Literature DB >> 31745377

Interaction between noise suppression and inhomogeneity correction in MRI.

Albert Montillo1, Jayaram Udupa1, Leon Axel2, Dimitris Metaxas3.   

Abstract

While cardiovascular disease is the leading cause of death in most developed countries, SPAMM-MRI can reduce morbidity by facilitating patient diagnosis. An image analysis method with a high degree of automation is essential for clinical adoption of SPAMM-MRI. The degree of this automation is dependent on the amount of thermal noise and surface coil-induced intensity inhomogeneity that can be removed from the images. An ideal noise suppression algorithm removes thermal noise yet retains or enhances the strength of the edges of salient structures. In this paper, we quantitatively compare and rank several noise suppression algorithms in images from both normal and diseased subjects using measures of the residual noise and edge strength and the statistical significance levels and confidence intervals of these measures. We also investigate the interrelationship between inhomogeneity correction and noise suppression algorithms and compare the effect of the ordering of these algorithms. The variance of thermal noise does not tend to change with position; however, inhomogeneity correction increases noise variance in deep thoracic regions. We quantify the degree to which an inhomogeneity estimate can improve noise suppression and whether noise suppression can facilitate the identification of homogeneous tissue regions, and thereby, assist in inhomogeneity correction.

Entities:  

Keywords:  MRI; SPAMM; inhomogeneity correction; surface coil; thermal noise suppression

Year:  2003        PMID: 31745377      PMCID: PMC6863362          DOI: 10.1117/12.483555

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  6 in total

1.  On standardizing the MR image intensity scale.

Authors:  L G Nyúl; J K Udupa
Journal:  Magn Reson Med       Date:  1999-12       Impact factor: 4.668

2.  Scale-based diffusive image filtering preserving boundary sharpness and fine structures.

Authors:  P K Saha; J K Udupa
Journal:  IEEE Trans Med Imaging       Date:  2001-11       Impact factor: 10.048

3.  A nonparametric method for automatic correction of intensity nonuniformity in MRI data.

Authors:  J G Sled; A P Zijdenbos; A C Evans
Journal:  IEEE Trans Med Imaging       Date:  1998-02       Impact factor: 10.048

4.  Intensity correction in surface-coil MR imaging.

Authors:  L Axel; J Costantini; J Listerud
Journal:  AJR Am J Roentgenol       Date:  1987-02       Impact factor: 3.959

5.  Automated Segmentation of the Left and Right Ventricles in 4D Cardiac SPAMM Images.

Authors:  Albert Montillo; Dimitris Metaxas; Leon Axel
Journal:  Med Image Comput Comput Assist Interv       Date:  2002-10-10

6.  Surface coil MR imaging of the human brain with an analytic reception profile correction.

Authors:  S E Moyher; D B Vigneron; S J Nelson
Journal:  J Magn Reson Imaging       Date:  1995 Mar-Apr       Impact factor: 4.813

  6 in total
  1 in total

1.  Feasibility study on ultra-low dose 3D scout of organ based CT scan planning.

Authors:  Zhye Yin; Yangyang Yao; Albert Montillo; Peter M Edic; Bruno De Man
Journal:  Conf Proc Int Conf Image Form Xray Comput Tomogr       Date:  2014-06
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.