Literature DB >> 31767349

A novel signal amplification strategy based on the competitive reaction between 2D Cu-TCPP(Fe) and polyethyleneimine (PEI) in the application of an enzyme-free and ultrasensitive electrochemical immunosensor for sulfonamide detection.

Jiaxuan Xiao1, Xialin Hu2, Kun Wang3, Yanmin Zou4, Eric Gyimah1, Salome Yakubu1, Zhen Zhang5.   

Abstract

Nanozymes with peroxidase-like activity have been widely used as signal labels in electrochemical immunosensors. However, these sensors always suffer from some shortcomings during the processes underlying nanozyme labeling, including complex reactions, nanozyme inactivation after being decorated on the antibodies. To solve these problems, a novel electrochemical immunosensor was designed for ultrasensitive detection of sulfonamides (SAs), in which the synthesized 2D Cu-TCPP(Fe) with peroxidase-like property was used as a nanozyme that was directly modified on the electrode surface. Meanwhile, the structure of 2D Cu-TCPP(Fe) could be destroyed by the polyethyleneimine (PEI) from PEI-GO@Ab2 due to the stronger affinity between PEI and Cu2+, leading to an activity change of the prepared nanozyme. When H2O2 was introduced to the system, the electrochemical current was significantly declined owing to the peroxidase activity of 2D Cu-TCPP(Fe) decreased, which led to signal amplifications. Under the optimized conditions, this strategy had a wide detection range (1.186-28.051 ng/mL), satisfactory accuracy and precision (recoveries, 64-118%; CV, 2.16-7.27%) with a low detection limit of 0.395 ng/mL. The findings of this study indicate that the electrochemical immunosensor we developed has great potential and can be used for enzyme-free detection of SAs in environmental samples.
Copyright © 2019. Published by Elsevier B.V.

Entities:  

Keywords:  Electrochemical biosensor; Immunoassay; Nanozyme; Signal amplification; Sulfonamides

Mesh:

Substances:

Year:  2019        PMID: 31767349     DOI: 10.1016/j.bios.2019.111883

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

1.  A label-free electrochemical immunosensor based on a gold-vertical graphene/TiO2 nanotube electrode for CA125 detection in oxidation/reduction dual channels.

Authors:  Zehua Chen; Bingbing Li; Jinbiao Liu; Hongji Li; Cuiping Li; Xiuwei Xuan; Mingji Li
Journal:  Mikrochim Acta       Date:  2022-06-14       Impact factor: 5.833

Review 2.  Recent Advances and Perspectives on the Sources and Detection of Antibiotics in Aquatic Environments.

Authors:  Yanbo Zeng; Fengqin Chang; Qi Liu; Lizeng Duan; Donglin Li; Hucai Zhang
Journal:  J Anal Methods Chem       Date:  2022-05-25       Impact factor: 2.594

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.