Literature DB >> 31743722

Aptamer-antibody dual probes on single-walled carbon nanotube bridged dielectrode: Comparative analysis on human blood clotting factor.

Jian Yao1, Shujing Li2, Liping Zhang3, Yuzhi Yang3, Subash C B Gopinath4, Thangavel Lakshmipriya5, Yawei Zhou6.   

Abstract

Haemophilia is a blood clotting disorder known as 'Christmas disease' caused when the blood has defect with the clotting factor(s). Bleeding leads various issues, such as chronic pain, arthritis and a serious complication during the surgery. Identifying this disease is mandatory to take the necessary treatment and maintains the normal clotting. It has been proved that the level of factor IX (FIX) is lesser with haemophilia patient and the attempt here is focused to quantify FIX level by interdigitated electrode (IDE) sensor. Single-walled carbon nanotube (SWCNT) was utilized to modify IDE sensing surface. On this surface, dual probing was evaluated with aptamer and antibody to bring the possible advantages. The detection limit with antibody was found to be 1 pM, while aptamer shows 100 fM. Further, a fine-tuning was attempted with sandwich pattern of aptamer-FIX-antibody and antibody-FIX-aptamer and compared. Specific elevation of detection with 10 folds was noticed and displayed the detection at 100 f. in both sandwich patterns. In addition, FIX was detected in the diluted human serum by aptamer-FIX-antibody sandwich, it was found that FIX detected from the dilution factor 1:640. A novel demonstration is with higher discrimination against other clotting factors, XI and VII.
Copyright © 2019 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptamer; Clotting factors; Haemophilia; Interdigitated sensor; Single-walled carbon nanotube

Mesh:

Substances:

Year:  2019        PMID: 31743722     DOI: 10.1016/j.ijbiomac.2019.10.156

Source DB:  PubMed          Journal:  Int J Biol Macromol        ISSN: 0141-8130            Impact factor:   6.953


  2 in total

1.  Current-Volt Biosensing "Cystatin C" on Carbon Nanowired Interdigitated Electrode Surface: A Clinical Marker Analysis for Bulged Aorta.

Authors:  Xi Chen; Jie Kang; Qiu Sun; Cheng Liu; Hongling Wang; Chen Wang; Subash C B Gopinath
Journal:  J Anal Methods Chem       Date:  2022-05-23       Impact factor: 2.594

Review 2.  Aptasensors versus immunosensors-Which will prevail?

Authors:  Sofia Arshavsky-Graham; Christopher Heuer; Xin Jiang; Ester Segal
Journal:  Eng Life Sci       Date:  2022-01-13       Impact factor: 2.678

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.