Literature DB >> 31726393

Presence of Legionella spp. in cooling towers: the role of microbial diversity, Pseudomonas, and continuous chlorine application.

Kiran Paranjape1, Émilie Bédard2, Lyle G Whyte1, Jennifer Ronholm3, Michèle Prévost4, Sébastien P Faucher5.   

Abstract

Legionnaires' disease (LD) is a severe pneumonia caused by several species of the genus Legionella, most frequently by Legionella pneumophila. Cooling towers are the most common source for large community-associated outbreaks. Colonization, survival, and proliferation of L. pneumophila in cooling towers are necessary for outbreaks to occur. These steps are affected by the chemical and physical parameters of the cooling tower environment. We hypothesize that the bacterial community residing in the cooling tower could also affect the presence of L. pneumophila. A 16S rRNA gene targeted amplicon sequencing approach was used to study the bacterial community of cooling towers and its relationship with the Legionella spp. and L. pneumophila communities. The results indicated that the water source shaped the bacterial community of cooling towers. Several taxa were enriched and positively correlated with Legionella spp. and L. pneumophila. In contrast, Pseudomonas showed a strong negative correlation with Legionella spp. and several other genera. Most importantly, continuous chlorine application reduced microbial diversity and promoted the presence of Pseudomonas creating a non-permissive environment for Legionella spp. This suggests that disinfection strategies as well as the resident microbial population influences the ability of Legionella spp. to colonize cooling towers.
Copyright © 2019 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  16S rRNA gene targeted amplicon sequencing; Chlorine; Cooling towers; Legionella pneumophila; Microbiome; Pseudomonas

Year:  2019        PMID: 31726393     DOI: 10.1016/j.watres.2019.115252

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  10 in total

Review 1.  Tenets of a holistic approach to drinking water-associated pathogen research, management, and communication.

Authors:  Caitlin Proctor; Emily Garner; Kerry A Hamilton; Nicholas J Ashbolt; Lindsay J Caverly; Joseph O Falkinham; Charles N Haas; Michele Prevost; D Rebecca Prevots; Amy Pruden; Lutgarde Raskin; Janet Stout; Sarah-Jane Haig
Journal:  Water Res       Date:  2021-12-22       Impact factor: 11.236

2.  The Impact of Storms on Legionella pneumophila in Cooling Tower Water, Implications for Human Health.

Authors:  Robin L Brigmon; Charles E Turick; Anna S Knox; Courtney E Burckhalter
Journal:  Front Microbiol       Date:  2020-12-10       Impact factor: 5.640

3.  Unravelling the importance of the eukaryotic and bacterial communities and their relationship with Legionella spp. ecology in cooling towers: a complex network.

Authors:  Kiran Paranjape; Émilie Bédard; Deeksha Shetty; Mengqi Hu; Fiona Chan Pak Choon; Michèle Prévost; Sébastien P Faucher
Journal:  Microbiome       Date:  2020-11-12       Impact factor: 14.650

4.  Is a Proactive Approach to Controlling Legionella in the Environment Justified?

Authors:  Daniela Glažar Ivče; Dobrica Rončević; Marina Šantić; Arijana Cenov; Dijana Tomić Linšak; Vladimir Mićović; Dražen Lušić; Marin Glad; Davor Ljubas; Darija Vukić Lušić
Journal:  Food Technol Biotechnol       Date:  2021-09       Impact factor: 3.918

5.  Enhancing diversity analysis by repeatedly rarefying next generation sequencing data describing microbial communities.

Authors:  Ellen S Cameron; Philip J Schmidt; Benjamin J-M Tremblay; Monica B Emelko; Kirsten M Müller
Journal:  Sci Rep       Date:  2021-11-16       Impact factor: 4.379

6.  Combined utilization of metabolic inhibitors to prevent synergistic multi-species biofilm formation.

Authors:  Dingrong Kang; Wenzheng Liu; Fatemeh Bajoul Kakahi; Frank Delvigne
Journal:  AMB Express       Date:  2022-03-04       Impact factor: 3.298

7.  Bacterial Antagonistic Species of the Pathogenic Genus Legionella Isolated from Cooling Tower.

Authors:  Kiran Paranjape; Simon Lévesque; Sébastien P Faucher
Journal:  Microorganisms       Date:  2022-02-08

Review 8.  Potential probiotic approaches to control Legionella in engineered aquatic ecosystems.

Authors:  Alessio Cavallaro; William J Rhoads; Simona G Huwiler; Elyse Stachler; Frederik Hammes
Journal:  FEMS Microbiol Ecol       Date:  2022-07-28       Impact factor: 4.519

Review 9.  Legionella and Biofilms-Integrated Surveillance to Bridge Science and Real-Field Demands.

Authors:  Ana Pereira; Ana Rosa Silva; Luis F Melo
Journal:  Microorganisms       Date:  2021-06-03

Review 10.  Overview of the Clinical and Molecular Features of Legionella Pneumophila: Focus on Novel Surveillance and Diagnostic Strategies.

Authors:  Giuseppe Gattuso; Roberta Rizzo; Alessandro Lavoro; Vincenzoleo Spoto; Giuseppe Porciello; Concetta Montagnese; Diana Cinà; Alessia Cosentino; Cinzia Lombardo; Maria Lina Mezzatesta; Mario Salmeri
Journal:  Antibiotics (Basel)       Date:  2022-03-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.