Literature DB >> 31708555

Second-Generation Visually Guided Laser Balloon Ablation System for Pulmonary Vein Isolation: Learning Curve, Safety and Efficacy - The MERLIN Registry.

Christian-H Heeger1,2, Huong-Lan Phan1, Roza Meyer-Saraei1, Thomas Fink1, Vanessa Sciacca1, Spyridon Liosis1, Ben Brüggemann1, Niels Große1, Bezhad Fahimi1, Makoto Sano1,3, Karl-Heinz Kuck1, Feifan Ouyang4, Julia Vogler1, Charlotte Eitel1, Roland Richard Tilz1,2.   

Abstract

BACKGROUND: Radiofrequency (RF)-based pulmonary vein isolation (PVI) results in a favorable clinical outcome, although its complexity demands a long learning curve. Balloon-based systems have been developed to possibly solve these limitations. The 2nd-generation laser balloon (LB2) offers optimized features for improved tissue contact and visibility. We determined the safety, efficacy and learning curve of the LB2 for PVI.Methods and 
Results: A total of 45 consecutive patients (89% persistent AF) were prospectively enrolled and divided into 3 groups (T1, T2, T3) of n=15 patients per group. All patients underwent PVI by 2 operators using the LB2. The operators were experienced in RF and cryothermal procedures, but not in laser ablations. A total of 174/177 PVs (98%) were successfully isolated. The median procedure time significantly declined from 132 (114, 158) to 119 (102, 127) and 91 (86, 105) min in T1-3, respectively (P=0.0009). Similarly, the median fluoroscopy time significantly decreased from T1 to T3 (22 (17, 27) vs. 21 (16, 24) vs. 13 (10, 17) min, respectively, P=0.045). Adverse events occurred in 6.7%, with a trend towards a lower complication rate with increasing experience.
CONCLUSIONS: The LB2 was safe and effective for PVI, even for operators without any previous experience in laser balloon-based PVI. Procedure time, left atrial dwelling time and fluoroscopy time decreased after a learning curve of 15 cases.

Entities:  

Keywords:  Atrial fibrillation; Catheter ablation; Laser balloon; Learning curve; Pulmonary vein isolation

Year:  2019        PMID: 31708555     DOI: 10.1253/circj.CJ-19-0766

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  5 in total

1.  Evaluation of different ablation strategies verifying the optimal overlap ratio in point-by-point laser balloon ablation for patients with atrial fibrillation.

Authors:  Takahiko Nagase; Ruiko Seki; So Asano; Hiroshi Fukunaga; Kazuhiro Terashima; Kei Mabuchi; Kanki Inoue; Kohei Tanizaki; Nobuo Iguchi; Junichi Nitta; Mitsuaki Isobe
Journal:  Heart Rhythm O2       Date:  2021-07-02

2.  Rapid pulmonary vein isolation utilizing the third-generation laserballoon - The PhoeniX registry.

Authors:  Christian-H Heeger; Christian M Tiemeyer; Huong-Lan Phan; Roza Meyer-Saraei; Thomas Fink; Vanessa Sciacca; Spyridon Liosis; Ben Brüggemann; Niels Große; Bezhad Fahimi; Samuel Reincke; Karl-Heinz Kuck; Feifan Ouyang; Julia Vogler; Charlotte Eitel; Roland R Tilz
Journal:  Int J Cardiol Heart Vasc       Date:  2020-07-03

3.  Comparison of procedural outcomes in patients undergoing catheter vs surgical ablation for atrial fibrillation and heart failure with reduced ejection fraction.

Authors:  Rajkumar Doshi; Ashish Kumar; Mariam Shariff; Devina Adalja; Krunalkumar Patel; Kirtenkumar Patel; Rupak Desai; Nageshwara Gullapalli; Saraschandra Vallabhajosyula
Journal:  J Arrhythm       Date:  2020-11-23

4.  Evaluation of linear lesion formation and thermodynamics by dragging ablation with the third-generation laser balloon.

Authors:  Takahiko Nagase; So Asano; Hiroshi Fukunaga; Yuhei Kasai; Kanki Inoue; Yukio Sekiguchi; Kohei Tanizaki; Tatsuya Murai; Mamoru Nanasato; Jun Umemura; Junichi Nitta; Mitsuaki Isobe
Journal:  Heart Rhythm O2       Date:  2022-04-15

5.  Early experiences with three types of balloon-based ablation catheters in patients with paroxysmal atrial fibrillation.

Authors:  Atsushi Kobori; Yasuhiro Sasaki; Misun Pak; Taiji Okada; Toshiaki Toyota; Kitae Kim; Takeshi Kitai; Natsuhiko Ehara; Makoto Kinoshita; Shuichiro Kaji; Yasuki Kihara; Yutaka Furukawa
Journal:  Heart Rhythm O2       Date:  2021-03-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.