Literature DB >> 31711244

The FUSION iENA Study: Comparison of I-124-PET/US Fusion Imaging with Conventional Diagnostics for the Functional Assessment of Thyroid Nodules by Multiple Observers.

Thomas Winkens1, Philipp Seifert1, Christian Hollenbach1, Christian Kühnel1, Falk Gühne1, Martin Freesmeyer1.   

Abstract

AIM: To investigate the value of I-124 positron emission tomography (PET) / ultrasound (US) fusion imaging in comparison to conventional diagnostics (CD) of Thyroid nodules (TN) by multiple observers.
METHODS: Digital patient case files (PCF) of patients that received CD and I-124-PET/US in clinical routine were prepared containing cine-loops of the examinations. All physicians with nuclear medicine specialty from Germany, Austria, and Switzerland were invited to participate. 106 acquired observers completed 7.2 ± 1.8 (median: 8, range: 4-14) randomly assigned PCF (CD only or CD+PET/US). They assessed the TN function, stated their confidence in functional assessment, and suggested a treatment course for each TN.
RESULTS: 68 PCF of 34 patients comprising 66 TN ≥ 1 cm (= 1.94 TN/patient) were created. A total of 748 (11.2/TN), and 751 ratings (11.4/TN) were recorded for CD only, and CD+PET/US, respectively. The functional assessment revealed more hyper- or hypofunctioning (524 vs. 320, p < 0.0001) and less indifferent or not rateable (209 vs. 428, p < 0.0001) TN in CD+PET/US vs. CD only. The observers' confidence in functional assessment was superior in CD+PET/US (p < 0.0001). Furthermore, the ratings were carried out more homogeneous in CD+PET/US (p < 0.0001). Fewer suggestion of follow up (p < 0.0001), and more (p < 0.0001) suggestion of invasive treatments (fine-needle aspiration & surgery) was observed in CD+PET/US. Radioiodine therapy was more often (p = 0.0036), and thyroid medication less often (p = 0.0167) advised in CD+PET/US.
CONCLUSION: Functional assessment of equivocal TN shows frequent failures in CD, underestimating the incidence of hyper- and hypofunctioning lesions. Confidence in functional assessment significantly increases with additional PET/US. This influences the proposed treatment course. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31711244     DOI: 10.1055/a-1031-9832

Source DB:  PubMed          Journal:  Nuklearmedizin        ISSN: 0029-5566            Impact factor:   1.379


  3 in total

1.  Fusion iENA Scholar Study: Sensor-Navigated I-124-PET/US Fusion Imaging versus Conventional Diagnostics for Retrospective Functional Assessment of Thyroid Nodules by Medical Students.

Authors:  Martin Freesmeyer; Thomas Winkens; Luis Weissenrieder; Christian Kühnel; Falk Gühne; Simone Schenke; Robert Drescher; Philipp Seifert
Journal:  Sensors (Basel)       Date:  2020-06-17       Impact factor: 3.576

2.  Ultrasound Cine Loop Standard Operating Procedure for Benign Thyroid Diseases-Evaluation of Non-Physician Application.

Authors:  Philipp Seifert; Ivonne Maikowski; Thomas Winkens; Christian Kühnel; Falk Gühne; Robert Drescher; Martin Freesmeyer
Journal:  Diagnostics (Basel)       Date:  2021-01-04

3.  Multimodal Characterization of a PSMA-Positive Thyroid Nodule Using 68Ga-PSMA and 124Iodine PET/US Fusion Imaging.

Authors:  Martin Freesmeyer; Falk Gühne; Robert Drescher; Thomas Winkens; Nikolaus Gassler; Philipp Seifert
Journal:  Diagnostics (Basel)       Date:  2022-02-12
  3 in total