| Literature DB >> 31752440 |
Muhammad Umair1, Saqib Jabbar2, Ahmed M Senan1, Tayyaba Sultana3, Mustapha M Nasiru1, Assar A Shah4, Hong Zhuang5, Zhang Jianhao1.
Abstract
Influence of the combined effect of ultra-sonication (US) and high-voltage cold plasma treatment (HVCP) on the quality parameters of fresh carrot juice has been studied. During the treatment of ultra-sonication, carrot juice was subjected to a 0.5 inch probe for 3 min by adjusting the pulse duration 5 s on and off at 20 kHz frequency, amplitude level 80%. The ultrasound intensity was measured by using a thermocouple and was 46 Wcm-2. The temperature was maintained at 10 °C by an automatic control unit. During the treatment of HVCP, carrot juice was then subjected to dielectric barrier discharge (DBD) plasma discharge at 70 kV voltage for 4 min. Significant increases were observed when HVCP treated carrot juice was tested against total carotenoids, lycopene, and lutein when compared to the control treatments. Moreover, this increase was raised to its highest in all pigments, chlorogenic acid, sugar contents, and mineral profile, as the results of ultra-sonication when combined with high voltage atmospheric cold plasma (US-HVCP). Whereas, a significant decreased was observed in Mg, total plate count, yeast, and mold after US-HVCP treatment. Furthermore, results indicated that the combined effect of US-HVCP treatment has improved the quality and led to a higher concentration of lycopene, lutein, chlorogenic acid, and mineral compounds (Na, K, and P). Therefore, the findings of the current study suggested that US-HVCP treatment is a novel combined technique that could provide better quality and more stability during the processing of carrot juice with better physicochemical properties and bio-available nutrients, so this novel processing technique could serve as an alternative to traditional processes.Entities:
Keywords: combined effect; dielectric barrier discharge; high voltage atmospheric cold plasma; quality parameters; ultra-sonication
Year: 2019 PMID: 31752440 PMCID: PMC6915544 DOI: 10.3390/foods8110593
Source DB: PubMed Journal: Foods ISSN: 2304-8158
Figure 1Schematic diagram of the ultra-sonication in combination with high voltage cold plasma (US-HVCP) treatment of carrot juice.
Conditions of plasma-optical emission spectrometer.
| S. No | Working Conditions | Flow Rate/Units |
|---|---|---|
| 1 | Elements (Na, P, K and Mg) | 589.5, 213.6, 766.5 and 285.2 |
| 2 | Nebulized gas discharge | 0.85 L/Min |
| 3 | Plasma gas discharge | 16.5 L/Min |
| 4 | Auxiliary gas discharge | 0.21 L/Min |
| 5 | Plasma gas discharge | 15 L/Min |
| 6 | Sample flow rate | 1.8 mL/Min |
| 7 | Operating power | 1450 W |
| 8 | View Axial | Interface shear gas |
| 9 | Sample uptake rate | 1.25 mL/min |
| 10 | Spray chamber | cyclonic |
| 11 | Nebulizer type | Meinhard |
| 12 | Nebulizer set up | Instant |
| 13 | Replicates | 3 times |
Combined effect of treatments on different quality parameters.
| S. No | Treatment | Chlorogenic Acid µg/mL | Total Carotenoids µg/mL | Lycopene Contents µg/mL | Lutein Contents µg/mL |
|---|---|---|---|---|---|
| 1 | Control | 22.30 ± 0.09 c | 8.22 ± 0.02 d | 0.52 ± 0.01 d | 1.22 ± 0.06 d |
| 2 | HVCP | 25.67 ± 0.08 b | 10.81 ± 0.03 b | 1.71 ± 0.09 b | 1.65 ± 0.05 b |
| 3 | US | 23.16 ± 0.02 b,c | 10.03 ± 0.08 b | 1.83 ± 0.05 c | 1.56 ± 0.09 c |
| 4 | US-HVCP | 27.31 ± 0.06 a | 11.03 ± 0.05 a | 1.93 ± 0.04 a | 2.03 ± 0.02 a |
Values with different letters (a–d) in same column represent that they are significantly different from each other. HVCP: High voltage atmospheric cold plasma (HVCP), US: Ultrasonic treatment, US-HVCP: Ultrasonic treatment and high voltage atmospheric cold plasma.
Combined effect of blanching and HVCP on sugar content in carrot juice.
| S. No | Treatment | Sucrose g/L | Fructose g/L | Glucose g/L |
|---|---|---|---|---|
| 1 | Control | 41.04 ± 0.01 c | 18.65 ± 0.01 b | 20.52 ± 0.06 c |
| 2 | HVCP | 42.13 ± 0.03 b | 19.11 ± 0.02 a | 21.91 ± 0.02 a |
| 3 | US | 41.88 ± 0.06 b | 15.03 ± 0.03 b,c | 19.83 ± 0.04 c |
| 4 | US-HVCP | 42.36 ± 0.06 a | 16.03 ± 0.04 c | 21.23 ± 0.06 b |
Values with different letters (a–d) in same column represents that they are significantly different from each other. HVCP: High voltage atmospheric cold plasma (HVCP), US: Ultrasonic treatment, US-HVCP: Ultrasonic treatment and high voltage atmospheric cold plasma.
Figure 2Combined treatment effect of US and HVCP on the mineral profile of the carrot juice.
Combined treatment effect of HVCP and US on pH, °Brix, and color indexes.
| Treatment | pH | °Brix | Coloring-Index | Hue (h°) | C* | BI | ΔE | ||
|---|---|---|---|---|---|---|---|---|---|
| L* | A* | B* | |||||||
| Control | 7.77 ± 0.20 a | 6.08 ± 0.01 a | 35.31 ± 0.24 a | 19.53 ± 0.22 a | 29.66 ± 0.10 a | 13.02 ± 0.03 | 21.05 ± 0.01 | 6.01 ± 0.62 | 0.24 ± 0.01 |
| HVCP | 7.77 ± 0.20 a | 6.08 ± 0.02 a | 36.83 ± 0.22 a | 18.58 ± 0.23 a | 31.59 ± 0.11 a | 13.22 ± 0.01 | 21.44 ± 0.03 | 7.89 ± 0.33 | 0.32 ± 0.01 |
| US | 7.77 ± 0.21 a | 6.08 ± 0.01 a | 38.72 ± 0.34 a | 20.83 ± 0.21 a | 32.95 ± 0.88 a | 13.25 ± 0.02 | 21.76 ± 0.06 | 8.11 ± 0.79 | 0.49 ± 0.02 |
| US-HVCP | 7.77 ± 0.21 a | 6.08 ± 0.01 a | 36.05 ± 0.12 a | 18.23 ± 0.20 a | 30.01 ± 0.21 a | 13.11 ± 0.01 | 21.14 ± 0.02 | 6.56 ± 0.02 | 0.27 ± 0.01 |
Values with different letters (a–d) in same column represent that they are significantly different from each other. HVCP: High voltage atmospheric cold plasma (HVCP), US: Ultrasonic treatment, US-HVCP: Ultrasonic treatment and high voltage atmospheric cold plasma.
Figure 3Combined treatment effect of US and HVCP on the microbial activity of carrot juice.