Literature DB >> 31765231

Modified Arthroscopic Latarjet Procedure: Suture-Button Fixation Achieves Excellent Remodeling at 3-Year Follow-up.

Jian Xu1, Haifeng Liu1, Wei Lu1, Zhenhan Deng1, Weimin Zhu1, Liangquan Peng1, Kan Ouyang1, Hao Li1, Daping Wang1.   

Abstract

BACKGROUND: Some studies have advocated the use of suture-button fixation during the Latarjet procedure to reduce complications associated with screw fixation. However, the sample size of these studies is relatively small, and their follow-up period is short.
PURPOSE: To investigate the efficacy of the suture-button Latarjet procedure with at least 3 years of follow-up and remodeling of the coracoid graft. STUDY
DESIGN: Case series; Level of evidence, 4.
METHODS: A total of 152 patients who underwent the suture-button Latarjet procedure between February 2013 and February 2016 were selected, and 128 patients who met the inclusion criteria were enrolled in this study. Preoperative and postoperative clinical results were assessed. The position and healing condition of the coracoid graft and arthropathy of the glenoid and humeral head were also assessed using radiography and 3-dimensional computed tomography (CT).
RESULTS: The mean follow-up time was 40.3 ± 5.8 months. There were 102 patients included in this study. The mean visual analog scale score for pain during motion, the American Shoulder and Elbow Surgeons score, the Rowe score, and the Walch-Duplay score were improved considerably. A total of 100 grafts achieved bone union. The overall absorption rate was 12.6% ± 4.3%. Graft absorption mostly occurred on the edge and outside the "best-fit" circle of the glenoid. A vertical position was achieved in 98 grafts (96% of all cases) immediately postoperatively, with the mean graft midline center at the 4 o'clock position. In the axial view, CT showed that 89 grafts were flush to the glenoid, whereas 2 and 11 grafts were fixed medially and laterally, respectively. In all cases, the bone graft and glenoid tended to extend toward each other to form concentric circles during the remodeling process. During follow-up observations, the height of the 11 grafts that were positioned laterally (ie, above the glenoid level) exhibited a wave-curved change. No arthropathy was observed in any patient.
CONCLUSION: Patient outcomes were satisfactory after the modified arthroscopic suture-button Latarjet technique. Graft absorption mostly occurred on the edge and outside the "best-fit" circle of the glenoid. The graft exhibited the phenomenon of ectatic growing when it fused with the glenoid and finally remodeled to a new concentric circle with the humeral head analogous to the original glenoid. Grafts positioned laterally did not cause arthropathy of the joints within the period of the study.

Entities:  

Keywords:  Latarjet; anterior instability; glenoid defect; outcome; remodeling; shoulder; suture button

Mesh:

Year:  2019        PMID: 31765231     DOI: 10.1177/0363546519887959

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  12 in total

Review 1.  A review of bone grafting techniques for glenoid reconstruction.

Authors:  Jeffrey A Zhang; Patrick H Lam; Julia Beretov; George Ac Murrell
Journal:  Shoulder Elbow       Date:  2021-04-17

2.  [An arthroscopic "inlay" Bristow procedure with suture button fixation: Surgical technique and radiology evaluation].

Authors:  Z X Shao; Q F Song; Y Q Zhao; G Q Cui
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2021-10-18

3.  [Radiographic study of effect of lateral placement of bone graft on shoulder joint degeneration after modified arthroscopic Latarjet surgery with elastic fixation].

Authors:  Qihuang Qin; Xinzhi Liang; Daqiang Liang; Zhenhan Deng; Zhihe Qiu; Sheng Li; Bing Wu; Ying Li; Hao Li; Haifeng Liu; Wei Lu
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2021-04-15

4.  Modification of the Traditional Open Latarjet Technique with the Use of Sutures and Cortical Buttons Instead of Screws.

Authors:  Dimitrios Kotzamitelos; Socrates Kalogrianitis
Journal:  Indian J Orthop       Date:  2021-02-06       Impact factor: 1.251

5.  Clinical and radiographic outcomes after Latarjet using suture-button fixation.

Authors:  Brandon J Erickson; Yousef Shishani; Stacy Jones; Anthony A Romeo; Reuben Gobezie
Journal:  JSES Int       Date:  2020-12-07

6.  Effect of Modified Arthroscopic Latarjet on Acromiohumeral Distance at 5-Year Follow-up.

Authors:  Daqiang Liang; Haifeng Liu; Xinzhi Liang; Qihuang Qin; Lujue Long; Yong Huang; Wei Lu; Zhenhan Deng
Journal:  Orthop J Sports Med       Date:  2021-12-20

7.  Arthroscopic "Double-Inlay" Eden-Hybinette Procedure with Modified Suture Button Fixation for the Revision of Failed Bristow-Latarjet.

Authors:  Zhenxing Shao; Xu Cheng; Hao Luo; Guoqing Cui
Journal:  Arthrosc Tech       Date:  2021-11-02

8.  Arthroscopic Iliac Crest Bone Graft Augmentation Using All-Suture Anchors for Shoulder Instability Caused by Glenoid Bone Loss.

Authors:  Tony Antonios; Magnus Arnander; Eyiyemi Pearse; Thomas Duncan Tennent
Journal:  Arthrosc Tech       Date:  2021-11-16

Review 9.  Traditional versus congruent-arc Latarjet anatomic and biomechanical perspective.

Authors:  Luciano A Rossi; Ignacio Tanoira; Franco Luis De Cicco; Maximiliano Ranalletta
Journal:  EFORT Open Rev       Date:  2021-04-01

10.  Arthroscopic iliac crest bone grafting in recurrent anterior shoulder instability: minimum 5-year clinical and radiologic follow-up.

Authors:  Elisabeth Boehm; Marvin Minkus; Philipp Moroder; Markus Scheibel
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2020-04-13       Impact factor: 4.342

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.