Literature DB >> 31749460

Excitation and RF Field Control of a Human-Size 10.5-T MRI System.

Patrick Bluem1, Pierre-Francois Van de Moortele2, Gregor Adriany2, Zoya Popović3.   

Abstract

This paper presents an investigation of methods for improving homogeneity inside various dielectric phantoms situated in a 10.5 T human-sized MRI. The transmit B1 ( B 1 + ) field is excited with a quadrature fed circular patch-probe and a 12 element capacitively-loaded microstrip array. Both simulations and measurements show improved homogeneity in a cylindrical water phantom, an inhomogeneous phantom (pineapple), and a NIST standard phantom. The simulations are performed using a full-wave finite-difference time-domain solver (Sim4Life) in order to find the B 1 + field distribution and compared to the gradient recalled echo image and efficiency result. For additional field uniformity, the wall electromagnetic boundary conditions are modified with a passive quadrifilar helix. Finally, these methods are applied in simulation to head imaging of an anatomically correct human body model (Duke, IT'IS Virtual Population) showing improved homogeneity and specific absorption rate for various excitations.

Entities:  

Keywords:  Finite-difference time-domain (FDTD); Magnetic resonance imaging (MRI); Patch antenna; Waveguide

Year:  2018        PMID: 31749460      PMCID: PMC6867708          DOI: 10.1109/TMTT.2018.2884405

Source DB:  PubMed          Journal:  IEEE Trans Microw Theory Tech        ISSN: 0018-9480            Impact factor:   3.599


  16 in total

1.  Actual flip-angle imaging in the pulsed steady state: a method for rapid three-dimensional mapping of the transmitted radiofrequency field.

Authors:  Vasily L Yarnykh
Journal:  Magn Reson Med       Date:  2007-01       Impact factor: 4.668

2.  The fractionated dipole antenna: A new antenna for body imaging at 7 Tesla.

Authors:  Alexander J E Raaijmakers; Michel Italiaander; Ingmar J Voogt; Peter R Luijten; Johannes M Hoogduin; Dennis W J Klomp; Cornelis A T van den Berg
Journal:  Magn Reson Med       Date:  2015-05-02       Impact factor: 4.668

3.  Design of a parallel transmit head coil at 7T with magnetic wall distributed filters.

Authors:  Ian R O Connell; Kyle M Gilbert; Mohamed A Abou-Khousa; Ravi S Menon
Journal:  IEEE Trans Med Imaging       Date:  2014-11-13       Impact factor: 10.048

4.  Dynamically applied B1+ shimming solutions for non-contrast enhanced renal angiography at 7.0 Tesla.

Authors:  Gregory J Metzger; Edward J Auerbach; Can Akgun; Josh Simonson; Xiaoming Bi; Kâmil Uğurbil; Pierre-François van de Moortele
Journal:  Magn Reson Med       Date:  2012-03-22       Impact factor: 4.668

5.  Rat brain MRI at 16.4T using a capacitively tunable patch antenna in combination with a receive array.

Authors:  G Shajan; Jens Hoffmann; Dávid Z Balla; Dinesh K Deelchand; Klaus Scheffler; Rolf Pohmann
Journal:  NMR Biomed       Date:  2012-02-17       Impact factor: 4.044

6.  Human brain imaging at 9.4 T using a tunable patch antenna for transmission.

Authors:  Jens Hoffmann; G Shajan; Juliane Budde; Klaus Scheffler; Rolf Pohmann
Journal:  Magn Reson Med       Date:  2012-06-15       Impact factor: 4.668

7.  Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

Authors:  Bing Wu; Chunsheng Wang; Jonathan Lu; Yong Pang; Sarah J Nelson; Daniel B Vigneron; Xiaoliang Zhang
Journal:  IEEE Trans Med Imaging       Date:  2011-08-30       Impact factor: 10.048

8.  Travelling-wave nuclear magnetic resonance.

Authors:  David O Brunner; Nicola De Zanche; Jürg Fröhlich; Jan Paska; Klaas P Pruessmann
Journal:  Nature       Date:  2009-02-19       Impact factor: 49.962

9.  Shielded microstrip array for 7T human MR imaging.

Authors:  Bing Wu; Chunsheng Wang; Douglas A C Kelley; Duan Xu; Daniel B Vigneron; Sarah J Nelson; Xiaoliang Zhang
Journal:  IEEE Trans Med Imaging       Date:  2009-10-09       Impact factor: 10.048

10.  Initial in vivo rodent sodium and proton MR imaging at 21.1 T.

Authors:  Victor D Schepkin; William W Brey; Peter L Gor'kov; Samuel C Grant
Journal:  Magn Reson Imaging       Date:  2010-01-04       Impact factor: 2.546

View more
  1 in total

1.  Evaluation of 8-Channel Radiative Antenna Arrays for Human Head Imaging at 10.5 Tesla.

Authors:  Myung Kyun Woo; Lance DelaBarre; Matt Thomas Waks; Young Woo Park; Russell Luke Lagore; Steve Jungst; Yigitcan Eryaman; Se-Hong Oh; Kamil Ugurbil; Gregor Adriany
Journal:  Sensors (Basel)       Date:  2021-09-08       Impact factor: 3.576

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.