Literature DB >> 31751958

Sensitive detection of cardiac troponin-I protein using fabricated piezoresistive microcantilevers by a novel method of asymmetric biofunctionalization.

Dilip Kumar Agarwal1, Arindam Kushagra, Mamta Ashwin, Ambika S Shukla, Vijay Palaparthy.   

Abstract

Microcantilever-based sensor platform has attracted a lot of attention over the time in detection of a variety of molecules due to their miniaturized dimensions. Sensitivity enhancement is an important aspect of such sensors, especially when used for point-of-care diagnostic purpose. However, the major concern while operating these sensors in deflection mode is their sensitivity which mainly relies on selective chemical modification protocols employed on these sensor surfaces. One of the ways of getting better sensitivity is through asymmetric (one side) biofunctionalization of the sensor surface. In the presented work here, we have demonstrated a novel approach of asymmetric biofunctionalization of proteins in overall sensitivity enhancement of piezoresistive silicon nitride-oxide microcantilever sensor platform inside a flow chamber. Herein, using our developed surface chemistry, asymmetrically biofunctionalized microcantilevers first exhibited a greater electrical response in terms of piezoresistance change than their symmetric counterpart in the detection of human immunoglobulins (HIgGs) protein. Finally, these microcantilevers were employed to exhibit the enhanced sensitivity towards the detection of a crucial cardiac marker protein, i.e. Troponin-I (cTnI) down to 250 ng ml-1 using asymmetric biofunctionalization process. This study shows that the developed asymmetric biofunctionalization methodology may be used as a general protocol to detect other important biomarkers of clinical applications with improved sensitivity.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31751958     DOI: 10.1088/1361-6528/ab5a18

Source DB:  PubMed          Journal:  Nanotechnology        ISSN: 0957-4484            Impact factor:   3.874


  1 in total

1.  Rapid and Sensitive Detection of Antigen from SARS-CoV-2 Variants of Concern by a Multivalent Minibinder-Functionalized Nanomechanical Sensor.

Authors:  Dilip Kumar Agarwal; Andrew C Hunt; Gajendra S Shekhawat; Lauren Carter; Sidney Chan; Kejia Wu; Longxing Cao; David Baker; Ramon Lorenzo-Redondo; Egon A Ozer; Lacy M Simons; Judd F Hultquist; Michael C Jewett; Vinayak P Dravid
Journal:  Anal Chem       Date:  2022-06-02       Impact factor: 8.008

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.