Rafael D Malgor1, Pablo Marques de Marino2, Eric Verhoeven2, Athanasios Katsargyris2. 1. Department of Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany; Division of Vascular Surgery and Endovascular Therapy, University of Colorado, Anschutz Medical Center, Aurora, Colo. Electronic address: rafael.malgor@ucdenver.edu. 2. Department of Vascular and Endovascular Surgery, Paracelsus Medical University, Nuremberg, Germany.
Abstract
OBJECTIVE: Upper extremity access (UEA) is an important component of complex fenestrated and branched endovascular aneurysm repair (F/BEVAR). Open and percutaneous UEA approaches have been reported during these procedures. The aim of this review was to assess the outcomes of UEA done to facilitate F/BEVAR. METHODS: A systematic review of studies focusing on upper extremity arterial access during F/BEVAR was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline. Three databases including PubMed MEDLINE, Embase, and Cochrane Library were queried. Outcomes of interest included UEA-related and other unrelated early and late morbidity and mortality, such as arterial occlusion, neurologic deficit, bleeding complications, and stroke, in patients undergoing UEA during F/BEVAR. RESULTS: Five full-text manuscripts and one abstract met criteria to be included, accounting for a total of 495 patients. The median age of patients who underwent UEA during F/BEVAR was 73.4 years. Predominantly male patients (371 [74.9%]) were treated. Indications for F/BEVAR were thoracoabdominal aortic aneurysms in 325 (65.6%), pararenal aneurysms in 96 (19.4%), juxtarenal aneurysms in 44 (8.9%), and suprarenal aortic aneurysms in 30 (6.1%). Axillary conduits were created in 29 (5.8%) patients. A total of 41 (8.2%) UEA-related complications were reported. Of those 41 complications, 17 (41.5%) were access bleeding, 10 (24.4%) were ischemic strokes, 7 (17.1%) were arterial occlusions, 4 (9.7%) were upper extremity neurologic deficits, 2 (4.9%) were arterial stenoses, and 1 (2.4%) was pseudoaneurysm. UEA-related complications were reported in 15 of 56 (26.8%) patients undergoing percutaneous UEA and 26 of 439 (5.9%) undergoing open UEA (P < .001). CONCLUSIONS: The overall complication rate associated with UEA during F/BEVAR is low, with 2% stroke rate reported. The percutaneous approach showed a higher UEA-related complication rate compared with open UEA. More studies on percutaneous UEA and randomized studies comparing open vs percutaneous UEA during F/BEVAR are warranted to determine the safest and most efficient UEA approach strategy during complex aortic procedures.
OBJECTIVE: Upper extremity access (UEA) is an important component of complex fenestrated and branched endovascular aneurysm repair (F/BEVAR). Open and percutaneous UEA approaches have been reported during these procedures. The aim of this review was to assess the outcomes of UEA done to facilitate F/BEVAR. METHODS: A systematic review of studies focusing on upper extremity arterial access during F/BEVAR was performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline. Three databases including PubMed MEDLINE, Embase, and Cochrane Library were queried. Outcomes of interest included UEA-related and other unrelated early and late morbidity and mortality, such as arterial occlusion, neurologic deficit, bleeding complications, and stroke, in patients undergoing UEA during F/BEVAR. RESULTS: Five full-text manuscripts and one abstract met criteria to be included, accounting for a total of 495 patients. The median age of patients who underwent UEA during F/BEVAR was 73.4 years. Predominantly male patients (371 [74.9%]) were treated. Indications for F/BEVAR were thoracoabdominal aortic aneurysms in 325 (65.6%), pararenal aneurysms in 96 (19.4%), juxtarenal aneurysms in 44 (8.9%), and suprarenal aortic aneurysms in 30 (6.1%). Axillary conduits were created in 29 (5.8%) patients. A total of 41 (8.2%) UEA-related complications were reported. Of those 41 complications, 17 (41.5%) were access bleeding, 10 (24.4%) were ischemic strokes, 7 (17.1%) were arterial occlusions, 4 (9.7%) were upper extremity neurologic deficits, 2 (4.9%) were arterial stenoses, and 1 (2.4%) was pseudoaneurysm. UEA-related complications were reported in 15 of 56 (26.8%) patients undergoing percutaneous UEA and 26 of 439 (5.9%) undergoing open UEA (P < .001). CONCLUSIONS: The overall complication rate associated with UEA during F/BEVAR is low, with 2% stroke rate reported. The percutaneous approach showed a higher UEA-related complication rate compared with open UEA. More studies on percutaneous UEA and randomized studies comparing open vs percutaneous UEA during F/BEVAR are warranted to determine the safest and most efficient UEA approach strategy during complex aortic procedures.
Authors: Carla K Scott; Anna L Driessen; Marilisa Soto Gonzalez; Fatemeh Malekpour; Gerardo G Guardiola; Mirza S Baig; Melissa L Kirkwood; Carlos H Timaran Journal: J Vasc Surg Date: 2021-09-28 Impact factor: 4.860
Authors: Sven R Hauck; Wolf Eilenberg; Alexander Kupferthaler; Maximilian Kern; Theresa-Marie Dachs; Alexander Wressnegger; Christoph Neumayer; Christian Loewe; Martin A Funovics Journal: Cardiovasc Intervent Radiol Date: 2022-04-07 Impact factor: 2.797