Literature DB >> 3174831

Factors affecting Caltrac and Calcount accelerometer output.

J A Balogun1, L O Amusa, I U Onyewadume.   

Abstract

This investigation determined the effects of different trunk levels and walking speeds on the output of two physical activity monitoring devices--the Caltrac and the Calcount. Twenty healthy subjects walked on a level motor-driven treadmill at two walking speeds (2 and 4 mph) with the accelerometer affixed to different trunk locations (waist belt and chest line). After each five-minute exercise bout, the accelerometer readings (in arbitrary units) were recorded and expressed in counts per minute. The analysis of variance for the Calcount accelerometer data revealed a significant main effect for location and speed. The Caltrac accelerometer data revealed a significant F ratio for the speed main effect and the location x speed interaction effect. Overall, the accelerometer reading when worn at the waist belt was higher (p less than .05) than when affixed to the chest line. For both accelerometers, the output increased with increased walking speed. The correlation between the Caltrac and Calcount accelerometer readings ranged from -.09 to .49, indicating that the output of the two accelerometers cannot be compared directly.

Mesh:

Year:  1988        PMID: 3174831

Source DB:  PubMed          Journal:  Phys Ther        ISSN: 0031-9023


  4 in total

1.  Effects of placement and orientation of body-fixed accelerometers on the assessment of energy expenditure during walking.

Authors:  C V Bouten; A A Sauren; M Verduin; J D Janssen
Journal:  Med Biol Eng Comput       Date:  1997-01       Impact factor: 2.602

2.  Motion analysis of sun salutation using magnetometer and accelerometer.

Authors:  Sn Omkar; Meenakshi Mour; Debarun Das
Journal:  Int J Yoga       Date:  2009-07

Review 3.  A systematic literature review of reviews on techniques for physical activity measurement in adults: a DEDIPAC study.

Authors:  Kieran P Dowd; Robert Szeklicki; Marco Alessandro Minetto; Marie H Murphy; Angela Polito; Ezio Ghigo; Hidde van der Ploeg; Ulf Ekelund; Janusz Maciaszek; Rafal Stemplewski; Maciej Tomczak; Alan E Donnelly
Journal:  Int J Behav Nutr Phys Act       Date:  2018-02-08       Impact factor: 6.457

4.  Wearable Hand Module and Real-Time Tracking Algorithms for Measuring Finger Joint Angles of Different Hand Sizes with High Accuracy using FBG Strain Sensor.

Authors:  Jun Sik Kim; Byung Kook Kim; Minsu Jang; Kyumin Kang; Dae Eun Kim; Byeong-Kwon Ju; Jinseok Kim
Journal:  Sensors (Basel)       Date:  2020-03-30       Impact factor: 3.576

  4 in total