Literature DB >> 31721960

The usefulness of Tanita TBF-310 for body composition assessment in Judo athletes using a four-compartment molecular model as the reference method.

Christophe Domingos1, Catarina Nunes Matias1, Edilson Serpeloni Cyrino2, Luís Bettencourt Sardinha1, Analiza Mónica Silva1.   

Abstract

Body composition assessment at the molecular level is relevant for the athletic population and its association with high performance is well recognized. The four-compartment molecular model (4C) is the reference method for fat mass (FM) and fat-free mass (FFM) estimation. However, its implementation in a real context is not feasible. Coaches and athletes need practical body composition methods for body composition assessment, and the bioelectrical impedance analysis method (BIA) is usually seen as a useful alternative. The aim of this study was to test the validity of BIA (Tanita, TBF-310) to determine the FM and FFM of elite judo athletes. A total of 29 males were evaluated in a period of weight stability using the reference method (4C) and the alternative method (Tanita, TBF-310). Regarding the 4C method, total-body water was assessed by deuterium dilution, bone mineral by DXA, and body volume by air displacement plethysmography. The slops and intercepts differed from 1 (0.39 and 1.11) and 0 (4.24 and -6.41) for FM and FFM, respectively. FM from Tanita TBF-310 overestimated the 4C method by 0.2 kg although no differences were found for FFM. Tanita TBF-310 explained 21% and 72% respectively in the estimation of absolute values of FM and FFM from the 4C method. Limits of agreement were significant, varying from -6.7 kg to 7.0 kg for FM and from -8.9 kg to 7.5 kg for FFM. In conclusion, TBF-310 Tanita is not a valid alternative method for estimating body composition in highly trained judo athletes.

Entities:  

Mesh:

Year:  2019        PMID: 31721960     DOI: 10.1590/1806-9282.65.10.1283

Source DB:  PubMed          Journal:  Rev Assoc Med Bras (1992)        ISSN: 0104-4230            Impact factor:   1.209


  3 in total

1.  Bioelectrical impedance analysis versus reference methods in the assessment of body composition in athletes.

Authors:  Francesco Campa; Luis Alberto Gobbo; Silvia Stagi; Leticia Trindade Cyrino; Stefania Toselli; Elisabetta Marini; Giuseppe Coratella
Journal:  Eur J Appl Physiol       Date:  2022-01-24       Impact factor: 3.078

2.  Mediterranean Diet Adherence, Body Composition and Performance in Beach Handball Players: A Cross Sectional Study.

Authors:  Alejandro Martínez-Rodríguez; María Martínez-Olcina; María Hernández-García; Jacobo Á Rubio-Arias; Javier Sánchez-Sánchez; Daniel Lara-Cobos; Manuel Vicente-Martínez; Maria José Carvalho; Juan Antonio Sánchez-Sáez
Journal:  Int J Environ Res Public Health       Date:  2021-03-10       Impact factor: 3.390

Review 3.  Assessment of Body Composition in Athletes: A Narrative Review of Available Methods with Special Reference to Quantitative and Qualitative Bioimpedance Analysis.

Authors:  Francesco Campa; Stefania Toselli; Massimiliano Mazzilli; Luís Alberto Gobbo; Giuseppe Coratella
Journal:  Nutrients       Date:  2021-05-12       Impact factor: 6.706

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.