Literature DB >> 31765245

Evaluation of Tear Fluid and Aqueous Humor Concentration of Clusterin as Biomarkers for Early Diagnosis of Pseudoexfoliation Syndrome and Pseudoexfoliative Glaucoma.

Birsen Can Demirdöğen1, Sinem Demirkaya-Budak1, Gökhan Özge2, Tarkan Mumcuoğlu2.   

Abstract

PURPOSE: Pseudoexfoliation syndrome (PEX) is an age-related disorder of the extracellular matrix characterized by the accumulation of fibrillary deposits in the anterior chamber of the eye, which leads to the development of pseudoexfoliative glaucoma (PEG). Early identification of subjects with higher susceptibility to PEX and PEG development is very important so that these conditions are managed at earlier stages, which requires that an objective biomarker is defined. Therefore, in the present study, we aimed to determine if aqueous humor and tear fluid concentrations of clusterin, an extracellular chaperone, are objective biomarkers for PEX and PEG risk.
METHODS: Tear fluid was obtained from 80 patients with PEG, 80 patients with PEX, and 80 controls, using Schirmer strips. Aqueous humor was also collected during cataract surgery from 12 patients with PEG, 17 patients with PEX, and 22 controls, who also gave tear samples. Clusterin concentration was determined by ELISA.
RESULTS: Clusterin concentration in aqueous humor was significantly higher in patients with PEG than in PEX cases (P = .002) and controls (P = .004). Receiver operating characteristics analysis revealed that this parameter is a robust classifier to distinguish PEG and PEX cases. Tear fluid clusterin concentrations did not differ significantly between groups. Aqueous humor and tear fluid levels of clusterin were not significantly correlated.
CONCLUSIONS: In conclusion, tear fluid clusterin level in patients with PEG and PEX was determined for the first time, which showed no difference between study groups. Aqueous humor clusterin level was markedly higher in patients with PEG.

Entities:  

Keywords:  Aqueous humor; biomarker; clusterin; pseudoexfoliation glaucoma; tear fluid

Mesh:

Substances:

Year:  2019        PMID: 31765245     DOI: 10.1080/02713683.2019.1698055

Source DB:  PubMed          Journal:  Curr Eye Res        ISSN: 0271-3683            Impact factor:   2.424


  2 in total

1.  Aqueous humor and serum levels of 4-hydroxynonenal and 8-hydroxy-2'deoxyguanosine in pseudoexfoliation syndrome and glaucoma.

Authors:  Nurullah Koçak; Ertuğrul Can; Volkan Yeter; Mustafa Turunç; Mustafa Subaşı; Leyla Niyaz; Bahattin Avcı
Journal:  Int Ophthalmol       Date:  2022-10-04       Impact factor: 2.029

2.  Evaluation of aqueous humor and serum clusterin levels in patients with glaucoma.

Authors:  Fuat Yavrum; Ufuk Elgin; Zeynep Adiyaman Kocer; Vildan Fidanci; Emine Sen
Journal:  BMC Ophthalmol       Date:  2021-01-09       Impact factor: 2.209

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.