Literature DB >> 31723088

Diagnostic values of thyroglobulin in lymph node fine-needle aspiration washout: a systematic review and meta-analysis diagnostic values of FNA-Tg.

Xu-Hang Zhu1, Jing-Nan Zhou2, Yang-Yang Qian1, Ke Yang3, Qing-Liang Wen1, Qi-Hong Zhang1, Liang Xia4, Ming-Hua Ge5, Cai-Xing Sun4.   

Abstract

Thyroglobulin measurement in the needle washout after fine-needle aspiration (FNA-Tg) served as an important measurement for suspicious recurrent or metastatic lesions. We conducted a pooled analysis to evaluate the diagnostic accuracy of FNA-Tg and searched electronic databases for original articles in English from 1993 through 2017. Finally, a total of 22 studies containing 2,670 lymph nodes (LNs) that enrolled participants with suspicious neck LNs during thyroid nodule workup or papillary thyroid cancer (PTC) follow-up were included. In our analysis, the overall pooled sensitivity for FNA-Tg was 0.91 (95%CI: 0.87-0.93), specificity was 0.94 (95% CI: 0.91-0.96). Meta regression revealed that the cutoff value and status of serum Tg were sources of heterogeneity for sensitivity, and the cutoff value was source of heterogeneity for specificity. Additionally, the cutoff value and status of serum Tg were sources of heterogeneity in the joint model. Subgroup analysis about cut-off value showed that the choice of 1 ng/mL had highest sensitivity, 40 ng/mL had highest specificity. At last, we arrived at the conclusion that FNA-Tg measurement had high specificity and sensitivity in the early detection of LNs metastases from PTC by our meta-analysis. The technique was simple and could be recommended to apply in any FNA facility, especially when LN were small-sized. Significantly, a better standardization of criteria for FNA-Tg detection and cutoff value was required to provide useful data and to improve management of PTC patients in the future.

Entities:  

Keywords:  Fine-needle aspirate; Lymph node; Meta-analysis; Papillary thyroid carcinoma; Thyroglobulin

Year:  2019        PMID: 31723088     DOI: 10.1507/endocrj.EJ18-0558

Source DB:  PubMed          Journal:  Endocr J        ISSN: 0918-8959            Impact factor:   2.349


  3 in total

1.  Fine Needle Biopsy Versus Core Needle Biopsy Combined With/Without Thyroglobulin or BRAF 600E Mutation Assessment for Detecting Cervical Nodal Metastasis of Papillary Thyroid Carcinoma.

Authors:  Xiaojun Zhang; Xu Zhang; Wei Du; Liyuan Dai; Ruihua Luo; Qigen Fang; Hong Ge
Journal:  Front Endocrinol (Lausanne)       Date:  2021-04-12       Impact factor: 5.555

2.  Value of thyroglobulin combined with ultrasound-guided fine-needle aspiration cytology for diagnosis of lymph node metastasis of thyroid carcinoma.

Authors:  Liu-Yang Zhang; Yong Chen; Ya-Zhou Ao
Journal:  World J Clin Cases       Date:  2022-01-14       Impact factor: 1.337

3.  Fine-needle Aspiration Washout Precipitation Specimens: An Acceptable Supplement to Genetic Mutation Detection of Thyroid Nodules.

Authors:  Yongmei Cui; Xiangqi Huang; Jinrui Guo; Nana Zhang; Jing Liang; Yiwang Zhang; Yueting Liao; Dan He
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.