Literature DB >> 31723091

Influence of magnetic susceptibility and volume on MRI artifacts produced by low magnetic susceptibility Zr-14Nb alloy and dental alloys.

Yuka Kajima1, Atsushi Takaichi2, Yusuke Tsutsumi3, Takao Hanawa3, Noriyuki Wakabayashi2, Akira Kawasaki1.   

Abstract

The artifact volume generated in magnetic resonance (MR) images was quantitatively evaluated to investigate how artifact behavior correlates to the magnetic susceptibility and volume of an implanted metal device. For this, a new low-magnetic-susceptibility Zr-14Nb alloy was compared with two conventional dental alloys, Ti-6Al-7Nb alloy and Co-Cr-Mo alloy, using spherical specimens of each alloy prepared with four different diameters. Then, MR images were recorded under fast spin echo and gradient echo conditions, from which the artifact volume was measured. The artifact volume decreased with the magnetic susceptibility, volume, and mass of the specimens, and significant linear correlations were observed. The artifact volume can be estimated by the equations presented here; nevertheless, further studies are necessary to interpret the influence of some important factors (e.g., imaging conditions, shape, and orientation) to predict the artifact volume more precisely.

Entities:  

Keywords:  Artifact; Dental alloys; Magnetic resonance imaging (MRI); Magnetic susceptibility; Zr-Nb alloy

Year:  2019        PMID: 31723091     DOI: 10.4012/dmj.2018-426

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  3 in total

1.  Magnetic resonance imaging artefacts caused by orthodontic appliances and/or implant-supported prosthesis: a systematic review.

Authors:  Katrine Mølgaard Johannsen; João Marcus de Carvalho E Silva Fuglsig; Brian Hansen; Ann Wenzel; Rubens Spin-Neto
Journal:  Oral Radiol       Date:  2022-09-30       Impact factor: 1.882

2.  Susceptibility artifacts induced by crowns of different materials with prepared teeth and titanium implants in magnetic resonance imaging.

Authors:  Xiaomeng Gao; Qianbing Wan; Qingping Gao
Journal:  Sci Rep       Date:  2022-01-10       Impact factor: 4.379

3.  Comparison of MRI Visualization Following Minimally Invasive and Open TLIF: A Retrospective Single-Center Study.

Authors:  Vadim A Byvaltsev; Andrei A Kalinin; Morgan B Giers; Valerii V Shepelev; Yurii Ya Pestryakov; Mikhail Yu Biryuchkov
Journal:  Diagnostics (Basel)       Date:  2021-05-19
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.