Fracture force of CAD/CAM resin composite crowns after in vitro aging.

Martin Rosentritt1, Stefanie Krifka2, Thomas Strasser2, Verena Preis2.   

Abstract

OBJECTIVES: The aim of this in vitro study was to investigate the influence of material, preparation, and pre-treatment on the aging and fracture force of CAD/CAM resin composite molar crowns.
MATERIALS AND METHODS: CAD/CAM molar crowns (n = 80) were milled from four resin composites (Block HC, Shofu; Lava Ultimate, 3 M; Grandio Blocs, Voco; and Tetric CAD, Ivoclar Vivadent, with/without sandblasting). Extracted human teeth were prepared with optimal preparation (height 6-8 mm, angle 6-8°) or worst-case preparation (height 3.5-4 mm, angle 10-15°). Both groups were prepared with a 1-mm deep cervical circular shoulder. Crowns were adhesively bonded after corresponding tooth treatment required for the individual adhesive systems (Table 1). Specimens were aged for 90 days in water storage (37 °C) and subsequently subjected to thermal cycling and mechanical loading (TCML 3000 × 5 °C/3000 × 55 °C, 2 min each cycle, H20 distilled; 1.2 × 106 cycles à 50 N, 1.6 Hz). De-bonding and fracture force was determined. STATISTICS: one-way-ANOVA; post hoc Bonferroni, α = 0.05.
RESULTS: Four crowns of Lava Ultimate with worst-case preparation de-bonded during TCML. Individual crowns without sandblasting treatment (3x Tetric CAD with optimal preparation; 1x Tetric CAD with worst-case preparation) de-bonded during water storage. One crown of Grandio Blocs with optimal preparation showed a small chipping during TCML. All other crowns survived TCML and water storage without failure. Fracture forces differed between 1272 ± 211 N (Lava Ultimate) and 3061 ± 521 N (Tetric CAD). All Grandio Blocs and Tetric CAD crowns revealed significantly (p ≤ 0.023) higher fracture forces than Block HC or Lava Ultimate crowns. No significantly different (p > 0.05) fracture forces were found between optimal or worst-case preparation/fit groups.
CONCLUSIONS: De-bonding during water storage and TCML was dependent on material and crown pre-treatment. Therefore, surface roughening seems strongly required. Fracture forces were not influenced by preparation but by the type of material. CLINICAL RELEVANCE: Clinical success and de-bonding of CAD/CAM resin composite crowns is strongly influenced by the type of material and its pre-treatment.

Entities:  

Keywords:  Aging; CAD/CAM; CAD/CAM bloc; Dental material; Fit; Preparation; Resin composite; Resin-based material; Storage; TCML

Year:  2019        PMID: 31712983     DOI: 10.1007/s00784-019-03099-1

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  4 in total

1.  Clinical acceptability of PEEK fixed dental prosthesis in partially edentulous patient - A one year single arm pilot study.

Authors:  D Arun Raj; Naveen Gopi Chander; Jetti Ramesh Reddy; Muthukumar Balasubramaniam
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-18

2.  An Interdisciplinary Study Regarding the Characteristics of Dental Resins Used for Temporary Bridges.

Authors:  Ioana Mârțu; Alice Murariu; Elena Raluca Baciu; Carmen Nicoleta Savin; Iolanda Foia; Monica Tatarciuc; Diana Diaconu-Popa
Journal:  Medicina (Kaunas)       Date:  2022-06-16       Impact factor: 2.948

3.  Effect of Thermocycling on Color, Surface Characteristics, Compressive Fracture, and Fracture Modes of Prosthetic CAD/CAM Ceramics After Smokeless Tobacco Immersion.

Authors:  Saeed M Alqahtani
Journal:  Med Sci Monit       Date:  2022-05-29

4.  Impact of the Veneering Technique and Framework Material on the Failure Loads of All-Ceramic Computer-Aided Design/Computer-Aided Manufacturing Fixed Partial Dentures.

Authors:  Sebastian Hinz; Tobias Bensel; Wolfgang Bömicke; Anders Henningsen; Judith Rudolph; Arne F Boeckler
Journal:  Materials (Basel)       Date:  2022-01-19       Impact factor: 3.623

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.