Utility Of Three-Dimensional Heads-Up Surgery In Cataract And Minimally Invasive Glaucoma Surgeries.

Hisato Ohno1.   

Abstract

PURPOSE: This study aimed to assess the utility of the three-dimensional (3D) heads-up visualization system for minimal incision cataract surgery (MICS) and minimally invasive glaucoma surgeries (MIGSs).
METHODS: Toric intraocular lens (IOL) implantation with phacoemulsification and trabecular microbypass stent implantation in patients with cataract and open-angle glaucoma were performed using the heads-up 3D visualization system combined with surgical navigation rather than the conventional microscope.
RESULTS: This procedure was found to have the following advantages: the ability to clearly observe the anterior chamber angle image without requiring frequent focus adjustment owing to the extended depth of field and emphasized stereoscopic effect provided by this system and maintain the surgeon's posture.
CONCLUSION: The feasibility and comfort of this system are greater than those of the conventional microscopic for performing MICS and MIGS.
© 2019 Ohno.

Entities:  

Keywords:  open-angle glaucoma; phacoemulsification; toric intraocular lens

Year:  2019        PMID: 31749604      PMCID: PMC6817768          DOI: 10.2147/OPTH.S227318

Source DB:  PubMed          Journal:  Clin Ophthalmol        ISSN: 1177-5467


Introduction

Recently, the method of conducting surgery using the three-dimensional (3D) heads-up visualization system, known as the heads-up surgery (HUS), has been widely accepted, especially for vitreoretinal procedures. Using digitally assisted image manipulation on the display, HUS can be comfortably performed even under conditions such as low-intensity light and extended depth of field at high magnification.1–3 In addition, multiple data, such as intraoperative optical coherence tomography and operative field view data, can be simultaneously observed on the display. Consequently, we determined that surgical navigation combined with a 3D heads-up display is the most practical tool for performing minimal incision cataract surgery (MICS) in clinical settings.4,5 Moreover, to ensure a good view of the trabecular meshwork in minimally invasive glaucoma surgery (MIGS),6,7 a gonioprism is used to inspect the angle. However, the surgeon must have certain experience and skill to achieve such a view. Based on this, we can consider that the extended depth of field at high magnification obtained in HUS is preferable for angle inspection using gonioprism. In this study, we reported the feasibility of HUS for MICS and MIGS.

Patients And Methods

Toric intraocular lens (IOL) implantations with phacoemulsification and trabecular microbypass stent implantation (iStent; Glaukos, CA, USA), which is an MIGS, using the NGENUITY 3D Visualization System with VERION Image Guided System (Alcon, Fort Worth, TX, USA) combined with the Leica Proveo 8 microscope (Leica Microsystems, Wetzlar, Germany) were performed for patients with cataract and open-angle glaucoma. This implantation was guided by VERION to achieve precise positioning (Figure 1). Furthermore, the Ocular Hill Surgical Gonioprism (Ocular Instruments Inc, Washington, USA) was used to implant iStent in a conventional manner, in which the microscope and patient’s face are tilted to achieve a good view of the anterior chamber angle. In addition, because the 3D display was placed in front of the surgeon, the surgeon’s posture was maintained throughout the procedure (Figure 2, ).
Figure 1

Toric IOL implantation by NGENUITY 3D Visualization System combined with VERION image guided system.

Figure 2

In HUS, the surgeon’s posture is maintained even if the microscope and patient’s face are tilted to acquire a good view of the anterior chamber angle when using a gonioprism.

Toric IOL implantation by NGENUITY 3D Visualization System combined with VERION image guided system. In HUS, the surgeon’s posture is maintained even if the microscope and patient’s face are tilted to acquire a good view of the anterior chamber angle when using a gonioprism. shows toric intraocular lens (IOL) implantations with phacoemulsification and trabecular microbypass stent implantation, using the NGENUITY 3D Visualization System with VERION Image Guided System for a patient with cataract and open-angle glaucoma. The surgeon’s posture is maintained during surgery.

Results

Compared with the conventional microscopic surgery, cataract surgery and trabecular microbypass stent implantations were compatible with HUS combined with Verion image guided system. Moreover, because of the extended depth of field at high magnification and emphasized stereoscopic effect provided by this technique, frequent focus adjustment is not required for trabecular microbypass stent implantation, unlike that required when using the conventional microscope.

Discussion

With HUS, it is possible to process the original image on the display exactly according to the surgeon’s requests without compromising image quality. There are several advantages of HUS such as lower intensity of light source, exaggeration of the structure and color of the image, overlay the images, and picture in picture (several images on the display simultaneously). So far, most reports of HUS are related to vitreoretinal surgery.1–3 However, with all these factors considered, the feasibility of this procedure is not only for vitreoretinal surgery but also for other kinds of ophthalmic surgeries. In this study, we report the feasibility of MICS and MIGS via 3D platforms that offer good visualization (less need for focusing and emphasized stereoscopic effect by larger display), good compatibility with Verion image guided system, and surgeon’s comfort. HUS was never inferior to the conventional microscopic surgery in MICS and MIGS. However, we believe that HUS might have the potential to change surgical microscopic observation system drastically. Further studies and innovation are required to develop the conventional microscopic observation system.
  7 in total

1.  Image-guided system versus manual marking for toric intraocular lens alignment in cataract surgery.

Authors:  Valentijn S C Webers; Noel J C Bauer; Nienke Visser; Tos T J M Berendschot; Frank J H M van den Biggelaar; Rudy M M A Nuijts
Journal:  J Cataract Refract Surg       Date:  2017-06       Impact factor: 3.351

2.  HEADS-UP SURGERY FOR VITREORETINAL PROCEDURES: An Experimental and Clinical Study.

Authors:  Claus Eckardt; Erica B Paulo
Journal:  Retina       Date:  2016-01       Impact factor: 4.256

3.  MINIMAL ENDOILLUMINATION LEVELS AND DISPLAY LUMINOUS EMITTANCE DURING THREE-DIMENSIONAL HEADS-UP VITREORETINAL SURGERY.

Authors:  Murtaza K Adam; Sarah Thornton; Carl D Regillo; Carl Park; Allen C Ho; Jason Hsu
Journal:  Retina       Date:  2017-09       Impact factor: 4.256

4.  Randomized evaluation of the trabecular micro-bypass stent with phacoemulsification in patients with glaucoma and cataract.

Authors:  Thomas W Samuelson; L Jay Katz; Jeffrey M Wells; Yi-Jing Duh; Jane Ellen Giamporcaro
Journal:  Ophthalmology       Date:  2010-09-15       Impact factor: 12.079

5.  Heads-up Cataract Surgery: Complication Rates, Surgical Duration, and Comparison With Traditional Microscopes.

Authors:  Robert J Weinstock; Vasilios F Diakonis; Adam J Schwartz; Alexander J Weinstock
Journal:  J Refract Surg       Date:  2019-05-01       Impact factor: 3.573

6.  Trabecular micro-bypass stent implantation during small-incision cataract surgery for open-angle glaucoma or ocular hypertension: Long-term results.

Authors:  Tobias H Neuhann
Journal:  J Cataract Refract Surg       Date:  2015-12       Impact factor: 3.351

7.  RESOLUTION, DEPTH OF FIELD, AND PHYSICIAN SATISFACTION DURING DIGITALLY ASSISTED VITREORETINAL SURGERY.

Authors:  William R Freeman; Kevin C Chen; Joseph Ho; Daniel L Chao; Henry A Ferreyra; A Burton Tripathi; Eric Nudleman; Dirk-Uwe Bartsch
Journal:  Retina       Date:  2019-09       Impact factor: 4.256

  7 in total
  5 in total

1.  Comparison of Three-Dimensional Surgical System Versus Binocular Microscope for Clear Corneal Incision in Cataract Surgery.

Authors:  Zehui Zhu; Pingjun Chang; Feng Huang; Songqing Shen; Xiaomeng Zhao; Xinpei Ji; Yun E Zhao
Journal:  Ophthalmol Ther       Date:  2022-06-24

2.  Initial experience with three-dimensional heads-up display system for cataract surgery - A comparative study.

Authors:  Jai A Kelkar; Aditya S Kelkar; Mounika Bolisetty
Journal:  Indian J Ophthalmol       Date:  2021-09       Impact factor: 1.848

3.  Facilitating Role of the 3D Viewing System in Tilted Microscope Positions for Cataract Surgery in Patients Unable to Lie Flat.

Authors:  Otman Sandali; Rachid Tahiri Joutei Hassani; Ashraf Armia Balamoun; Mohamed El Sanharawi; Vincent Borderie
Journal:  J Clin Med       Date:  2022-03-28       Impact factor: 4.241

4.  Three-dimensional heads-up surgery in ab-interno trabeculotomy: Image processing-assisted trabeculotomy.

Authors:  Takafumi Suzuki; Takashi Fujishiro; Koichiro Sugimoto; Makoto Aihara
Journal:  PLoS One       Date:  2022-02-10       Impact factor: 3.240

5.  Venturing into the third dimension of cataract surgery/observations with digital heads-up display - A personal take on NGENUITY for anterior segment surgeries.

Authors:  Prasanna Venkatesh Ramesh; Pranesh Balasubramaniam; Aji Kunnath Devadas; Prajnya Ray; Shruthy Vaishali Ramesh; Meena Kumari Ramesh; Ramesh Rajasekaran
Journal:  Indian J Ophthalmol       Date:  2022-02       Impact factor: 1.848

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.