Literature DB >> 31705696

Superb Microvascular Imaging in the Evaluation of Pediatric Graves Disease and Hashimoto Thyroiditis.

Zuhal Bayramoglu1, Sedat Giray Kandemirli2, Zeynep Nur Akyol Sarı1, Aslı Derya Kardelen3, Sukran Poyrazoglu3, Firdevs Bas3, Feyza Darendeliler3, Ibrahim Adaletli4.   

Abstract

OBJECTIVES: We aimed to investigate the differences between spectral Doppler and Superb Microvascular Imaging (SMI; Canon Medical Systems, Tokyo, Japan) findings in children with Hashimoto thyroiditis (HT) and Graves disease (GD) compared to healthy control participants.
METHODS: The study included 34 patients with GD, 37 patients with HT, and 22 healthy volunteers. All patients with HT and 11 patients with GD were euthyroid; 23 patients with GD had symptoms of hyperthyroidism and had thyrotropin values of less than 0.5 mIU/L. Thyroid volumes, mean resistive indices, and peak systolic velocities along with vascularity indices (VIs) on Superb Microvascular Imaging were measured.
RESULTS: Patients with GD had a significantly higher mean thyroid volume (P < .001; right lobe, 11.80 mL; left lobe, 9.10 mL) and peak systolic velocity (right, 32.5 cm/s; left, 30 cm/s) with a lower resistive index (right, 0.48%; left, 0.48%) compared to patients with HT (right, 8.78 mL, 20 cm/s, 0.55%; left, 7.41 mL, 20 cm/s, 0.55%, respectively) and also control participants (right, 4.59 mL, 15 cm/s, 0.56%; left, 3.52 mL, 15 cm/s, 0.54%). Patients with GD had a significantly higher median VI (right, 25%; left, 26%) compared to patients with HT (right, 11%; left, 13%) and control participants (right, 8%; left, 8%). When patients with GD were categorized as euthyroid and hyperthyroid based on thyrotropin levels and clinical symptoms, both euthyroid and hyperthyroid patients with GD had significantly higher thyroid volumes compared to patients with HT (P < .001). Hyperthyroid patients with GD had higher thyroid volumes compared to euthyroid patients with GD; however, the difference failed to reach statistical significance. A significant strong positive correlation with the VI and thyrotropin receptor autoantibody levels (r = 0.696) was found. The highest area under the curve was obtained for the right lobe VI (0.885), followed by the left lobe VI (0.872), right lobe volume (0.828), and peak systolic velocity (0.810). The optimal cutoff VI value for distinguishing between HT and GD was 17.35% with sensitivity, specificity, and diagnostic accuracy of 85.3%, 78.4%, and 81.7%, respectively.
CONCLUSIONS: Superb Microvascular Imaging is a new method that can detect subtle vascularity changes with higher accuracy compared to spectral Doppler parameters in distinguishing between HT and GD.
© 2019 by the American Institute of Ultrasound in Medicine.

Entities:  

Keywords:  Graves disease; Hashimoto thyroiditis; Superb microvascular imaging; chronic autoimmune thyroiditis; color Doppler; vascularity index

Mesh:

Year:  2019        PMID: 31705696     DOI: 10.1002/jum.15171

Source DB:  PubMed          Journal:  J Ultrasound Med        ISSN: 0278-4297            Impact factor:   2.153


  4 in total

1.  The Role of Superb Microvascular Imaging and Shear Wave Elastography in Differentiation of Thyroid Nodules from Intrathyroidal Ectopic Thymus in Children.

Authors:  I Ihezagire; Z Bayramoglu; Y E Akpinar; I Adaletli
Journal:  Acta Endocrinol (Buchar)       Date:  2021 Apr-Jun       Impact factor: 0.877

2.  Diagnostic accuracy of ultrasound superb microvascular imaging for parotid tumors: A protocol for systematic review and meta-analysis.

Authors:  Jili Zhang; Jialing Wu; Xiukun Hou
Journal:  Medicine (Baltimore)       Date:  2021-01-29       Impact factor: 1.817

3.  Evaluation of parenchymal vascularity of the thyroid gland with vascularization index by color superb microvascular imaging in patients with Graves' disease.

Authors:  Abidin Kılınçer; Mehmet Sedat Durmaz; Cem Onur Kıraç; Süleyman Baldane; Fatih Ateş; Abdüssamet Batur
Journal:  J Ultrason       Date:  2021-03-08

4.  The comparative study of color doppler flow imaging, superb microvascular imaging, contrast-enhanced ultrasound micro flow imaging in blood flow analysis of solid renal mass.

Authors:  Yiran Mao; Jie Mu; Jing Zhao; Fan Yang; Lihui Zhao
Journal:  Cancer Imaging       Date:  2022-05-03       Impact factor: 3.909

  4 in total