Literature DB >> 31710204

Cellulose-Based Strips Designed Based on a Sensitive Enzyme Colorimetric Assay for the Low Concentration of Glucose Detection.

Xiaogang Luo1,2, Jian Xia1, Xiangyang Jiang1, Mengru Yang1, Shilin Liu3.   

Abstract

High-purity cellulose membranes prepared via a green pathway were used to attempt to enhance their performance of glucose detection compared with that of traditional filter paper. In this work, cellulose-based strips (CBS) for the low concentration of glucose detection have been designed based on a fast, sensitive, and easy enzyme colorimetric assay from porous and high-purity cellulose membranes (CM). Different from the traditional paper-based sensors that were made of commercially available filter paper, the cellulose-based membranes matrix was fabricated by a "green" route in that cellulose was dissolved in an aqueous NaOH/urea solution, and then modified by the sodium periodate oxidation method to immobilize the glucose oxidase (GOX) and horseradish peroxidase (HRP) with Schiff-base reaction. The structure and properties of CM and CBS were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray mapping (EDS), Fourier-transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), etc. SEM images showed a porous, interpenetrating structure of CM, which benefited the enzyme immobilization and enzymatic reaction. When glucose solution was dropped onto the CBS, the color change from colorless to blue was only 5 min. The limit of detection (LOD) is 0.45 mM in the linear range of glucose from 1 to 11 mM. Moreover, the CBS had also been successfully used for glucose determination in real urine samples, and the color changes can be easily recorded by a simple camera to achieve the semiquantitative detection of glucose. This work provided a new design strategy for the cellulose-based functional materials which could be applied in biosensors, drug carriers, and biomedicine.

Entities:  

Year:  2019        PMID: 31710204     DOI: 10.1021/acs.analchem.9b03180

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  8 in total

1.  Sample-to-Answer Robotic ELISA.

Authors:  Chuqing Zhou; Zecong Fang; Cunyi Zhao; Xiyan Mai; Shiva Emami; Ameer Y Taha; Gang Sun; Tingrui Pan
Journal:  Anal Chem       Date:  2021-08-11       Impact factor: 8.008

2.  An Ultrasensitive and Selective Determination of Cadmium Ions at ppt Level Using an Enzymic Membrane with Colorimetric and Electrochemical Detection.

Authors:  Raouia Attaallah; Aziz Amine
Journal:  Biosensors (Basel)       Date:  2022-05-07

3.  A novel metal-organic framework of Ba-hemin with enhanced cascade activity for sensitive glucose detection.

Authors:  Jintao Yi; Xianqin Han; Fengying Gao; Le Cai; Ying Chen; Xiulong Deng; Xun Li; Jun Xue; Hui Zhou
Journal:  RSC Adv       Date:  2022-07-15       Impact factor: 4.036

Review 4.  Recent Advances in Cellulose-Based Biosensors for Medical Diagnosis.

Authors:  Samir Kamel; Tawfik A Khattab
Journal:  Biosensors (Basel)       Date:  2020-06-17

5.  pH-Responsive Cellulose-Based Microspheres Designed as an Effective Oral Delivery System for Insulin.

Authors:  Yaqi Gong; Shabbir Mohd; Simei Wu; Shilin Liu; Ying Pei; Xiaogang Luo
Journal:  ACS Omega       Date:  2021-01-25

6.  Thermal Detection of Glucose in Urine Using a Molecularly Imprinted Polymer as a Recognition Element.

Authors:  Manlio Caldara; Joseph W Lowdon; Renato Rogosic; Rocio Arreguin-Campos; Kathia L Jimenez-Monroy; Benjamin Heidt; Kristina Tschulik; Thomas J Cleij; Hanne Diliën; Kasper Eersels; Bart van Grinsven
Journal:  ACS Sens       Date:  2021-11-26       Impact factor: 7.711

Review 7.  Recent advances in cellulose-based membranes for their sensing applications.

Authors:  Jiang Fan; Sufeng Zhang; Fei Li; Yonglin Yang; Min Du
Journal:  Cellulose (Lond)       Date:  2020-09-11       Impact factor: 5.044

Review 8.  Current Challenges and Future Trends of Enzymatic Paper-Based Point-of-Care Testing for Diabetes Mellitus Type 2.

Authors:  Margarita Ortiz-Martínez; Raquel Flores-DelaToba; Mirna González-González; Marco Rito-Palomares
Journal:  Biosensors (Basel)       Date:  2021-11-27
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.