Literature DB >> 31711084

Effect of Different Framework Materials in Implant-Supported Fixed Mandibular Prostheses: A Finite Element Analysis.

Diego Sirandoni, Eduardo Leal, Benjamin Weber, Pedro Yoshito Noritomi, Ramón Fuentes, Eduardo Borie.   

Abstract

PURPOSE: To evaluate the biomechanical behaviors of different framework materials in implant-supported fixed mandibular prostheses using three-dimensional (3D) finite element analysis.
MATERIALS AND METHODS: A model of a severely resorbed edentulous mandible was obtained from a tomography database. Morse taper-connection implants and multi-unit abutments were cut with an electro-erosion machine and scanned using a 3D scanner. The implants were positioned on the model at the bone level and distributed equally to support a fixed complete prosthesis. The simulations were divided into six groups according to the framework material: titanium (Ti); cobalt-chromium (Co-Cr); zirconia (ZrO2); polyether ether ketone (PEEK); carbon fiber-reinforced polyether ether ketone (CFR-PEEK); and polymethyl methacrylate (PMMA). The resultant load applied was obtained from the masseter, temporal, lateral, and medial pterygoid muscles. The principal stresses and von Mises equivalent stresses were analyzed and compared among the framework materials, and the results were described both quantitatively and qualitatively.
RESULTS: PEEK and PMMA frameworks showed the highest total deformation values, showing decreases of von Mises stresses in the frameworks, implants, and abutments, but with a high tensile stress in the trabecular bone that achieved critical values. CFR-PEEK frameworks achieved their failure limit, whereas the ZrO2, Co-Cr, and Ti frameworks exhibited principal stresses in the bone region within physiologic limits.
CONCLUSION: From a biomechanical point of view, the Ti, Co-Cr, and ZrO2 frameworks demonstrated the most favorable outcomes.

Entities:  

Mesh:

Substances:

Year:  2019        PMID: 31711084     DOI: 10.11607/jomi.7255

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

Review 1.  New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Authors:  Pinar Cevik; Martin Schimmel; Burak Yilmaz
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

2.  The effects of reinforcement with nanoparticles of polyetheretherketone, zirconium oxide and its mixture on flexural strength of PMMA resin.

Authors:  Deepali Barapatre; Surabhi Somkuwar; Sunil Kumar Mishra; Ramesh Chowdhary
Journal:  Eur Oral Res       Date:  2022-05-05

3.  Technical and Biological Complications of Screw-Retained (CAD/CAM) Monolithic and Partial Veneer Zirconia for Fixed Dental Prostheses on Posterior Implants Using a Digital Workflow: A 3-Year Cross-Sectional Retrospective Study.

Authors:  Paolo De Angelis; Giulio Gasparini; Francesca Camodeca; Silvio De Angelis; Margherita Giorgia Liguori; Edoardo Rella; Francesca Cannata; Antonio D'Addona; Paolo Francesco Manicone
Journal:  Biomed Res Int       Date:  2021-07-06       Impact factor: 3.411

Review 4.  The use of PEEK in digital prosthodontics: A narrative review.

Authors:  Ioannis Papathanasiou; Phophi Kamposiora; George Papavasiliou; Marco Ferrari
Journal:  BMC Oral Health       Date:  2020-08-02       Impact factor: 2.757

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.