Literature DB >> 31728313

Motion correction of chemical exchange saturation transfer MRI series using robust principal component analysis (RPCA) and PCA.

Chongxue Bie1, Yuhua Liang1, Lihong Zhang1, Yingcheng Zhao1, Yanrong Chen1, Xueru Zhang1, Xiaowei He1, Xiaolei Song1.   

Abstract

BACKGROUND: Chemical exchange saturation transfer (CEST) MRI requires the acquisition of multiple saturation-weighted images and can last several minutes. Misalignments among these images, which are often due to the inevitable motion of the subject, will corrupt CEST contrast maps and result in large quantification errors. Therefore, the registration of the CEST series is critical. However, registration is challenging since common intensity-based registration algorithms may fail to differentiate CEST signals from motion artifacts. Herein, we studied how different patterns of motion affect CEST quantification and proposed a cascaded two-step registration scheme by utilizing features extracted from the entire Z-spectral image series instead of direct registration to a single image.
METHODS: The proposed approach is conducted in two stages: during the first coarse registration, the Z-spectral image series is decomposed by robust principal component analysis (RPCA) to separate CEST contrast from motion. The recomposed image series using only the low-rank component, which contains minimized motion, are averaged to generate a reference for the alignment of the image series. To further remove residual misalignments, the coarse registration is followed by a refinement stage, which uses PCA iteratively to generate motionless synthetic reference series with the first few principal components (PCs) that correspond to CEST contrast. In the end, the quality check is performed to exclude the images with unsuccessful registration.
RESULTS: The proposed registration scheme (RPCA + PCA_R) was assessed by both phantom experiments and in vivo data of tumor-bearing mouse brain, with simulated random rigid motion in different patterns applied to the acquired static Z-spectral image series. For comparison, previous correction schemes using an explicit image [either S0 or Ssat(∆ω)] as registration reference were also performed, named as S0_R and Ssat_R respectively. To illustrate the advantage of combination of RPCA and PCA, registration was also exploited using either only the RPCA-based method (RPCA_R) or only the PCA-based one (PCA_R). Compared with the above four methods, RPCA + PCA_R allowed for more accurate correction of the corrupted Z-spectral images, exhibiting smaller MTRasym(∆ω) error maps and lower residual Z-spectra referring to the static data. Among all the five correction methods, the corrected Z-spectral image series by RPCA + PCA_R and the resulting MTRasym(∆ω) maps achieved the highest correlation coefficients (CC) with respect to the static ones.
CONCLUSIONS: The registration scheme of RPCA + PCA_R provides robust motion correction between two specific Z-spectral images and among an entire image series, through extraction of the static component from the entire Z-spectra set and inclusion of a PCA-based refinement step. Therefore, this method can help improve CEST acquisition and quantification. 2019 Quantitative Imaging in Medicine and Surgery. All rights reserved.

Entities:  

Keywords:  Chemical exchange saturation transfer (CEST); motion correction; principal component analysis (PCA); robust principal component analysis (RPCA)

Year:  2019        PMID: 31728313      PMCID: PMC6828584          DOI: 10.21037/qims.2019.09.14

Source DB:  PubMed          Journal:  Quant Imaging Med Surg        ISSN: 2223-4306


  45 in total

1.  MRI thermometry based on PARACEST agents.

Authors:  Shanrong Zhang; Craig R Malloy; A Dean Sherry
Journal:  J Am Chem Soc       Date:  2005-12-21       Impact factor: 15.419

2.  Quantitative description of the asymmetry in magnetization transfer effects around the water resonance in the human brain.

Authors:  Jun Hua; Craig K Jones; Jaishri Blakeley; Seth A Smith; Peter C M van Zijl; Jinyuan Zhou
Journal:  Magn Reson Med       Date:  2007-10       Impact factor: 4.668

3.  Contributors to contrast between glioma and brain tissue in chemical exchange saturation transfer sensitive imaging at 3 Tesla.

Authors:  Rachel Scheidegger; Eric T Wong; David C Alsop
Journal:  Neuroimage       Date:  2014-05-20       Impact factor: 6.556

4.  Robust motion correction in CEST imaging exploiting low-rank approximation of the z-spectrum.

Authors:  Tobias Wech; Herbert Köstler
Journal:  Magn Reson Med       Date:  2018-04-15       Impact factor: 4.668

5.  Salicylic acid analogues as chemical exchange saturation transfer MRI contrast agents for the assessment of brain perfusion territory and blood-brain barrier opening after intra-arterial infusion.

Authors:  Xiaolei Song; Piotr Walczak; Xiaowei He; Xing Yang; Monica Pearl; Jeff W M Bulte; Martin G Pomper; Michael T McMahon; Mirosław Janowski
Journal:  J Cereb Blood Flow Metab       Date:  2016-03-15       Impact factor: 6.200

6.  Low-rank to the rescue - atlas-based analyses in the presence of pathologies.

Authors:  Xiaoxiao Liu; Marc Niethammer; Roland Kwitt; Matthew McCormick; Stephen Aylward
Journal:  Med Image Comput Comput Assist Interv       Date:  2014

7.  Assessment of ischemic penumbra in patients with hyperacute stroke using amide proton transfer (APT) chemical exchange saturation transfer (CEST) MRI.

Authors:  Anna Tietze; Jakob Blicher; Irene Klaerke Mikkelsen; Leif Østergaard; Megan K Strother; Seth A Smith; Manus J Donahue
Journal:  NMR Biomed       Date:  2013-11-28       Impact factor: 4.044

8.  Nonrigid registration of ultrasound and MRI using contextual conditioned mutual information.

Authors:  Hassan Rivaz; Zahra Karimaghaloo; Vladimir S Fonov; D Louis Collins
Journal:  IEEE Trans Med Imaging       Date:  2014-03       Impact factor: 10.048

9.  DNER, an epigenetically modulated gene, regulates glioblastoma-derived neurosphere cell differentiation and tumor propagation.

Authors:  Peng Sun; Shuli Xia; Bachchu Lal; Charles G Eberhart; Alfredo Quinones-Hinojosa; Jarek Maciaczyk; William Matsui; Francesco Dimeco; Sara M Piccirillo; Angelo L Vescovi; John Laterra
Journal:  Stem Cells       Date:  2009-07       Impact factor: 6.277

10.  Amide proton transfer imaging of adult diffuse gliomas: correlation with histopathological grades.

Authors:  Osamu Togao; Takashi Yoshiura; Jochen Keupp; Akio Hiwatashi; Koji Yamashita; Kazufumi Kikuchi; Yuriko Suzuki; Satoshi O Suzuki; Toru Iwaki; Nobuhiro Hata; Masahiro Mizoguchi; Koji Yoshimoto; Koji Sagiyama; Masaya Takahashi; Hiroshi Honda
Journal:  Neuro Oncol       Date:  2013-12-04       Impact factor: 12.300

View more
  3 in total

1.  High-sensitivity CEST mapping using a spatiotemporal correlation-enhanced method.

Authors:  Lin Chen; Suyi Cao; Raymond C Koehler; Peter C M van Zijl; Jiadi Xu
Journal:  Magn Reson Med       Date:  2020-06-29       Impact factor: 4.668

2.  Whole-brain amide CEST imaging at 3T with a steady-state radial MRI acquisition.

Authors:  Ran Sui; Lin Chen; Yuguo Li; Jianpan Huang; Kannie W Y Chan; Xiang Xu; Peter C M van Zijl; Jiadi Xu
Journal:  Magn Reson Med       Date:  2021-03-27       Impact factor: 3.737

Review 3.  A Brief History and Future Prospects of CEST MRI in Clinical Non-Brain Tumor Imaging.

Authors:  Tianxin Gao; Chuyue Zou; Yifan Li; Zhenqi Jiang; Xiaoying Tang; Xiaolei Song
Journal:  Int J Mol Sci       Date:  2021-10-26       Impact factor: 5.923

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.