Three-dimensional printing technologies in the fabrication of maxillofacial prosthesis: A case report.

Pinar Cevik1, Mustafa Kocacikli1.   

Abstract

PURPOSE: Patients with maxillofacial deformities always seek for aesthetic prosthesis. Recently, three-dimensional printing technologies have been used for dental treatments on such patients. CASE REPORT: A 24-year-old man reported to the Department of Prosthodontics for replacement of his missing right ear induced by a trauma. A magnet-retained auricular prosthesis was planned for the patient. Three-dimensional scanning was performed on the healthy side by using a three-dimensional optical scanner and the data were mirrored. The mirrored image was then imported to a software and a virtual model of the future prosthesis was obtained for the defect side. A three-dimensional printer was used to fabricate a negative mold for the mirrored image by using additive manufacturing. Initially, an impression of the defect side was made; then, the cast model was obtained in a dental flask. Magnets of the prosthesis were inserted to the acrylic resin framework on the cast model. Room temperature vulcanized silicone elastomer was mixed and poured into the three-dimensionally fabricated mold. Then, the flask was placed over the negative mold firmly. After polymerization of the silicone, the auricular prosthesis was delivered to the patient and the patient was instructed to clean the prosthesis daily.
CONCLUSIONS: Three-dimensional printing technology was used for the fabrication of the patient's missing ear. This method eliminated the conventional laboratory steps and reduced the number of stages of the fabrication of a silicone prosthesis. The negative mold of the defect side allowed us a direct fabrication of the silicone prosthesis without a need for waxing or flasking procedures.

Entities:  

Keywords:  Three-dimensional printing; auricular prosthesis; silicone elastomers

Mesh:

Substances:

Year:  2019        PMID: 31739725     DOI: 10.1177/0391398819887401

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  2 in total

1.  Application Value of the CT Scan 3D Reconstruction Technique in Maxillofacial Fracture Patients.

Authors:  Jie Kang; Lijie Jiang
Journal:  Evid Based Complement Alternat Med       Date:  2022-07-07       Impact factor: 2.650

Review 2.  The Effect of Zirconium Dioxide (ZrO2) Nanoparticles Addition on the Mechanical Parameters of Polymethyl Methacrylate (PMMA): A Systematic Review and Meta-Analysis of Experimental Studies.

Authors:  Kamila Chęcińska; Maciej Chęciński; Maciej Sikora; Zuzanna Nowak; Sławomir Karwan; Dariusz Chlubek
Journal:  Polymers (Basel)       Date:  2022-03-06       Impact factor: 4.329

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.