| Literature DB >> 31740155 |
Dominick Shelton1, Gerhard Dashi1, Mark Cheung1, Thao Sindall1.
Abstract
BACKGROUND: Methemoglobinemia and carbon monoxide poisoning are potentially life-threatening conditions that can present with nonspecific clinical features. This lack of specificity increases the probability of misdiagnosis or avoidable delays in diagnosis and management. These conditions are both treatable with antidotes of methylene blue and oxygen, respectively. Modern blood gas analyzers have the ability to measure carboxyhemoglobin (COHb) and methemoglobin (MetHb) levels without any additional resources. However, these results, although readily available from the machine used to perform the analysis, are not fully reported by some hospital clinical laboratories. CASE REPORT: A 49-year-old male presented with shortness of breath and cyanosis after inhaling cocaine via a nasal route ("snorting"). Methemoglobinemia was not initially considered in the differential diagnosis. However, the diagnosis of methemoglobinemia was made once newly routinely reported laboratory results revealed an elevated MetHb level. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Routinely reporting MetHb and COHb levels with arterial and venous blood gas results will facilitate making the diagnoses of these infrequently diagnosed causes of hypoxia more quickly so that early treatment of these uncommon but potentially lethal conditions can be initiated promptly.Entities:
Keywords: blood gas analysis; carboxyhemoglobin; emergency medicine; methemoglobin
Mesh:
Substances:
Year: 2019 PMID: 31740155 DOI: 10.1016/j.jemermed.2019.09.024
Source DB: PubMed Journal: J Emerg Med ISSN: 0736-4679 Impact factor: 1.484