Literature DB >> 31727305

Brachytherapy Future Directions.

J Adam Martin Cunha1, Ryan Flynn2, Cédric Bélanger3, Cameron Callaghan2, Yusung Kim2, Xun Jia4, Zhe Chen5, Luc Beaulieu3.   

Abstract

Brachytherapy has advanced dramatically in the last decade due largely to improvements in applicators, imaging, treatment planning, and use of clinical trials. In addition, current research in brachytherapy technology continues to change how we deliver this treatment modality. The future of brachytherapy lies in the ability of new technologies to overcome real or perceived barriers. The focus for this manuscript is on specific tools that have or are near to being introduced in the clinic. First, we explore the impact electromagnetic tracking technologies can have on brachytherapy implants and planning workflow. This is followed by an overview of the use of 3D printing and its ability to help tailor brachytherapy implants. Next, we discuss advances in self-shielded applicators and intensity-modulated brachytherapy technology. The manuscript closes out with 2 sections on treatment planning. First is a discussion of biological optimization and its potential as compared with current techniques (eg, based on physical dosimetry). And lastly, a section on optimization treatment planning efficiencies in which we explore the potential for machine learning in brachytherapy. As recent clinical evidence continues to show excellent outcomes, this is an exciting time to practice brachytherapy. With the new technologies presented here, the future is even brighter.
Copyright © 2019. Published by Elsevier Inc.

Mesh:

Year:  2020        PMID: 31727305     DOI: 10.1016/j.semradonc.2019.09.001

Source DB:  PubMed          Journal:  Semin Radiat Oncol        ISSN: 1053-4296            Impact factor:   5.934


  4 in total

Review 1.  Radiation-induced kidney toxicity: molecular and cellular pathogenesis.

Authors:  Richard Klaus; Maximilian Niyazi; Bärbel Lange-Sperandio
Journal:  Radiat Oncol       Date:  2021-02-25       Impact factor: 3.481

2.  Development and pre-clinical test of a phosphorous-32 containing polyetheretherketone foil aiming at urethral stricture prevention by low-dose-rate brachytherapy.

Authors:  Walter Assmann; Ricarda Becker; Christian Stief; Ronald Sroka
Journal:  J Contemp Brachytherapy       Date:  2022-04-02

3.  Commissioning of GPU-based multi-criteria optimizer combined with plan navigation tools for high-dose-rate brachytherapy.

Authors:  Cédric Bélanger; Sylviane Aubin; Luc Beaulieu; Éric Poulin
Journal:  J Contemp Brachytherapy       Date:  2022-08-23

Review 4.  The value of brachytherapy in the age of advanced external beam radiotherapy: a review of the literature in terms of dosimetry.

Authors:  Tibor Major; Georgina Fröhlich; Péter Ágoston; Csaba Polgár; Zoltán Takácsi-Nagy
Journal:  Strahlenther Onkol       Date:  2021-11-01       Impact factor: 3.621

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.