal rotor aeration. Due to the aerosol specialty from the different aeration modes, targeted manipulations should be employed to reduce the exposure risks.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Aerosols; Characteristics; Fine bubble aeration; Horizontal rotor aeration; Wastewater treatment plant

Mesh:

Substances:

Year:  2019        PMID: 31770649     DOI: 10.1016/j.watres.2019.115324

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  5 in total

1.  What are the disease burden and its sensitivity analysis of workers exposing to Staphylococcus aureus bioaerosol during warm and cold periods in a wastewater treatment plant?

Authors:  Jiaxin Ma; Dongzi An; Beibei Cui; Manli Liu; Hao Zhu; Ming Li; Xiaojun Ai; Wajid Ali; Cheng Yan
Journal:  Environ Sci Pollut Res Int       Date:  2022-06-27       Impact factor: 5.190

Review 2.  Where do we stand to oversee the coronaviruses in aqueous and aerosol environment? Characteristics of transmission and possible curb strategies.

Authors:  Bin Ji; Yaqian Zhao; Abraham Esteve-Núñez; Ranbin Liu; Yang Yang; Ange Nzihou; Yiping Tai; Ting Wei; Cheng Shen; Yan Yang; Baimimng Ren; Xingxing Wang; Ya'e Wang
Journal:  Chem Eng J       Date:  2020-10-27       Impact factor: 13.273

3.  Occurrence and decay of SARS-CoV-2 in community sewage drainage systems.

Authors:  Qian Dong; Jun-Xiong Cai; Yan-Chen Liu; Hai-Bo Ling; Qi Wang; Luo-Jing Xiang; Shao-Lin Yang; Zheng-Sheng Lu; Yi Liu; Xia Huang; Jiu-Hui Qu
Journal:  Engineering (Beijing)       Date:  2022-04-20       Impact factor: 12.834

Review 4.  Bioaerosol emissions from activated sludge basins: Characterization, release, and attenuation.

Authors:  Adam C Burdsall; Yun Xing; Casey W Cooper; Willie F Harper
Journal:  Sci Total Environ       Date:  2020-08-20       Impact factor: 7.963

5.  Possible transmission of viruses from contaminated human feces and sewage: Implications for SARS-CoV-2.

Authors:  Mohamed Elsamadony; Manabu Fujii; Takayuki Miura; Toru Watanabe
Journal:  Sci Total Environ       Date:  2020-09-29       Impact factor: 7.963

  5 in total