| Literature DB >> 31757018 |
Jiasheng Li1, Jianying Yu1, Jun Xie1, Qunshan Ye2.
Abstract
With the increase of heavy traffic transportation, it is meaningful to study the performance change of pavements under heavy loads. To study the development of asphalt mixture under heavy load, an AC-13 asphalt mixture was prepared and a large-sized specimen wheel tracking test was conducted. Samples from different periods were extracted to research the influence of the cumulative load times under heavy load on asphalt mixtures. It was found that there were different variation rules on the performance of the asphalt mixture under different load conditions. The failure time on skid resistance was predicted by the fitting curve. Heavy load conditions would greatly speed up the failure of skid resistance. According to the sieving results, the stable gradation of 10-16 mm, 5-10 mm, 3-5 mm, and 0-3 mm after heavy load grinding was 10%, 37%, 23%, and 30%. It was found that the content of 10-16 mm had a significant correlation with the permanent deformation of the asphalt mixture, while there were no significant correlation between aggregate and skid resistance.Entities:
Keywords: aggregate sieving; asphalt mixture; heavy load; permanent deformation; skid resistance
Year: 2019 PMID: 31757018 PMCID: PMC6926924 DOI: 10.3390/ma12233814
Source DB: PubMed Journal: Materials (Basel) ISSN: 1996-1944 Impact factor: 3.623
Figure 1AC-13 gradation curve.
Physical properties of the SBS asphalt binder.
| Test Items | Results | Requirements | |
|---|---|---|---|
| Penetration 25 °C, 100 g, 5s (0.1 mm) | 76.2 | 60~80 | |
| Softening point (°C) | 63.6 | ≥60 | |
| Ductility 5 cm/min, 5 °C (cm) | 51.2 | ≥30 | |
| Density 15 °C (g/cm3) | 1.031 | / | |
| Solubility (TCE) (%) | 99.8 | ≥99 | |
| Aging 163 °C, 5 h | Mass change (%) | 0.4 | ±1.0 |
| Penetration ratio 25 °C (%) | 83.3 | ≥60 | |
| Residual ductility 5 °C (cm) | 32.3 | ≥20 | |
Figure 2Multifunctional pavement material tester and its internal structure.
Figure 3Specimen size and the core drilling.
Heavy load testing program for the AC-13 basalt asphalt mixture.
| Series | Load/MPa | Specimen Label | Duration/h | Cumulative Cycles |
|---|---|---|---|---|
| A | 0.7 | AC-13-0.7-1 | 12 | 8640 |
| AC-13-0.7-2 | 36 | 25,920 | ||
| AC-13-0.7-3 | 60 | 43,200 | ||
| AC-13-0.7-4 | 84 | 60,480 | ||
| AC-13-0.7-5 | 108 | 77,760 | ||
| B | 0.9 | AC-13-0.9-1 | 12 | 8640 |
| AC-13-0.9-2 | 36 | 25,920 | ||
| AC-13-0.9-3 | 60 | 43,200 | ||
| AC-13-0.9-4 | 84 | 60,480 | ||
| AC-13-0.9-5 | 108 | 77,760 | ||
| C | 1.1 | AC-13-1.1-1 | 12 | 8640 |
| AC-13-1.1-2 | 36 | 25,920 | ||
| AC-13-1.1-3 | 60 | 43,200 | ||
| AC-13-1.1-4 | 84 | 60,480 | ||
| AC-13-1.1-5 | 108 | 77,760 | ||
| D | 1.4 | AC-13-1.4-1 | 12 | 8640 |
| AC-13-1.4-2 | 36 | 25,920 | ||
| AC-13-1.4-3 | 60 | 43,200 | ||
| AC-13-1.4-4 | 84 | 60,480 | ||
| AC-13-1.4-5 | 108 | 77,760 |
Figure 4Heavy load effect on permanent deformation.
Figure 5Broken part in the cross-section view of the samples.
Figure 6Heavy load effect on the British pendulum number.
Figure 7Heavy load effect on TD.
Sieving result of ground asphalt mixture.
| Specimen Label | 10–16 mm | 5–10 mm | 3–5 mm | 0–3 mm and Filler |
|---|---|---|---|---|
| AC-13 | 28% | 28% | 14% | 30% |
| AC-13-0.7-1 | 24.18% | 30.95% | 16.11% | 28.75% |
| AC-13-0.7-2 | 22.16% | 30.51% | 17.57% | 29.76% |
| AC-13-0.7-3 | 21.42% | 31.65% | 17.95% | 28.98% |
| AC-13-0.7-4 | 20.09% | 32.86% | 17.71% | 29.34% |
| AC-13-0.7-5 | 15.82% | 34.80% | 19.67% | 29.71% |
| AC-13-0.9-1 | 22.80% | 31.57% | 17.46% | 28.17% |
| AC-13-0.9-2 | 21.77% | 31.46% | 17.32% | 29.45% |
| AC-13-0.9-3 | 20.86% | 32.34% | 18.16% | 28.64% |
| AC-13-0.9-4 | 18.82% | 33.48% | 18.76% | 28.94% |
| AC-13-0.9-5 | 14.66% | 35.46% | 20.45% | 29.43% |
| AC-13-1.1-1 | 20.68% | 32.26% | 18.75% | 28.31% |
| AC-13-1.1-2 | 20.28% | 33.38% | 18.51% | 27.83% |
| AC-13-1.1-3 | 16.97% | 34.27% | 20.73% | 28.03% |
| AC-13-1.1-4 | 13.29% | 35.30% | 22.63% | 28.78% |
| AC-13-1.1-5 | 10.05% | 37.76% | 23.53% | 28.65% |
| AC-13-1.4-1 | 19.38% | 33.34% | 19.51% | 27.77% |
| AC-13-1.4-2 | 17.62% | 33.65% | 19.85% | 28.89% |
| AC-13-1.4-3 | 15.01% | 34.26% | 22.87% | 27.86% |
| AC-13-1.4-4 | 12.61% | 36.22% | 23.02% | 28.16% |
| AC-13-1.4-5 | 10.17% | 36.40% | 23.37% | 30.06% |
Figure 8Gradation change in the ground mixture. (A) The loss in 10–16 mm, (B) the rise in 5–10 mm, (C) the rise in 3–5 mm.
Figure 9Gradation curve after heavy load.
Correlation between gradation and mixture performance.
| Load/MPa | Aggregate/mm | Permanent Deformation | BPN | TD | |||
|---|---|---|---|---|---|---|---|
| PCC | Sig. | PCC | Sig. | PCC | Sig. | ||
| 0.70 | 10–16 | 0.972 | 0.006 | −0.934 | 0.200 | −0.857 | 0.063 |
| 5–10 | 0.938 | 0.018 | −0.883 | 0.047 | −0.762 | 0.134 | |
| 3–5 | 0.923 | 0.025 | −0.906 | 0.034 | −0.877 | 0.051 | |
| 0.90 | 10–16 | 0.972 | 0.006 | −0.889 | 0.044 | −0.826 | 0.085 |
| 5–10 | 0.957 | 0.011 | −0.868 | 0.056 | −0.794 | 0.109 | |
| 3–5 | 0.950 | 0.013 | −0.861 | 0.061 | −0.783 | 0.117 | |
| 1.10 | 10–16 | 0.926 | 0.024 | −0.929 | 0.023 | −0.896 | 0.040 |
| 5–10 | 0.882 | 0.048 | −0.928 | 0.023 | −0.892 | 0.042 | |
| 3–5 | 0.948 | 0.014 | −0.922 | 0.026 | −0.897 | 0.039 | |
| 1.40 | 10–16 | 0.950 | 0.013 | −0.969 | 0.007 | −0.916 | 0.029 |
| 5–10 | 0.882 | 0.048 | −0.912 | 0.031 | −0.845 | 0.072 | |
| 3–5 | 0.957 | 0.011 | −0.927 | 0.023 | −0.901 | 0.037 | |