Literature DB >> 31748862

Transcatheter aortic valve replacement acutely improves left ventricular mechanical efficiency in severe aortic stenosis: effects of different phenotypes.

Paolo N Marino1, G Binda2,3, E Calzaducca2, A Panizza2, I Ferrari2, I Bellacosa2, G Ambrosio4,3.   

Abstract

AIM: Aortic stenosis is a frequent valvular disease, with transcatheter aortic valve implantation (TAVI) being performed when surgical replacement is at increased risk. However, TAVI-induced effects on myocardial efficiency are unknown. We aimed to investigate changes in LV mechano-energetic pre-/post-TAVI and their prognostic impact.
METHODS: A total of 46 patients (25 males) received transesophageal and simultaneous radial pressure plus transaortic gradient monitoring before/immediately after prosthesis deployment. Efficiency was computed as external work/potential energy, as derived from LV pressure-volume plots; myocardial oxygen consumption (MVO2) was estimated as PWImod, i.e. a noninvasively validated alternative for MVO2 estimation.
RESULTS: TAVI was successful in all patients, peak transaortic gradient decreasing - 40 ± 20 mmHg (p < 0.001). Efficiency improved post-TAVI (+ 0.6 ± 0.12; p = 0.004), with a concomitant PWImod reduction (- 16 ± 31%; p < 0.001). When contextualized to fixed PWImod value (5 ml/min/100 g), efficiency significantly affected survival (p = 0.029). Over 1026 ± 450-day follow-up, a change in efficiency pre-/post-TAVI ≤ 0.021 (median of the difference) predicted more deaths from any cause (30%) as compared with a change > 0.021 (17%), particularly in those patients with a pre-TAVI mean high-gradient (HG ≥ 40 mmHg) phenotype (p < 0.05). In particular, HG patients exhibited the lowest efficiency/PWImod ratio pre-/post-TAVI (p = 0.048), relative to the other aortic stenosis patients, suggestive of an unfavourable matching between cardiac function and metabolic demand, which foreshortens some intrinsic damaged muscle condition in these patients.
CONCLUSION: LV mechanical efficiency improves immediately post-TAVI, notwithstanding an inhomogeneous mechano-energetic matching among the aortic stenosis patients, which can impact negatively on their long-term prognosis, particularly in those with the HG phenotype.

Entities:  

Keywords:  Aortic stenosis phenotypes; Aortic valve stenosis; Myocardial efficiency; Oxygen consumption; Pressure–volume plot; Transcatheter aortic valve implantation

Mesh:

Year:  2019        PMID: 31748862     DOI: 10.1007/s00392-019-01570-3

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  1 in total

Review 1.  Kidney injury as post-interventional complication of TAVI.

Authors:  Michael Morcos; Christof Burgdorf; Andrijana Vukadinivikj; Felix Mahfoud; Joerg Latus; Pontus B Persson; Vedat Schwenger; Andrew Remppis
Journal:  Clin Res Cardiol       Date:  2020-08-25       Impact factor: 5.460

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.