[Clinical and functional outcomes of correcting low to moderate myopia with FemtoLASIK performed with Russian and Swiss femtolaser platforms].

A V Doga1, I A Mushkova1, A N Karimova1, E V Kechin1.   

Abstract

PURPOSE: To compare the effectiveness, safety, predictability and stability of FemtoLASIK procedure in low to moderate myopia using Femto Visum and Femto LDV Z6 femtosecond laser platforms and to evaluate the effect of these procedures on corneal higher-order aberrations.
MATERIAL AND METHODS: Russian femtolaser platform (1 MHz) was used to form the corneal flap in the main group consisting of 98 patients (98 eyes) with mean spherical equivalent (SE) of -3.73±1.42 D. Swiss femtolaser platform (5 MHz) was used in the control group (94 patients, 94 eyes; mean SE -3.81±1.44 D). Excimer laser ablation was performed using the Russian platform (500 Hz) in both groups. All patients underwent complete ophthalmological examination. The follow-up period was 12 months.
RESULTS: Twelve month postoperatively, in the '1 MHz' group uncorrected visual acuity (UCVA) of 1.0 or better was achieved in 91.8% of patients, and in the '5 MHz' group - in 90.4% (p>0.05). There were no registered losses of 2 or more lines of best-corrected visual acuity (BCVA) in either group. In the '1 MHz' group, predictability of targeted refraction within ±0.5 D was achieved in 91.8% of patients, within ±1.0 D - in 99.0%; in the '5 MHz' group - in 91.5% and 98.9% of patients, respectively (p>0.05). Root-mean-square (RMS) deviation of corneal higher-order aberrations in the 6-mm optical zone was increased by 0.072 μm (by 1.21 times) and by 0.077 μm (by 1.22 times) in the '1 MHz' and '5 MHz' groups (p>0.05), respectively.
CONCLUSION: The FemtoLASIK procedures performed using Russian (1 MHz) and Swiss (5 MHz) femtosecond laser platforms are effective, safe, predictable, have stable postoperative visual and refractive outcomes, and lead to increase in RMS of corneal higher-order aberrations using both platforms in patients with low to moderate myopia. There were no statistically significant differences between the two femtolaser platforms (p>0.05) for all examined parameters.

Entities:  

Keywords:  Femto LDV Z6; Femto Visum; FemtoLASIK; femtosecond laser; myopia

Mesh:

Year:  2019        PMID: 31714508     DOI: 10.17116/oftalma201913505113

Source DB:  PubMed          Journal:  Vestn Oftalmol        ISSN: 0042-465X


  1 in total

Review 1.  Mitomycin C application after photorefractive keratectomy in high, moderate, or low myopia: Systematic review and meta-analysis.

Authors:  Yassamine Ouerdane; Mohamed Sayed Zaazouee; Moaiad Eldin Ahmed Mohamed; Mohammed Tarek Hasan; Mohamed Hamdy; Abdallah Magdy Ghoneim; Mohamed Ibrahim Gbreel; Ahmed Mohamed Ibrahim; Khaled Mohamed Ragab; Anas Zakarya Nourelden
Journal:  Indian J Ophthalmol       Date:  2021-12       Impact factor: 1.848

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.