Characterization of standardized breath sampling for off-line field use.

Sean W Harshman1, Rhonda L Pitsch, Christina N Davidson, Alexander M Scott, Elizabeth M Hill, Zachary K Smith, Kraig E Strayer, Nicole M Schaeublin, Taylor L Wiens, Michael C Brothers, Grant M Slusher, Megan L Steele, Brian A Geier, Maomian Fan, Leslie A Drummond, Jennifer A Martin.   

Abstract

Due to several sources of potential variability associated with exhaled breath bag sampling procedures for off-line analysis, the Respiration Collector for in vitro Analysis (ReCIVA) sampler was developed. Although designed to improve upon several pitfalls of sampling with exhaled breath bags, the ReCIVA remains a minimally studied research tool. In this manuscript, several attributes of the ReCIVA sampler are investigated among three individual tests, such as background contamination, control software version, performance of different adsorbent tubes, duplicate sample production, and comparison to exhaled breath bags. The data shows greater than a 58% reduction in background siloxanes can be achieved with submersion of ReCIVA masks in ethyl alcohol or baking the masks at a high temperature (200 °C). The results illustrate the ReCIVA control software version plays a key role in the flow rates applied to thermal desorption (TD) tubes. Using exhaled isoprene as a representative analyte, the data suggest duplicate samples among ReCIVA pump banks can be achieved using two different thermal desorption tubes, Tenax TA and Tenax/Carbograph 5TD, when using an updated control software and manually calibrating the ReCIVA pumps to uniform flow rates (Tenax p = 0.3869, 5TD p = 0.3131). Additionally, using the updated control software and manual ReCIVA flow calibration, the data suggest the ReCIVA can produce statistically similar results among TD tube types (p = 0.3824) and compared to standard exhaled breath bags (p = 0.1534). Collectively, these results establish a method for manually calibrating the flow of the ReCIVA device to allow for the most consistent results. These data support further experimentation into the use of the ReCIVA sampler for exhaled breath research.

Entities:  

Year:  2019        PMID: 31703231     DOI: 10.1088/1752-7163/ab55c5

Source DB:  PubMed          Journal:  J Breath Res        ISSN: 1752-7155            Impact factor:   3.262


  5 in total

1.  Selected ion flow tube mass spectrometry for targeted analysis of volatile organic compounds in human breath.

Authors:  Ilaria Belluomo; Piers R Boshier; Antonis Myridakis; Bhamini Vadhwana; Sheraz R Markar; Patrik Spanel; George B Hanna
Journal:  Nat Protoc       Date:  2021-06-04       Impact factor: 13.491

2.  Breath Analysis: Comparison among Methodological Approaches for Breath Sampling.

Authors:  Alessia Di Gilio; Jolanda Palmisani; Gianrocco Ventrella; Laura Facchini; Annamaria Catino; Niccolò Varesano; Pamela Pizzutilo; Domenico Galetta; Massimo Borelli; Pierluigi Barbieri; Sabina Licen; Gianluigi de Gennaro
Journal:  Molecules       Date:  2020-12-10       Impact factor: 4.411

3.  Micro-Chamber/Thermal Extractor (µ-CTE) as a new sampling system for VOCs emitted by feces.

Authors:  Ileana Andreea Ratiu; Radik Mametov; Tomasz Ligor; Bogusław Buszewski
Journal:  Sci Rep       Date:  2021-09-21       Impact factor: 4.379

4.  3D-printed mouthpiece adapter for sampling exhaled breath in medical applications.

Authors:  Y Lan Pham; Jonathan Beauchamp; Alexander Clement; Felix Wiegandt; Olaf Holz
Journal:  3D Print Med       Date:  2022-08-09

5.  Variation of volatile organic compound levels within ambient room air and its impact upon the standardisation of breath sampling.

Authors:  Michael Jonathan Hewitt; Ilaria Belluomo; Simone Zuffa; Piers R Boshier; Antonis Myridakis
Journal:  Sci Rep       Date:  2022-09-23       Impact factor: 4.996

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.