Literature DB >> 31724216

Application of Contrast-Enhanced Real-time 3-Dimensional Ultrasound in Solid Abdominal Organ Trauma.

Cong Feng1, Libo Wang2, Sai Huang3, Lili Wang1, Xuan Zhou1, Xiang Cui4, Li Chen1, Faqin Lv2, Tanshi Li1.   

Abstract

OBJECTIVES: To determine whether real-time 3-dimensional ultrasound (RT3DUS) could provide additional information on early detection and evaluation in the management of solid abdominal organ trauma based on an animal model.
METHODS: Nine bleeding lesions were developed in the livers (n = 3), kidneys (n = 3), and spleens (n = 3) from 9 pigs. An ultrasound contrast agent was administered intravenously (liver, 0.025 mL/kg; kidney, 0.008 mL/kg; and spleen, 0.013 mL/kg) after an unenhanced 2-dimensional ultrasound (2DUS) examination (B-mode and color Doppler). After contrast agent injection, bleeding lesions were imaged by 2DUS and sequentially imaged by 3-dimensional static ultrasound (3DSUS) and RT3DUS to identify active bleeding, observe the relationship between bleeding lesions and peripheral blood vessels, and evaluate the spatial scope of the bleeding lesions in the organs.
RESULTS: For the identification of active bleeding, there was no statistical difference in contrast-enhanced 2DUS, 3DSUS, and RT3DUS. For observation of the relationship between bleeding lesions and peripheral blood vessels, RT3DUS performed statistically better than 2DUS (P < .05), as reconstructed RT3DUS could show more information about the relationship. For the evaluation of the spatial scope of the bleeding lesion in the organ, RT3DUS also performed statistically better than 2DUS from the multiplanar observation by postprocessing of the 3-dimensional real-time volumes (P < .05).
CONCLUSIONS: Real-time 3-dimensional ultrasound improves early detection and evaluation of solid abdominal organ trauma and provides additional information over the current contrast-enhanced 2DUS.
© 2019 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  contrast-enhanced ultrasound; early diagnosis; real-time 3-dimensional ultrasound; solid abdominal organ trauma

Mesh:

Substances:

Year:  2019        PMID: 31724216     DOI: 10.1002/jum.15167

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  1 in total

1.  Application of Contrast-Enhanced Ultrasonography (CEUS) in the Assessment of Kidney Wound Recovery After Nephron-Sparing Surgery.

Authors:  Di Niu; Liang Li; Hexi Du; Haoqiang Shi; Jun Zhou; Sheng Tai; Hanjiang Xu; Wei Chen; Cheng Yang; Chaozhao Liang
Journal:  Cancer Manag Res       Date:  2021-05-13       Impact factor: 3.989

  1 in total