Literature DB >> 31760820

Avoidance of Vagal Response During Circumferential Pulmonary Vein Isolation: Effect of Initiating Isolation From Right Anterior Ganglionated Plexi.

Feng Hu1, Lihui Zheng1, Shangyu Liu1, Lishui Shen1, Erpeng Liang1, Ligang Ding1, Lingmin Wu1, Gang Chen1, Xiaohan Fan1, Yan Yao1.   

Abstract

BACKGROUND: Circumferential pulmonary vein isolation (CPVI) often cause unavoidable vagal reflexes during procedure due to the coincidental modification of ganglionated plexus which are located on pulmonary vein (PV) antrum. The right anterior ganglionated plexi (RAGP) which located at superoanterior area of right superior PV antrum is an essential station to regulate the cardiac autonomic nerve activities and is easily coincidentally ablated during CPVI. The aim of this study is to assess the effect of RAGP ablation on vagal response (VR) during CPVI.
METHODS: A total of 80 patients with paroxysmal atrial fibrillation who underwent the first time CPVI were prospectively enrolled and randomly assigned to 2 groups: group A (n=40), CPVI started with right PVs at RAGP site; group B (n=40): CPVI started with left PVs first, and the last ablation site is RAGP. Electrophysiological parameters include basal cycle length, A-H interval, H-V interval, sinus node recovery time, and atrioventricular node Wenckebach point were recorded before and after CPVI procedure.
RESULTS: During CPVI, the positive VR were only observed on 1 patient in group A and 25 patients in group B (P<0.001). A total of 21 patients with positive VR in group B needed for temporary ventricular pacing during procedure, while the only patient with positive VR in group A did not need for temporary ventricular pacing (P<0.001). Compared with baseline, basal cycle length, sinus node recovery time, and atrioventricular node Wenckebach point were decreased significantly after CPVI procedure in both groups (all P<0.05) and without differences between 2 groups.
CONCLUSIONS: Circumferential PV isolation initiated from RAGP could effectively inhibit VR occurrence and significantly increase heart rate during procedure.

Entities:  

Keywords:  atrial fibrillation; atrioventricular block; atrioventricular node; heart rate; pulmonary vein

Mesh:

Year:  2019        PMID: 31760820     DOI: 10.1161/CIRCEP.119.007811

Source DB:  PubMed          Journal:  Circ Arrhythm Electrophysiol        ISSN: 1941-3084


  2 in total

1.  Procedural Characteristics, Safety, and Follow-up of Modified Right-Sided Approach for Cardioneuroablation.

Authors:  Başar Candemir; Emir Baskovski; Osman Beton; Nur Shanableh; İrem Müge Akbulut; Volkan Kozluca; Kerim Esenboğa; Türkan Seda Tan; Timuçin Altın; Eralp Tutar
Journal:  Anatol J Cardiol       Date:  2022-08       Impact factor: 1.475

2.  Impact of atrial fibrillation ablation on long-term outcomes in patients with tachycardia-bradycardia syndrome.

Authors:  Shohei Kataoka; Koichiro Ejima; Kyoichiro Yazaki; Miwa Kanai; Daigo Yagishita; Morio Shoda; Nobuhisa Hagiwara
Journal:  J Arrhythm       Date:  2022-05-19
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.