Literature DB >> 31769565

Texture Analysis of High b-Value Diffusion-Weighted Imaging for Evaluating Consistency of Pituitary Macroadenomas.

Chun-Qiu Su1, Xuan Zhang1, Ting Pan1, Xiao-Tian Chen1, Wen Chen1, Shao-Feng Duan2, Jing Ji1, Wei-Xing Hu1, Shan-Shan Lu1, Xun-Ning Hong1.   

Abstract

BACKGROUND: Preoperative evaluation of the consistency of pituitary macroadenomas is important for neurosurgeons to prepare the surgical plan.
PURPOSE: To evaluate the diagnostic performance of texture analysis (TA) of diffusion-weighted imaging (DWI) at a standard b-value (b = 1000 s/mm2 ) and a high b-value (b = 2000 s/mm2 ) for their ability to assess the tumor consistency of pituitary macroadenomas. STUDY TYPE: Retrospective. POPULATION/
SUBJECTS: Fifty patients with histologically confirmed pituitary macroadenomas were classified as soft (n = 37) or hard (n = 13) types. FIELD STRENGTH/SEQUENCE: Coronal T2 -weighted imaging (T2 WI), Readout Segmentation of Long Variable Echo-trains (RESOLVE) DWI at b = 1000 s/mm2 and b = 2000 s/mm2 were acquired with 3.0T MRI. ASSESSMENT: The corresponding apparent diffusion coefficient (ADC) maps (ADC1000 and ADC2000 ) were registered to T2 WI. Regions of interest (ROIs) were manually drawn along the solid part of the tumor from the coregistered T2 WI-ADC images. The texture parameters from T2 WI, ADC1000 , and ADC2000 were acquired. STATISTICAL TESTS: The texture parameters were compared between the two types by using unpaired Student's t-test. Receiver operating characteristic (ROC) curves and logistic regression analyses were used to assess their diagnostic performance.
RESULTS: Significant differences in TA parameters of ADC1000 and ADC2000 were observed between soft and hard types (P < 0.05 for all), whereas the TA of T2 WI resulted in no significant difference (P > 0.05 for all). TA of ADC2000 provided a superior diagnostic performance compared with that of ADC1000 (P = 0.038). A combination of mean value and entropy of ADC2000 yielded an AUC, a sensitivity, and a specificity of 0.911, 78.4% and 92.3%, respectively. DATA
CONCLUSION: TA of ADC values were useful for assessing the tumor consistency of pituitary macroadenomas. ADC2000 may facilitate better type discrimination. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2020;51:1507-1513.
© 2019 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  high b-value diffusion-weighted imaging; pituitary macroadenomas; texture analysis

Mesh:

Year:  2019        PMID: 31769565     DOI: 10.1002/jmri.26941

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  2 in total

1.  Texture analysis of conventional magnetic resonance imaging and diffusion-weighted imaging for distinguishing sinonasal non-Hodgkin's lymphoma from squamous cell carcinoma.

Authors:  Guo-Yi Su; Jun Liu; Xiao-Quan Xu; Mei-Ping Lu; Min Yin; Fei-Yun Wu
Journal:  Eur Arch Otorhinolaryngol       Date:  2022-06-22       Impact factor: 2.503

Review 2.  Machine Learning for the Detection and Segmentation of Benign Tumors of the Central Nervous System: A Systematic Review.

Authors:  Paul Windisch; Carole Koechli; Susanne Rogers; Christina Schröder; Robert Förster; Daniel R Zwahlen; Stephan Bodis
Journal:  Cancers (Basel)       Date:  2022-05-27       Impact factor: 6.575

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.